Search arXivSearch

arXiv subjects

A. Homna

Publications and source records attributed to A. Homna.

2 recordsLinked to original sources

Electronics design and testing of the CMS Fast Beam Condition Monitor for HL-LHC

The high-luminosity upgrade of the LHC (HL-LHC) brings unprecedented requirements for precision bunch-by-bunch luminosity measurement and beam-induced background monitoring in real time. A key component of the CMS Beam Radiation Instrumentation and Luminosity detector system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is able to operate independently at all times with a triggerless asynchronous readout. FBCM utilizes a dedicated front-end ASIC to amplify the signals from CO$_2$-cooled silicon-pad sensors with 1 ns timing resolution. Front-end (FE) electronics are subject to high-radiation conditions, thus all components are radiation hardened: sensors, ASICs, transceivers, etc. The FBCM ASIC contains 6 channels, each outputting a high-speed binary signal carrying the time-of-arrival and time-over-threshold information. This signal is sent via a gigabit optical link to the back-end electronics for analysis. A dedicated test system is designed for the FBCM FE electronics with a modular setup for all testing needs of the project from initial ASIC validation test to system-level testing with the full read-out chain. The paper reports on the design, read-out architecture, and testing program for the FBCM electronics.

physics.ins-det

The CMS Fast Beam Condition Monitor for HL-LHC

The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and data acquisition services and able to operate at all times with a triggerless readout. FBCM utilizes a dedicated front-end application-specific integrated circuit (ASIC) to amplify the signals from CO$_2$-cooled silicon-pad sensors with a timing resolution of a few nanoseconds, which enables the measurement of the beam-induced background. FBCM uses a modular design with two half-disks of twelve modules at each end of CMS, with four service modules placed close to the outer edge to reduce radiation-induced aging. The electronics system design adapts several components from the CMS Tracker for power, control and read-out functionalities. The dedicated FBCM23 ASIC contains six channels and adjustable shaping time to optimize the noise with regards to sensor leakage current. Each ASIC channel outputs a single binary high-speed asynchronous signal carrying time-of-arrival and time-over-threshold information. The chip output signal is digitized, encoded and sent via a radiation-hard gigabit transceiver and an optical link to the back-end electronics for analysis. This paper reports on the updated design of the FBCM detector and the ongoing testing program.

physics.ins-det