Search arXivSearch

arXiv · physics/0610204

Evaluation of a lingual interface as a passive surgical guiding system

Abstract

Under conventional "open-" surgery, the physician has to take care of the patient, interact with other clinicians and check several monitoring devices. Nowadays, the Computer Assisted Surgery proposes to integrate 3D cameras in the operating theatre in order to assist the surgeon in performing minimal-invasive surgical punctures. The cameras localize the needle and the computer guides the surgeon towards an intracorporeal clinically-defined target. A visualization system (screen) is employed to provide the surgeon with indirect visual spatial information about the intracorporeal positions of the needle. The present work proposes to use another sensory modality to guide the surgeon thus keeping the visual modality fully dedicated to the surgical gesture. For this, the sensory substitution paradigm using the Bach-y-Rita's "Tongue Display Unit" (TDU) is exploited to provide to the surgeon information of the position tool. The TDU device is composed of a 6x6 matrix of electrodes transmitting electrotactile information on the tongue surface. The underlying idea consists in transmitting information about the deviation of the needle movement with regard to a pre-planned "optimal" trajectory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jose Vázquez-Buenosaires, Yohan Payan, Jacques Demongeot. 2006-10-24. Evaluation of a lingual interface as a passive surgical guiding system. https://arxiv.org/abs/physics/0610204

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph