Search arXiv⌕ Search

arXiv subjects

Andrii Natochii

Publications and source records attributed to Andrii Natochii.

3 recordsLinked to original sources

Design of the Electron-Beam Collimator for the Electron-Ion Collider

The design and optimization of a beam collimator for the Electron Storage Ring (ESR) of the Electron-Ion Collider (EIC) are presented. The collimator must efficiently intercept stray beam particles while maintaining acceptable beam coupling impedance, surviving rapid accidental beam impacts, and withstanding steady-state beam-induced heating. An integrated design approach combining beam-loss tracking, electromagnetic-shower simulations, thermomechanical analysis, and impedance calculations is developed and benchmarked against published simulations and beam-impact experiments. A comparison of candidate absorber materials identifies Al2219-T62 as providing a favorable balance of beam-impact robustness, thermal and electrical conductivity, mechanical strength, and ultra-high-vacuum compatibility. For the ultimate ESR bunch charge of 28 nC at 10 GeV, the Al2219-T62 jaw remains below the adopted practical thermal-shock threshold for approximately 50 fully intercepted bunches and below the localized melting threshold for approximately 100 bunches under the reference impact conditions considered. These results provide an engineering input to the machine-protection requirements, for which a complete protection response within several machine turns is required. Optimization of the absorber-tip length yields a 70 mm tapered jaw that balances collimation performance, beam-impact robustness, and impedance. The resulting design maintains acceptable impedance margins and remains below both the yield and ultimate tensile strengths under a conservative 3.6 kW beam-induced heating scenario. The results establish a baseline ESR collimator design and a benchmarked methodology for evaluating collimator robustness in high-current electron storage rings.

physics.acc-ph↗

A Collimation System Baseline Design for the Electron Storage Ring at the Electron-Ion Collider

We present the baseline design of the electron ring collimation system for the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL). The system addresses beam losses in a high-current electron storage ring with superconducting (SC) final-focus magnets and sensitive detectors, where uncontrolled losses can generate heat loads, radiation, and detector backgrounds and damage. The proposed collimation insertion localizes halo particle losses through reducing interaction region beam losses from beam-gas and Touschek scattering by several orders of magnitude while keeping detector backgrounds and cryostat heat loads within acceptable limits. Multi-turn particle tracking simulations show that the collimators do not significantly impact machine acceptance or beam lifetime, and their positions and apertures can be re-optimized for future lattice configurations. Ongoing work includes incorporating crab cavities and solenoid fields into simulations, refining vacuum conditions, and optimizing collimator geometry and materials. This design establishes a robust baseline for the EIC electron ring collimation system and supports continued lattice optimization for machine operations.

physics.acc-ph↗

SynradG4: A Geant4-Based Extension for Synchrotron Radiation Background Studies in the ePIC Detector at the Electron-Ion Collider

The Electron-Ion Collider (EIC) will operate at high luminosity with multi-GeV, high-current electron beams, resulting in substantial synchrotron radiation (SR) emission in the electron storage ring (ESR). A detailed understanding of SR photon transport in the complex three-dimensional interaction region (IR) geometry is critical for estimating backgrounds in the ePIC detector and for developing effective shielding and masking strategies. This paper presents SynradG4, an EIC-specific extension of Geant4 designed for fast photon tracking in vacuum using established SR reflection and rough surface scattering models. SynradG4 integrates the photon reflection models of Synrad+ within the Geant4 geometry and field framework, while disabling all bulk matter interactions to achieve high-statistics transport through the 50-m-long IR vacuum system. Absorbed photon coordinates are then passed to a second-stage DD4hep simulation, where full electromagnetic processes such as photoabsorption, Compton scattering, Rayleigh scattering, and fluorescence are enabled for propagation through the beam pipe and detector materials. SynradG4 is not intended to replace general SR simulation codes; rather, it complements them by providing the workflow and geometry integration capabilities needed for EIC-specific background studies. Benchmark tests against Synrad+, Synrad3D, and the native Geant4 X-ray reflection model demonstrate excellent agreement for specular and diffuse reflection regimes. Using the full IR geometry and machine lattice, we present the first SR background estimates for the ePIC detector and evaluate the impact of potential SR masks.