The CMS Event Builder

Abstract

The data acquisition system of the CMS experiment at the Large Hadron Collider will employ an event builder which will combine data from about 500 data sources into full events at an aggregate throughput of 100 GByte/s. Several architectures and switch technologies have been evaluated for the DAQ Technical Design Report by measurements with test benches and by simulation. This paper describes studies of an EVB test-bench based on 64 PCs acting as data sources and data consumers and employing both Gigabit Ethernet and Myrinet technologies as the interconnect. In the case of Ethernet, protocols based on Layer-2 frames and on TCP/IP are evaluated. Results from ongoing studies, including measurements on throughput and scaling are presented. The architecture of the baseline CMS event builder will be outlined. The event builder is organised into two stages with intelligent buffers in between. The first stage contains 64 switches performing a first level of data concentration by building super-fragments from fragments of 8 data sources. The second stage combines the 64 super-fragments into full events. This architecture allows installation of the second stage of the event builder in steps, with the overall throughput scaling linearly with the number of switches in the second stage. Possible implementations of the components of the event builder are discussed and the expected performance of the full event builder is outlined.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V. Brigljevic, G. Bruno, E. Cano, S. Cittolin, A. Csilling, D. Gigi, F. Glege, R. Gomez-Reino, M. Gulmini, J. Gutleber, C. Jacobs, M. Kozlovszky, H. Larsen, I. Magrans de Abril, F. Meijers, E. Meschi, S. Murray, A. Oh, L. Orsini, L. Pollet, A. Racz, D. Samyn, P. Scharff-Hansen, C. Schwick, P. Sphicas, V. ODell, I. Suzuki, L. Berti, G. Maron, N. Toniolo, L. Zangrando, A. Ninane, S. Erhan, S. Bhattacharya, J. Branson. 2003-06-20. The CMS Event Builder. https://arxiv.org/abs/physics/0306150

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Small but Tubby: A Magnetic Loop Antenna Made from 100 mm Copper Tubing

This paper presents the electrical model, key equations, and practical construction of a small transmitting magnetic loop antenna built from unusually large 100 mm diameter copper tubing. The large conductor surface area and wide-area transitions to the vacuum capacitors were designed to minimize resistive losses. The frequency range from 1.8 MHz to 31 MHz is unusually wide. Frequency, impedance matching, and azimuth are all adjusted automatically by servo motors. Indoor losses originate predominantly from near-field coupling to the environment rather than from the antenna itself. Temperature-rise measurements confirm that the bulk of the dissipated power is absorbed by the environment, not by the antenna components. The conducted H-field measurements demonstrate good agreement between the measured H-field and the theoretical free-space H-field calculated from the antenna geometry and an estimated loop current. The loop current was estimated from the measured antenna bandwidth and the applied transmit power. The antenna was developed for indoor operation where outdoor installation is not possible.

physics.ins-det↗

Triaxial $μ$-PIC for resolving Multi-Hit Ambiguity

The micro pixel chamber ($μ$-PIC), a type of micro-pattern gaseous detectors (MPGD), features pixel electrodes structured similarly to a sliced proportional counter. Conventionally, $μ$-PIC electrodes are connected to orthogonal strip electrodes to reduce the number of readout circuits; however, this configuration introduces multi-hit ambiguity when tracing winding tracks or during high-rate operations. A well-known solution to this problem is the adoption of an additional readout axis. To this end, we designed a new electrode structure using Garfield++ simulations and fabricated a triaxial $μ$-PIC based on through-glass-via (TGV) technology. This triaxial $μ$-PIC achieved a high gas gain of $1.1\times 10^4$ and the energy resolution of 22\% (FWHM) at 5.9~keV, Furthermore, the false-hit probability was less than 0.78\% at a 95\% confidence level for two clusters separated by a distance of over 3 mm, consistent with Garfield++ predictions. With this triaxial $μ$-PIC, single avalanche signals are collected from three independent readout strip electrodes (the anode and two cathodes). The charge ratio among these electrodes remains nearly constant at anode:U-cathode:V-cathode=3:2:1. In addition, we successfully achieved an enhanced gain of $3.2\times 10^4$ without increasing the discharge risk by employing an alternative operation mode.

physics.ins-det↗

Experimental Characterization of Bulk Micromegas for Development of Active Target Time Projection Chamber for Nuclear Astrophysics Studies

A Micromegas-based active target Time Projection Chamber, namely Saha Active Target TPC (SAT-TPC), is under development at Saha Institute of Nuclear Physics for its application in nuclear astrophysics experiment to measure the branching ratio of the direct and sequential decay of the Hoyle state of $^{12}$C. A bulk Micromegas was characterized to optimize its operating parameters and its performance for $α$-particle tracking was investigated using gas mixtures Ar + CO$_{2}$ (90:10) and Ar + i-C$_4$H$_{10}$ (95:5) at atmospheric pressure using 5.9~keV X-ray and 5.48~MeV $α$-particles from radioactive sources. A hydrodynamic transport model was used to simulate the charge-deposit profile of the $α$-particle track on the Micromegas readout and compared to the experimental data to complement the experimental measurement as well as validate the numerical model. A good agreement was observed that confirmed the suitability of the choice of the bulk Micromegas in the development of the SAT-TPC prototype and the hydrodynamic modelling of the detector dynamics

physics.ins-det↗