Measurement of the Blackbody Radiation Shift of the 133Cs Hyperfine Transition in an Atomic Fountain
Abstract
We used a Cs atomic fountain frequency standard to measure the Stark shift on the ground state hyperfine transiton frequency in cesium (9.2 GHz) due to the electric field generated by the blackbody radiation. The measures relative shift at 300 K is -1.43(11)e-14 and agrees with our theoretical evaluation -1.49(07)e-14. This value differs from the currently accepted one -1.69(04)e-14. The difference has a significant implication on the accuracy of frequency standards, in clocks comparison, and in a variety of high precision physics tests such as the time stability of fundamental constants.
Explore related subjects
Keep this discovery
F. Levi, D. Calonico, L. Lorini, S. Micalizio, A. Godone. 2003-10-13. Measurement of the Blackbody Radiation Shift of the 133Cs Hyperfine Transition in an Atomic Fountain. https://doi.org/10.1103/physreva.70.033412
Cite the original work for its findings. Save a collection to share your selection of sources.