Search arXiv⌕ Search

arXiv · physics/0702003

Waiting time analysis of foreign currency exchange rates: Beyond the renewal-reward theorem

Abstract

We evaluate the average waiting time between observing the price of financial markets and the next price change, especially in an on-line foreign exchange trading service for individual customers via the internet. Basic technical idea of our present work is dependent on the so-called renewal-reward theorem. Assuming that stochastic processes of the market price changes could be regarded as a renewal process, we use the theorem to calculate the average waiting time of the process. In the conventional derivation of the theorem, it is apparently hard to evaluate the higher order moments of the waiting time. To overcome this type of difficulties, we attempt to derive the waiting time distribution Omega(s) directly for arbitrary time interval distribution (first passage time distribution) of the stochastic process P_{W}(tau) and observation time distribution P_{O}(t) of customers. Our analysis enables us to evaluate not only the first moment (the average waiting time) but also any order of the higher moments of the waiting time. Moreover, in our formalism, it is possible to model the observation of the price on the internet by the customers in terms of the observation time distribution P_{O}(t). We apply our analysis to the stochastic process of the on-line foreign exchange rate for individual customers from the Sony bank and compare the moments with the empirical data analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Naoya Sazuka, Jun-ichi Inoue. 2007-02-01. Waiting time analysis of foreign currency exchange rates: Beyond the renewal-reward theorem. https://searcharxiv.org/abs/physics/0702003

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

A Paired Monte Carlo Intensity-Ratio Method for Incorporating Detector Resolution in Amplitude Analysis

Finite detector resolution can bias resonance parameters and fit fractions extracted from amplitude analyses. We present the paired Monte Carlo intensity-ratio method for incorporating resolution effects into amplitude analysis. The method uses ratios of reference intensities evaluated at paired truth-level and reconstructed kinematics to reweight the Monte Carlo normalization and approximately account for detector resolution. A resampling study of simulated $D^+\to K^+π^+π^-π^0$ decays shows that the method substantially reduces resolution-induced shifts in fitted resonance widths. Likelihood evaluation uses intensity calculations and normalization sums, avoiding a response convolution at each data event.

physics.data-an↗

Distinguishing thyroid nodule malignancy using digital palpation

Accurate pre-operative diagnosis of thyroid nodules remains a major clinical challenge. Current diagnostic techniques rely on fine-needle aspiration and demonstrate high rates of inconclusive results, often leading to avoidable thyroidectomies with lifelong implications. Here, we introduce a mechanics-based diagnostic method that leverages Digital Palpation to determine malignancy and identify tissue subtypes in human thyroid nodules. From a cohort of patients undergoing thyroidectomies, we evaluated ex vivo thyroid specimens and processed the resulting mechanical data from 36 tests in 10 thyroid nodules. Principal Component Analysis reveals that these experimental results are distributed within a three-dimensional space of interpretable scalar features reflecting tissue grittiness, strength, and toughness, which map closely to descriptions of malignant and benign nodules given by clinicians. Our results further demonstrate that malignant nodules exhibit distinct mechanical signatures compared to their benign counterparts. This revealed a statistically significant difference (p = 9 x 10^-4) and separability (95% lower-bound Hedges' g = 1.08) between benign and malignant nodules along a direction in principal component space representing effective stiffness. Preliminary clustering patterns were also observed among malignant subtypes, including follicular, oncocytic, and papillary thyroid carcinomas. Together, these results highlight the potential of Digital Palpation as a novel mechanics-based method for tissue characterization and motivate its further development toward diagnostic applications.

physics.data-an↗

Numerical Integration Instabilities in Likelihood Fits: Mechanisms and Remedies

Numerical instabilities in the normalization of probability density functions can produce artificially lower negative log-likelihood (NLL) values than the true minimum of a likelihood fit, even when the resulting fit provides a poorer description of the data. Motivated by anomalously low NLL values found in non-converged fits associated with a recent CMS search for fully charmed tetraquark candidates, we use a pseudo-dataset generated from a likelihood model based on that analysis to investigate how numerical integration can yield unreliable normalization results, how these errors affect likelihood minimization, and how they can be addressed. We find that, even at fixed integration tolerance, the stopping decision of a numerical integrator can change with the fit parameters, introducing discontinuities in the normalization integrals that propagate to the likelihood surface. Such discontinuities can trap the minimizer at a numerical step and yield an artificially lower NLL. Tightening the integration tolerance mitigates these numerical discontinuities, while adaptive integration methods, such as Gauss--Kronrod quadrature, can also improve the numerical stability. A more severe failure occurs when the integration grid cannot adequately resolve a sharply localized contribution. In this case, the integrator may satisfy its estimated-error criterion despite substantially underestimating the normalization, allowing the minimizer to enter a region with an artificially low NLL. Tightening integration tolerances or using alternative adaptive integration methods does not necessarily resolve sharply localized contributions. We demonstrate that a suitable variable transformation can improve their numerical resolution, yielding more accurate normalization integrals and restoring fit convergence.

physics.data-an↗