Search arXivSearch

arXiv subjects

B. Plaster

Publications and source records attributed to B. Plaster.

At least 19 recordsLinked to original sources

Fundamental Nuclear and Particle Physics At Neutron Sources

Fundamental neutron and neutrino physics at neutron sources, combining precision measurements and theory, can probe new physics at energy scales well beyond the highest energies probed by the LHC and possible future high energy collider facilities. The European Spallation Source (ESS) will in the not too far future be a most powerful pulsed neutron source and simultaneously the world's brightest pulsed neutrino source. The ESS, and neutron sources in general, can provide unprecedented and unique opportunities to contribute to the search for the missing elements in the Standard Model of particle physics. Currently there are no strong indications where hints of the origin of the new physics will emerge. A multi-pronged approach will provide the fastest path to fill the gaps in our knowledge and neutron sources have a pivotal role to play. To survey the ongoing and proposed physics experiments at neutron sources and assess their potential impact, a workshop was held at Lund University in January, 2025. This report is a summary of that workshop and has been prepared as input to the European Strategy Update.

nucl-ex

Fundamental Neutron Physics: a White Paper on Progress and Prospects in the US

Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadronic parity violation. World-leading results from the US Fundamental Neutron Physics community since the last Long Range Plan, include the world's most precise measurement of the neutron lifetime from UCN$\tau$, the final results on the beta-asymmetry from UCNA and new results on hadronic parity violation from the NPDGamma and n-${^3}$He runs at the FNPB (Fundamental Neutron Physics Beamline), precision measurement of the radiative neutron decay mode and n-${}^4$He at NIST. US leadership and discovery potential are ensured by the development of new high-impact experiments including BL3, Nab, LANL nEDM and nEDM@SNS. On the theory side, the last few years have seen results for the neutron EDM from the QCD $\theta$ term, a factor of two reduction in the uncertainty for inner radiative corrections in beta-decay which impacts CKM unitarity, and progress on {\it ab initio} calculations of nuclear structure for medium-mass and heavy nuclei which can eventually improve the connection between nuclear and nucleon EDMs. In order to maintain this exciting program and capitalize on past investments while also pursuing new ideas and building US leadership in new areas, the Fundamental Neutron Physics community has identified a number of priorities and opportunities for our sub-field covering the time-frame of the last Long Range Plan (LRP) under development. This white paper elaborates on these priorities.

nucl-ex

Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $\beta$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $\beta$-decay electrons are detected with $\approx 4\pi$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $\beta$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.

nucl-ex

A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.

physics.ins-det

Final results for the neutron $\beta$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $\beta$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

nucl-ex

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

nucl-ex

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $\alpha$, $^7$Li and $\gamma$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

physics.ins-det

Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow \chi + e^+e^-$

It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($\chi$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $\chi$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4\pi$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $\chi$ mass, on the branching fraction for this decay channel. For $\chi$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5\sigma$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $\chi+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.

nucl-ex

Search for the Neutron Decay n$\rightarrow$ X+$\gamma$ where X is a dark matter particle

In a recent paper submitted to Physical Review Letters, Fornal and Grinstein have suggested that the discrepancy between two different methods of neutron lifetime measurements, the beam and bottle methods can be explained by a previously unobserved dark matter decay mode, n$\rightarrow$ X+$\gamma$ where X is a dark matter particle. We have performed a search for this decay mode over the allowed range of energies of the monoenergetic gamma ray for X to be a dark matter particle. We exclude the possibility of a sufficiently strong branch to explain the lifetime discrepancy with greater than 4 sigma confidence.

nucl-ex

New result for the neutron $\beta$-asymmetry parameter $A_0$ from UCNA

The neutron $\beta$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $\lambda=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation coefficient using ultracold neutrons (UCN). Following improvements to the systematic uncertainties and increased statistics, we report the new result $A_0 = -0.12054(44)_{\mathrm{stat}}(68)_{\mathrm{syst}}$ which yields $\lambda\equiv \frac{g_{A}}{g_{V}}=-1.2783(22)$. Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces $A_0=-0.12015(34)_{\mathrm{stat}}(63)_{\mathrm{syst}}$ and $\lambda\equiv \frac{g_{A}}{g_{V}}=-1.2772(20)$.

nucl-ex

First direct constraints on Fierz interference in free neutron $\beta$ decay

Precision measurements of free neutron $\beta$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.

nucl-ex

Cryogenic magnetic coil and superconducting magnetic shield for neutron electric dipole moment searches

A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment (nEDM) search, which will take place at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory using ultra-cold neutrons (UCN). That search requires a uniform magnetic field to mitigate systematic effects and obtain long polarization lifetimes for neutron spin precession measurements. This paper details upgrades to a previously described apparatus, particularly the introduction of super-conducting magnetic shielding and the associated cryogenic apparatus. The magnetic gradients observed are sufficiently low for the nEDM search at SNS.

physics.ins-det

Frequency Shifts Induced by Field Gradients in Muon $g-2$ Experiments

Two prominent efforts aimed at probing beyond Standard Model physics, searches for a neutron electric dipole moment (EDM) and measurements of the muon $g-2$ anomalous magnetic moment, employ spin precession techniques. In the most recent neutron EDM experiment, frequency shifts induced by magnetic field gradients and $\mathbf{E} \times \mathbf{v}$ motional fields were a significant source of systematic error. We consider the possibility of a similar effect in the most recent muon $g-2$ experiment, and find that such an effect could potentially be as large as $\sim 1$ ppm fractional error, to be compared with the reported $\sim 0.5$ ppm error.

nucl-ex

Detection System for Neutron $\beta$ Decay Correlations in the UCNB and Nab experiments

We describe a detection system designed for precise measurements of angular correlations in neutron $\beta$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $\beta$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $\beta$ particles and recoil protons from neutron $\beta$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $\beta$ decay parameters $B$, $a$, and $b$.

physics.ins-det

Accessing interior magnetic field vector components in neutron electric dipole moment experiments via exterior measurements, I. Boundary-value techniques

We propose a new concept for determining the interior magnetic field vector components in neutron electric dipole moment experiments. If a closed three-dimensional boundary surface surrounding the fiducial volume of an experiment can be defined such that its interior encloses no currents or sources of magnetization, each of the interior vector field components and the magnetic scalar potential will satisfy a Laplace equation. Therefore, if either the vector field components or the normal derivative of the scalar potential can be measured on the surface of this boundary, thus defining a Dirichlet or Neumann boundary-value problem, respectively, the interior vector field components or the scalar potential (and, thus, the field components via the gradient of the potential) can be uniquely determined via solution of the Laplace equation. We discuss the applicability of this technique to the determination of the interior magnetic field components during the operating phase of neutron electric dipole moment experiments when it is not, in general, feasible to perform direct in situ measurements of the interior field components. We also study the specifications that a vector field probe must satisfy in order to determine the interior vector field components to a certain precision. The technique we propose here may also be applicable to experiments requiring monitoring of the vector magnetic field components within some closed boundary surface, such as searches for neutron-antineutron oscillations along a flight path or measurements in storage rings of the muon anomalous magnetic moment $g-2$ and the proton electric dipole moment.

nucl-ex

Comparison of magnetic field uniformities for discretized and finite-sized standard $\cos\theta$, solenoidal, and spherical coils

A significant challenge for experiments requiring a highly uniform magnetic field concerns the identification and design of a discretized and finite-sized magnetic field coil of minimal size. In this work we compare calculations of the magnetic field uniformities and field gradients for three different standard (i.e., non-optimized) types of coils: $\cos\theta$, solenoidal, and spherical coils. For an experiment with a particular requirement on either the field uniformity or the field gradient, we show that the volume required by a spherical coil form which satisfies these requirements can be significantly less than the volumes required by $\cos\theta$ and solenoidal coil forms.

physics.ins-det

Overlap Technique for End-Cap Seals on Cylindrical Magnetic Shields

We present results from studies of the effectiveness of an overlap technique for forming a magnetic seal across a gap at the boundary between a cylindrical magnetic shield and an end-cap. In this technique a thin foil of magnetic material overlaps the two surfaces, thereby spanning the gap across the cylinder and the end-cap, with the magnetic seal then formed by clamping the thin magnetic foil to the surfaces of the cylindrical shield and the end-cap on both sides of the gap. In studies with a prototype 31-cm diameter, 91-cm long, 0.16-cm thick cylindrical magnetic shield and flared end-cap, the magnetic shielding performance of our overlap technique is comparable to that obtained with the conventional method in which the end-cap is placed in direct lapped contact with the cylindrical shield via through bolts or screws.

physics.ins-det