Energy calibration of the NaI(Tl) calorimeter of the SND detector using cosmic muons
Abstract
The general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 ÷1.4$ GeV. The energy calibration of the NaI(Tl) calorimeter of the SND detector with cosmic muons is described. Using this method, the energy resolution of $5.5 % (σ)$ for 500 MeV photons was achieved.