AION-10: Technical Design Report for a 10m Atom Interferometer in Oxford

This Technical Design Report presents AION-10, a 10-meter atom interferometer to be located at Oxford University using ultracold strontium atoms to make precision measurements of fundamental physics. AION-10 serves as both a prototype for future larger-scale experiments and a versatile scientific instrument capable of conducting its own diverse physics programme. The design features a 10-meter vertical tower housing two atom interferometer sources in an ultra-high vacuum environment. Key engineering challenges include achieving nanometer-level vibrational stability and precise magnetic field control. Solutions include active vibration isolation, specialized magnetic shielding, and a modular assembly approach using professional lifting equipment. Detailed analysis confirms the design meets all performance requirements, with critical optical components remaining within our specifications 97% of the time under realistic operating conditions. Vacuum and vibration measurements in the host building validate that the instrument will achieve the precision needed for quantum sensing applications. This work establishes the technical foundation for scaling atom interferometry to longer baselines while creating a cutting-edge facility for precision measurements that could advance our understanding of fundamental physics.

physics.atom-ph

A prototype differential atom interferometer for fundamental physics

Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for Very Long-Baseline Atom Interferometers (VLBAIs) such as AION, MAGIS, AICE and AEDGE that aim to detect frequencies at which ground-based and space-borne laser interferometers lose sensitivity. VLBAIs look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. Experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr, realising for the first time a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the Standard Quantum Limit with no excess noise beyond atom shot noise, and the differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, emulating the conditions expected in a VLBAI. We further demonstrate recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomised conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying VLBAIs and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter.

hep-ex

Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories

This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.

physics.atom-ph

Bespoke magnetic field design for a magnetically shielded cold atom interferometer

Quantum sensors based on cold atoms are being developed which produce measurements of unprecedented accuracy. Due to shifts in atomic energy levels, quantum sensors often have stringent requirements on their internal magnetic field environment. Typically, background magnetic fields are attenuated using high permeability magnetic shielding, with the cancelling of residual and introduction of quantisation fields implemented with coils inside the shield. The high permeability shield, however, distorts all magnetic fields, including those generated inside the sensor. Here, we demonstrate a solution by designing multiple coils overlaid on a 3D-printed former to generate three uniform and three constant linear gradient magnetic fields inside the capped cylindrical magnetic shield of a cold atom interferometer. The fields are characterised in-situ and match their desired forms to high accuracy. For example, the uniform transverse field, $B_x$, deviates by less than $0.2$% over more than $40$% of the length of the shield. We also map the field directly using the cold atoms and investigate the potential of the coil system to reduce bias from the quadratic Zeeman effect. This coil design technology enables targeted field compensation over large spatial volumes and has the potential to reduce systematic shifts and noise in numerous cold atom systems.

physics.app-ph