Search arXiv⌕ Search

arXiv subjects

Arnaud Dubory

Publications and source records attributed to Arnaud Dubory.

5 recordsLinked to original sources

Impact-Based Analysis Method (IBAM) to evaluate the primary stability of the pedicle screw: A proof of concept

The long-term success of spinal instrumentation depends on the initial stability of pedicle screws (PS), yet current intraoperative assessments rely on surgeon subjectivity. This study introduces a quantitative, non-invasive approach-the Impact-Based Analysis Method (IBAM)-to support intraoperative decision-making. The IBAM measures screw stability using low-amplitude impacts delivered with an instrumented hammer on the surgical screwdriver after screw insertion. An IBAM indicator, defined as the average time difference between the two earliest local maxima in the force signal, was analyzed under varying stability conditions in artificial bone samples. Experimental factors included bone density ($ρ$), insertion depth ( D ), and pilot hole diameter ( $Φ$ ). The IBAM indicator was compared with the PS pull-out force for each configuration. Although the main effects showed opposite trends for the pull-out force and the IBAM indicator, their relative magnitudes were similar ( $ρ$ $\sim$35%, D $\sim$25%, $Φ$ $\sim$15%). The relationship between the pull-out force and the IBAM indicator followed a power-law model (adjusted R 2 =___0.85) with a negative exponent. As screw stability increased, the pull-out force rose while the IBAM indicator decreased, demonstrating complementary sensitivity to bone-implant interface changes. While results are promising, the simplified experimental design limited the ability to fully capture bone-implant interaction complexity. Future studies should aim to validate IBAM in vivo to confirm its clinical applicability..

physics.med-ph↗

Using an instrumented hammer to predict the lateral hinge fracture in high tibial osteotomy: A cadaveric study

Open-wedge High-Tibial Osteotomy is the most commonly employed technique addressing varus knee osteoarthritis. During this procedure, the osteotome passes through cortical and trabecular bone. A common complication is lateral hinge fractures, which depends upon when the surgeon stops impacting the osteotome. The aim of the present study is to determine whether an instrumented hammer can be employed to detect (i) the bone type (cortical or trabecular) surrounding the osteotome tip and (ii) when bone is fractured by the osteotome. Seventeen lower-limb specimens were obtained from nine fresh human anatomical subjects. The osteotome was impacted using the instrumented hammer until rupture. Each impact signal was recorded and analyzed. An algorithm was developed to detect the transitions between cortical and trabecular bone and vice versa. Detection was based on the relative variation of $τ$ derived from the force signal as a function of time as the time difference between the second___and___first impact peaks. The values of $τ$ were significantly lower in cortical bone compared to trabecular bone. Considering the arrival of the osteotome tip in trabecular bone during a medial, a difference of less than 2 impacts between the surgeon and the algorithm was obtained for 71% of the cases. For the lateral osteotomy it was obtained in 81% of the cases. This cadaveric study demonstrated that the instrumented hammer could prevent impacts leading to hinge rupture, which suggests that future clinical trials are warranted.

physics.med-ph↗

An Instrumented Hammer to Detect the Bone Transitions During an High Tibial Osteotomy: An Animal Study

High tibial osteotomy is a common procedure for knee osteoarthritis during which the surgeon partially opens the tibia and must stop impacting when cortical bone is reached by the osteotome. Surgeons rely on their proprioception and fluoroscopy to conduct the surgery. Our group has developed an instrumented hammer to assess the mechanical properties of the material surrounding the osteotome tip. The aim of this ex vivo study is to determine whether this hammer can be used to detect the transition from cortical to trabecular bone and vice versa. Osteotomies were performed until rupture in pig tibia using the instrumented hammer. An algorithm was developed to detect both transitions based on the relative variation of an indicator derived from the time variation of the force. The detection by the algorithm of both transitions was compared with the position of the osteotome measured with a video camera and with surgeon proprioception. The difference between the detection of the video and the algorithm (respectively, the video and the surgeon; the surgeon and the algorithm) is 1.0$\pm$1.5 impacts (respectively, 0.5$\pm$0.6 impacts; 1.4$\pm$1.8 impacts), for the detection of the transition from the cortical to trabecular bone. For the transition from the trabecular to cortical bone, the difference is 3.6$\pm$2.6 impacts (respectively, 3.9$\pm$2.4 impacts; 0.8$\pm$0.9 impacts), and the detection by the algorithm was always done before the sample rupture. This ex vivo study demonstrates that this method could prevent impacts leading to hinge rupture.

physics.med-ph↗

Using an instrumented hammer during Summers osteotomy: an animal model

Summers osteotomy is a technique used to increase bone height and to improve bone density in dental implant surgery. The two main risks of this surgery, which is done by impacting an osteotome in bone tissue, are i) to perforate the sinus membrane and ii) the occurrence of benign paroxysmal vertigo, which are both related to excessive impacts during the osteotomy. Therefore, impacts must be carefully modulated. The aim of this study is to determine whether an instrumented hammer can predict bone damage before the total osteotome protrusion. 35 osteotomies were performed in 9 lamb palate samples using a hammer instrumented with a force sensor to record the variation of the force as a function of time s(t). A signal processing was developed to determine the parameter $τ$ corresponding to the time between the first two peaks of s(t). A camera was used to determine the impact number for damage: NVideo. The surgeon determined when damage occurred, leading to NSurg. An algorithm was developed to detect bone damage based on the variation of $τ$ as a function of the impact number, leading to Ncrit. The algorithm was always able to detect bone damage before total protrusion of the osteotome. We obtained NVideo -NCrit > -2 (respectively NSurg -NCrit > -2) for 97 % (respectively 94 %) of the cases, which indicates the algorithm was almost always able to detect bone damage at most one impact after the video (respectively the surgeon). Our results pave the way to safer Summers osteotomy.

physics.med-ph↗

Ex vivo estimation of cementless femoral stem stability using an instrumented hammer

Background 15 The success of cementless hip arthroplasty depends on the primary stability of the femoral stem. It remains difficult to assess the optimal number of impacts to guarantee the femoral stem stability while avoiding bone fracture. The aim of this study is to validate a method using a hammer instrumented with a force sensor to monitor the insertion of femoral stem in bovine femoral samples. Methods 20 Different cementless femoral stem were impacted into five bovine femur samples, leading to 99 configurations. Three methods were used to quantify the insertion endpoint: the impact hammer, video motion tracking and the surgeon proprioception. For each configuration, the number of impacts performed by the surgeon until he felt a correct insertion was noted Nsurg. The insertion depth E was measured through video motion tracking, and the impact number Nvid corresponding to the end of the insertion was estimated. Two indicators, noted I and D, 25 were determined from the analysis of the time variation of the force, and the impact number Nd corresponding to a threshold reached in D variation was estimated. Findings The pullout force of the femoral stem was significantly correlated with I (R${}^2$=0.81). The values of Nsurg, Nvid and Nd were similar for all configurations. 30 Interpretation The results validate the use of the impact hammer to assess the primary stability of the femoral stem and the moment when the surgeon should stop the impaction procedure for an optimal insertion, which could lead to the development of a decision support system. Abstract: 248 words. Main text: 4658 words

physics.med-ph↗