Proof-of-concept of a xenon-based cryogenic heat pump demonstrator for future liquid xenon observatories

This manuscript details the proof-of-concept of a small-scale cryogenic heat pump demonstrator, a technology designed to enable high-flow xenon distillation systems for the removal of $^{222}$Rn in future liquid xenon observatories such as the XLZD experiment. The heat pump demonstrator operates on a left-turning Clausius-Rankine cycle, utilizing xenon as a phase-changing working medium. The design aims to fully hermetically separate the heat pump from the radon removal system, simplifying material cleanliness and maintenance compared to currently operating systems. Two demonstration tests were conducted at nominal pressures of $3.3\,\mathrm{bar}$ and $4.3\,\mathrm{bar}$, utilizing a cold head and electrical heaters to mimic the behavior of a xenon distillation system. In both measurements, the demonstrator achieved a cooling and heating power of $(118\pm3)\,\mathrm{W}$ and $(121\pm3)\,\mathrm{W}$, respectively. This is sufficient to operate a small distillation system with a virtual purification mass flow of about $3.1\,\mathrm{kg/h}$, while consuming $386\pm1\,\mathrm{W}$ electrical power. Compered to currently operating applications using commercial cold heads driven by helium compressors, which typically require about $6\,\mathrm{kW}$ of electrical power, this is significantly lower. The presented proof-of-concept heat pump demonstrator is further put into perspective with the currently planned XLZD experiment using a simplified scaling model. This model indicates that a radon removal system with a purification mass flow of $1600\,\mathrm{kg/h}$ and a required cooling and heating power of about $60\,\mathrm{kW}$ each, will be sufficient to cover a variety of different detector masses and background conditions.

physics.ins-det

The XENONnT Dark Matter Experiment

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.

physics.ins-det

Electro-purification studies and first measurement of relative permittivity of TMBi

A new type of detector for positron-emission tomography (PET) has been proposed recently, using a heavy organo-metallic liquid - TriMethyl Bismuth (TMBi) - as target material. TMBi is a transparent liquid with the high Z element Bismuth contributing 82% of its mass. 511keV annihilation photons are converted efficiently into photo-electrons within the detector material producing both Cherenkov light and free charge carriers in the liquid. While the optical component enables a fast timing, a charge readout using a segmented anode can provide an accurate position reconstruction and energy determination. The charge measurement requires a high level of purification, as any electronegative contaminants cause signal degradation. In addition to the purity requirements, the reactive nature of TMBi poses many challenges that need to be met until a fully functioning detector for PET applications can be realized. The paper presents an experimental setup that aims to remove electronegative impurities by electrostatic filtering and to characterise the properties of TMBi, e.g. the relative permittivity, for its application as a detector medium for charge read out.

physics.ins-det

Design, construction and commissioning of a high-flow radon removal system for XENONnT

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT liquid xenon inventory of 8.4 tonnes at process flows up to 71 kg/h (200 slpm) is required to achieve a radon reduction by a factor two for radon sources inside the detector. To reach such high flows, the distillation column's design features liquid xenon inlet and outlets along with novel custom-made bath-type heat exchangers with high liquefaction capabilities. The distillation process was designed using a modification of the McCabe-Thiele approach without a bottom product extraction. The thermodynamic concept is based on a Clausius-Rankine cooling cycle with phase-changing medium, in this case the xenon itself. To drastically reduce the external cooling power requirements, an energy efficient heat pump concept was developed applying a custom-made four cylinder magnetically-coupled piston pump as compressor. The distillation system was operated at thermodynamically stable conditions at a process flow of (91$\pm$2) kg/h ((258$\pm$6) slpm), 30 % over design. With this flow, a $^{222}$Rn activity concentration <1 $\mu$Bq/kg is expected inside the XENONnT detector given the measured radon source distribution.

physics.ins-det

Cryogenic bath-type heat exchangers for ultra-pure noble gas applications

Two cryogenic bath-type heat exchangers for ultra-pure noble gas applications were developed with particular emphasis on noble gas liquefaction in cryogenic distillation systems. The main objective was to construct heat exchangers for xenon from materials that do not emanate radon and that fulfill ultra-high vacuum standards. Therefore, only high-quality copper and stainless steel materials were used. Especially, large-area oxygen-free copper fins with high conductivity in a new design ensure efficient heat transfer. One bath-type Xe-Xe heat exchanger was designed with a diameter of 50 cm to achieve a xenon condensing capacity of at least 100 kg/h. In order to guarantee the necessary heat transfer between the two xenon reservoirs, this heat exchanger features a specially manufactured stainless steel flange with a copper plate welded inside. We first tested our concept on a dedicated bath-type heat exchanger with a reduced diameter of 30 cm using liquid nitrogen to liquefy the xenon. A model based on conservative assumptions such as film boiling on the nitrogen side and film condensation on the xenon side was developed and applied to caluclate the expected heat transfer for our design. We were able to demonstrate an adjustable xenon liquefaction rate of up to 113 kg/h limited only by our measurement procedure at a cooling efficiency of $(0.98\pm 0.03)$ for the LN$_2$-Xe heat exchanger.

physics.ins-det

Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.

physics.ins-det

Ultra-clean radon-free four cylinder magnetically-coupled piston pump

A high performance gas displacement pump based on four individual cylinders was developed. The magnetically-coupled pistons and the hermetically-sealed housings as well as the special cleanliness in terms of out-gassing and radio-purity make the four cylinder pump interesting for the usage in low background experiments dealing with noble gases as target. An optimized inner flow path as well as reduced dead volume with respect to the prototype single cylinder pump of the XENON1T experiment combined with advanced polymer piston gaskets and a piston coupling force of (3177 $\pm$ 162) N ensures a high and reliable performance. Furthermore, a phase-shifted synchronization of the pistons' movement creates an additional performance boost as well as minimizes fluctuations of flow and compression. The pump is able to generate xenon flows of 474 slpm at a pressure difference of 1.80 bar.

physics.ins-det

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of M\"unster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45{\deg} angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20{\deg} for the four samples and increases to up to 65% at 70{\deg} for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

physics.ins-det

The XENON1T Dark Matter Experiment

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.

astro-ph.IM

A novel $^{83\mathrm{m}}$Kr tracer method for characterizing xenon gas and cryogenic distillation systems

The radioactive isomer $^{83\mathrm{m}}$Kr has many properties that make it very useful for various applications. Its low energy decay products, like conversion, shake-off and Auger electrons as well as X- and $\gamma$-rays are used for calibration purposes in neutrino mass experiments and direct dark matter detection experiments. Thanks to the short half-life of 1.83 h and the decay to the ground state $^{83}$Kr, one does not risk contamination of any low-background experiment with long- lived radionuclides. In this paper, we present two new applications of $^{83\mathrm{m}}$Kr. It can be used as a radioactive tracer in noble gases to characterize the particle flow inside of gas routing systems. A method of doping $^{83\mathrm{m}}$Kr into xenon gas and its detection, using special custom-made detectors, based on a photomultiplier tube, is described. This technique has been used to determine the circulation speed of gas particles inside of a gas purification system for xenon. Furthermore, 83m Kr can be used to rapidly estimate separation performance of a distillation system.

astro-ph.IM