Search arXiv⌕ Search

arXiv subjects

Atri Bera

Publications and source records attributed to Atri Bera.

3 recordsLinked to original sources

Reliability-based Sizing of Energy Storage for Large Load Integration

The number of large loads connected to the bulk power system has been increasing rapidly worldwide. Emerging high-demand facilities, particularly AI data centers, are introducing new challenges for power system planners. In absence of appropriate planning mechanisms, the addition of high volumes of data center loads will lead to an increase in outages, thus degrading reliability of the system. Energy storage systems (ESS) offer a promising solution to mitigate the reliability impacts of these large loads, due to their flexibility and fast-ramping characteristics. However, ESS should be judiciously sized and sited to maximize the reliability benefits to the grid. This paper presents a framework for the optimal sizing and siting of ESS to minimize the adverse reliability impacts of large load additions. First, a stochastic semi-Markov model is developed to model the load of AI data centers and generate profiles for several such facilities. These profiles are then incorporated into a Markov-chain Monte Carlo simulation-based composite system reliability assessment framework. A detailed nodal network model is used to quantify the reliability impacts of adding data centers and to identify buses most affected by large loads. Resource adequacy metrics are used to evaluate the overall system reliability impacts. ESS are then strategically sized and sited based on this analysis to mitigate the negative impacts of large loads on overall system reliability. The proposed framework is demonstrated using the RTS-GMLC 72-bus test system. The results show how ESS can effectively enhance system reliability in the presence of rapidly growing large-load demand. This framework provides system planners, utilities, and regulators with a practical tool for maintaining reliable power system operation using energy storage as more large loads are integrated into the grid.

eess.SY↗

A Hierarchical Semi-Markov Load Model for AI Data Centers Coupling Job Scheduling with Bulk-Synchronous-Parallel Power Dynamics

AI data centers are emerging as a dominant new load class with their power dynamics fundamentally from conventional industrial loads. Inside a training job, the bulk-synchronous-parallel algorithm moves each node through compute, sync, and checkpoint steps, which swings power between full load and near idle within seconds. Across the whole facility, jobs arrive, take blocks of nodes for hours to days, then leave, so the number of busy nodes changes daily, weekly, and yearly. This slower shift drives facility-wide swings and the peak demand that sets the size of the grid link. A model that looks only at within-job behavior, and treats the facility as a fixed set of busy nodes, smooths out these swings and misses the true peak-to-average ratio. This paper develops a hierarchical semi-Markov Data-Center (HSM-DC) load model that couples two layers across two timescales. A job-scheduling layer creates jobs through a non-homogeneous compound-Poisson process shaped by daily, weekly, and seasonal patterns, gives each job a heavy-tailed node count and length, and places jobs on a fixed pool of nodes on a first-come basis. A within-job layer moves each busy node through a five-state semi-Markov chain for the BSP steps, with state-based Ornstein-Uhlenbeck noise. Facility power comes from this changing node count and the per-node power, set to match measured node data and the facility's straight-line power-versus-load curve. Configured to the reference facility at the same scale, the model matches mean power, its spread, and the peak-to-average ratio across load levels, with fit scores of 0.9997, 0.92, and 0.82. It also matches the share of queued jobs to within one point at high load. Facility-wide swings and peak demand come from how jobs arrive and get scheduled, so grid planning must model that process, not just scale up a single node's power curve.

eess.SY↗

Modal Analysis of Spatial Load Correlation in AI Data Center-Dominated Power Systems

Hyperscale AI data centers induce spatially and temporally correlated load fluctuations that violate classical independence assumptions and are not captured by time-averaged spectral methods. These correlations are episodic and non-stationary, so they demand analysis that resolves transient structure. This paper applies Dynamic Mode Decomposition (DMD) to the temporal evolution of pairwise inter-bus correlation coefficients and forms a low-dimensional state representation that enables modal analysis without a stationarity assumption. The recovered modes distinguish sustained coherence, decaying transients, and intensifying events, and their oscillation timescales map to underlying physical coupling mechanisms. The method is evaluated on an IEEE 39-bus Real-Time Digital Simulator (RTDS) testbed with three converter-interfaced AI data center loads driven by synthetic workload profiles. A global analysis attributes the dominant correlation energy to a slow thermal band, and a sliding-window analysis identifies brief intensification events in a small fraction of windows that align with stochastic workload coincidences. Cross-validation with RTDS voltage coherence confirms elevated coupling during these intervals. The proposed modal growth indicator provides an early-warning signal of correlation intensification, with a lead of of about 4~s before pairwise coherence reaches its peak.

eess.SY↗