Search arXivSearch

arXiv · physics/0402123

Off-diagonal impedance in amorphous wires and application to linear magnetic sensors

Abstract

The magnetic-field behaviour of the off-diagonal impedance in Co-based amorphous wires is investigated under the condition of sinusoidal (50 MHz) and pulsed (5 ns rising time) current excitations. For comparison, the field characteristics of the diagonal impedance are measured as well. In general, when an alternating current is applied to a magnetic wire the voltage signal is generated not only across the wire but also in the coil mounted on it. These voltages are related with the diagonal and off-diagonal impedances, respectively. It is demonstrated that these impedances have a different behaviour as a function of axial magnetic field: the former is symmetrical and the latter is antisymmetrical with a near linear portion within a certain field interval. In the case of the off-diagonal response, the dc bias current eliminating circular domains is necessary. The pulsed excitation that combines both high and low frequency harmonics produces the off-diagonal voltage response without additional bias current or field. This suits ideal for a practical sensor circuit design. The principles of operation of a linear magnetic sensor based on C-MOS transistor circuit are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. I. Sandacci, D. P. Makhnovskiy, L. V. Panina, K. Mohri, Y. Honkura. 2004-02-25. Off-diagonal impedance in amorphous wires and application to linear magnetic sensors. https://doi.org/10.1109/tmag.2004.835676

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det