Search arXiv⌕ Search

arXiv subjects

Alessandro Ramalli

Publications and source records attributed to Alessandro Ramalli.

3 recordsLinked to original sources

WASP: Weakly Aligned Spatiotemporal Pairs for Fetal Brain MRI-Ultrasound Learning

Magnetic Resonance Imaging (MRI) is widely regarded as the optimal sensor for fetal brain analysis due to its superior soft-tissue contrast and anatomical detail. However, its high cost and operational burden make it invasive and difficult to obtain at scale. Ultrasound (US), in contrast, is cheap, safe, and routinely acquired, and as a result it has produced substantially larger datasets and a growing ecosystem of pretrained models. This asymmetry raises a natural question: Can we teach a US-only model to understand fetal MRI from only a limited set of examples? The standard recipe, training a foundation model on subject-to-subject paired MRI-US scans, is not viable since no such paired fetal dataset is publicly available. In this paper we address this gap with Weakly Aligned Spatiotemporal Pairs (WASP), a framework that formulates cross-modal correspondence as an entropic Optimal Transport problem driven by clinical metadata, in particular Gestational Age (GA) and diagnostic planes, enabling the fitting of a lightweight alignment module that lifts MRI representations into the US latent space, without fine-tuning the backbone. Empirically, WASP yields its largest gains when MRI is unseen by the model during pretraining (on USFM, GA estimation error drops from 21.9 to 17.4 days and standard plane classification accuracy climbs from 61.9% to 69.0%), while providing smaller, backbone-dependent refinements for backbones pretrained on both modalities (e.g., BioMedParse GA estimation error from 6.5 to 6.0 days and SAM-Med2d plane accuracy from 83.3% to 88.1%). Code is available at https://github.com/miccunifi/WASP.

cs.CV↗

3-D Coherent Multi-Transducer Ultrasound Imaging with Sparse Spiral Arrays

Coherent multi-transducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. The subwavelength localization accuracy of the multiple transducers required to coherently beamform the data is achieved by using the echoes backscattered from targeted points. In this study, CoMTUS is implemented and demonstrated for the first time in 3-D imaging using a pair of 256-element 2-D sparse spiral arrays, which keep the channel-count low and limit the amount of data to be processed. The imaging performance of the method was investigated using both simulations and phantom tests. The feasibility of free-hand operation is also experimentally demonstrated. Results show that, in comparison to a single dense array system using the same total number of active elements, the proposed CoMTUS system improves spatial resolution (up to 10 times) in the direction where both arrays are aligned, contrast-to-noise-ratio (CNR, up to 30%), and generalized CNR (up to 11%). Overall, CoMTUS shows narrower main lobe and higher contrast-to-noise-ratio, which results in an increased dynamic range and better target detectability.

physics.med-ph↗

Impact of aperture, depth, and acoustic clutter on performance of Coherent Multi-Transducer Ultrasound imaging

Transducers with larger aperture size are desirable in ultrasound imaging to improve resolution and image quality. A coherent multi-transducer ultrasound imaging system (CoMTUS) enables an extended effective aperture through coherent combination of multiple transducers. In this study, the discontinuous extended aperture created by CoMTUS and its performance for deep imaging and through layered-media are investigated by both simulations and experiments. Typical image quality metrics - resolution, contrast and contrast-to-noise ratio - are evaluated and compared with a standard single probe imaging system. Results suggest that, the image performance of CoMTUS depends on the relative spatial location of the arrays. The resulting effective aperture significantly improves resolution, while the separation between the arrays may degrade contrast. For a limited gap in the effective aperture (less than few centimetres), CoMTUS provides benefits to image quality compared to standard single probe imaging system. Overall, CoMTUS shows higher sensitivity and reduced loss of resolution with imaging depth. In general, CoMTUS imaging performance was unaffected when imaging through a layered-medium with different speed of sound values and resolution improved up to 80% at large imaging depths.

physics.med-ph↗