Search arXiv⌕ Search

arXiv · physics/0606104

Status of a DEPFET pixel system for the ILC vertex detector

Abstract

We have developed a prototype system for the ILC vertex detector based on DEPFET pixels. The system operates a 128x64 matrix (with ~35x25 square micron large pixels) and uses two dedicated microchips, the SWITCHER II chip for matrix steering and the CURO II chip for readout. The system development has been driven by the final ILC requirements which above all demand a detector thinned to 50 micron and a row wise read out with line rates of 20MHz and more. The targeted noise performance for the DEPFET technology is in the range of ENC=100 e-. The functionality of the system has been demonstrated using different radioactive sources in an energy range from 6 to 40keV. In recent test beam experiments using 6GeV electrons, a signal-to-noise ratio of S/N~120 has been achieved with present sensors being 450 micron thick. For improved DEPFET systems using 50 micron thin sensors in future, a signal-to-noise of 40 is expected.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Trimpl, M. Koch, R. Kohrs, H. Krueger, P. Lodomez, L. Reuen, C. Sandow, E. v. Toerne, J. J. Velthuis, N. Wermes, L. Andricek, H. G. Moser, R. H. Richter, G. Lutz, F. Giesen, P. Fischer, I. Peric. 2006-12-07. Status of a DEPFET pixel system for the ILC vertex detector. https://doi.org/10.1016/j.nima.2005.11.204

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Small but Tubby: A Magnetic Loop Antenna Made from 100 mm Copper Tubing

This paper presents the electrical model, key equations, and practical construction of a small transmitting magnetic loop antenna built from unusually large 100 mm diameter copper tubing. The large conductor surface area and wide-area transitions to the vacuum capacitors were designed to minimize resistive losses. The frequency range from 1.8 MHz to 31 MHz is unusually wide. Frequency, impedance matching, and azimuth are all adjusted automatically by servo motors. Indoor losses originate predominantly from near-field coupling to the environment rather than from the antenna itself. Temperature-rise measurements confirm that the bulk of the dissipated power is absorbed by the environment, not by the antenna components. The conducted H-field measurements demonstrate good agreement between the measured H-field and the theoretical free-space H-field calculated from the antenna geometry and an estimated loop current. The loop current was estimated from the measured antenna bandwidth and the applied transmit power. The antenna was developed for indoor operation where outdoor installation is not possible.

physics.ins-det↗

Triaxial $μ$-PIC for resolving Multi-Hit Ambiguity

The micro pixel chamber ($μ$-PIC), a type of micro-pattern gaseous detectors (MPGD), features pixel electrodes structured similarly to a sliced proportional counter. Conventionally, $μ$-PIC electrodes are connected to orthogonal strip electrodes to reduce the number of readout circuits; however, this configuration introduces multi-hit ambiguity when tracing winding tracks or during high-rate operations. A well-known solution to this problem is the adoption of an additional readout axis. To this end, we designed a new electrode structure using Garfield++ simulations and fabricated a triaxial $μ$-PIC based on through-glass-via (TGV) technology. This triaxial $μ$-PIC achieved a high gas gain of $1.1\times 10^4$ and the energy resolution of 22\% (FWHM) at 5.9~keV, Furthermore, the false-hit probability was less than 0.78\% at a 95\% confidence level for two clusters separated by a distance of over 3 mm, consistent with Garfield++ predictions. With this triaxial $μ$-PIC, single avalanche signals are collected from three independent readout strip electrodes (the anode and two cathodes). The charge ratio among these electrodes remains nearly constant at anode:U-cathode:V-cathode=3:2:1. In addition, we successfully achieved an enhanced gain of $3.2\times 10^4$ without increasing the discharge risk by employing an alternative operation mode.

physics.ins-det↗

Experimental Characterization of Bulk Micromegas for Development of Active Target Time Projection Chamber for Nuclear Astrophysics Studies

A Micromegas-based active target Time Projection Chamber, namely Saha Active Target TPC (SAT-TPC), is under development at Saha Institute of Nuclear Physics for its application in nuclear astrophysics experiment to measure the branching ratio of the direct and sequential decay of the Hoyle state of $^{12}$C. A bulk Micromegas was characterized to optimize its operating parameters and its performance for $α$-particle tracking was investigated using gas mixtures Ar + CO$_{2}$ (90:10) and Ar + i-C$_4$H$_{10}$ (95:5) at atmospheric pressure using 5.9~keV X-ray and 5.48~MeV $α$-particles from radioactive sources. A hydrodynamic transport model was used to simulate the charge-deposit profile of the $α$-particle track on the Micromegas readout and compared to the experimental data to complement the experimental measurement as well as validate the numerical model. A good agreement was observed that confirmed the suitability of the choice of the bulk Micromegas in the development of the SAT-TPC prototype and the hydrodynamic modelling of the detector dynamics

physics.ins-det↗