Search arXivSearch

arXiv subjects

D. Biare

Publications and source records attributed to D. Biare.

11 recordsLinked to original sources

Population of tetraneutron continuum in reactions of $^{8}$He on deuterium

Search for the population of the low-energy continuum of a tetraneutron system was performed for reactions of the $^{8}$He beam on a deuterium target. These studies are based on the data [I.A. Muzalevskii \textit{et al.}, Phys.\ Rev.\ C \textbf{103}, 044313 (2021)], previously used for the studies of $^{7}$H and $^{6}$H in the $^2\text{H}(^8\text{He},{^3\text{He}})^{7}$H and $^2\text{H}(^8\text{He},{^4\text{He}})^{6}$H reactions. Evidence for a hump in the $^4$n continuum at $3.5 \pm 0.7$ and $3.2 \pm 0.8$ MeV was observed in the $^2$H($^8$He,$^6$Li)$^4$n and $^2$H($^8$He,$^3$He)$^7$H$\rightarrow ^3$H+$^4$n reactions, respectively. The observed statistics is quite low (6 events and up to 40 events) corresponding to very low cross sections of few microbarns or tens of microbarns. The background conditions for the $^2$H($^8$He,$^6$Li)$^4$n reaction are shown to be good, favoring the physical nature of the observed events. The $^2$H($^8$He,$^3$He)$^7$H$\rightarrow ^3$H+$^4$n process transforms to the $^2$H($^8$He,$^6$Li$^{\ast})^4n$ reaction in the limit of the highest $^7$H decay energies. The population of the low-energy region in the $^{4}$n spectrum is found to be perfectly correlated with the population of the lowest $^{6}$Li state in the $^{3}$He+$^{3}$H continuum with $E^*=18$ MeV. Theoretical calculations of $^{8}$He in a five-body $\alpha$+$4n$ and of $^{4}$n in a four-body hyperspherical models are presented. The $^{8}$He wave function is shown to contain strong specific correlations, which may give rise to very low-energy structures in tetraneutron continuum in extreme-peripheral reaction scenarios.

nucl-ex

Study of Proton and Deuteron Pickup Reactions 2H(10Be,3He)9Li an 2H(10Be,4He)8Li with 44 A MeV 10Be Radioactive Beam at ACCULINNA-2 Fragment Separator

The proton and deuteron pickup reactions 2H(10Be,3He)9Li and 2H(10Be,4He)8Li radioactive beam produced by the new fragment separator ACCULINNA-2 at FLNR, JINR\@. These measurements were initially motivated as test reactions intended for the elucidation of results obtained in the study of the extremely neutron-rich 7H and 6H systems created in the 2H(10Be,3He)9Li and 2H(10Be,4He)8Li reactions using the same setup. In the 2H(10Be,3He)9Li reaction the 9Li ground-state ($3/2^-$) and its first excited state (2.69MeV, $1/2^-$) were identified in the low-energy region of its excitation spectrum. The differential cross sections for the 9Li g.~s.) population were extracted at forward center-of-mass angles ($3^\circ-13^\circ$) and compared with the FRESCO calculations. Spectroscopic factor of $\sim 1.7$, derived by a model for the 10Be$ = p +$9Li(g.s.) clustering was found in accord with the experimental data. The energy spectrum of 8Li populated in the 2H(10Be,4He)8Li reaction shows the strong peak which corresponds to excitation of the second excited state of 8Li (2.25 MeV, $3^+$). The fact that the ground and the first excited states of 8Li were not observed is fully consistent with Shell-Model calculations carried out for the 10Be g.\,s. and 8Li level structure applying momentum selection rules.

nucl-ex

CUORE Opens the Door to Tonne-scale Cryogenics Experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

physics.ins-det

The $^{6}$H states studied in the $^2\text{He}(^8\text{He},^4\text{He})$ reaction and evidence of extremely correlated character of the $^{5}$H ground state

The extremely neutron-rich system $^{6}$H was studied in the direct $^2\text{H}(^8\text{He},{^4\text{He}})^{6}$H transfer reaction with a $26 A$ MeV secondary $^{8}$He beam. The measured missing mass spectrum shows a broad bump at $\sim 4-8$ MeV above the $^3$H+$3n$ decay threshold. This bump can be interpreted as a broad resonant state in $^{6}$H at $6.8(5)$ MeV. The population cross section of such a presumably $p$-wave state (or may be few overlapping states) in the energy range from 4 to 8 MeV is $d\sigma/d\Omega_{\text{c.m.}} \simeq 190^{+40}_{-80}$ $\mu$b/sr in the angular range $5^{\circ}<\theta_{\text{c.m.}}<16^{\circ}$. The obtained missing mass spectrum is practically free of the $^{6}$H events below 3.5 MeV ($d\sigma/d\Omega_{\text{c.m.}} \lesssim 5$ $\mu$b/sr in the same angular range). The steep rise of the $^{6}$H missing mass spectrum at $\sim 3$ MeV allows to derive the lower limit for the possible resonant-state energy in $^{6}$H to be $4.5(3)$ MeV. According to the paring energy estimates, such a $4.5(3)$ MeV resonance is a realistic candidate for the $^{6}$H ground state (g.s.). The obtained results confirm that the decay mechanism of the $^{7}$H g.s.\ (located at 2.2 MeV above the $^{3}$H+$4n$ threshold) is the "true" (or simultaneous) $4n$ emission. The resonance energy profiles and the momentum distributions of fragments of the sequential $^{6}$H$ \,\rightarrow \, ^5$H(g.s.)+$n\, \rightarrow \, ^3$H+$3n$ decay were analyzed by the theoretically-updated direct four-body-decay and sequential-emission mechanisms. The measured momentum distributions of the $^{3}$H fragments in the $^{6}$H rest frame indicate very strong "dineutron-type" correlations in the $^{5}$H ground state decay.

nucl-ex

Resonant states in $^{7}$H. I. Experimental studies of the $^2$H($^8$He,$^3$He) reaction

The extremely neutron-rich system $^{7}$H was studied in the direct $^2$H($^8$He,$^3$He)$^7$H transfer reaction with a 26 AMeV secondary $^{8}$He beam [Bezbakh et al., Phys. Rev. Lett. 124 (2020) 022502]. The missing mass spectrum and center-of-mass (c.m.) angular distributions of $^{7}$H, as well as the momentum distribution of the $^{3}$H fragment in the $^{7}$H frame, were constructed. In addition to the investigation reported in Ref. [Bezbakh et al., Phys. Rev. Lett. 124 (2020) 022502], we carried out another experiment with the same beam but a modified setup, which was cross-checked by the study of the $^2$H($^{10}$Be,$^3$He$)^{9}$Li reaction. A solid experimental evidence is provided that two resonant states of $^{7}$H are located in its spectrum at 2.2(5) and 5.5(3) MeV relative to the $^3$H+4$n$ decay threshold. Also, there are indications that the resonant states at 7.5(3) and 11.0(3) MeV are present in the measured $^{7}$H spectrum. Based on the energy and angular distributions, obtained for the studied $^2$H($^8$He,$^3$He)$^7$H reaction, the weakly populated 2.2(5) MeV peak is ascribed to the $^7$H ground state. It is highly plausible that the firmly ascertained 5.5(3) MeV state is the $5/2^+$ member of the $^7$H excitation $5/2^+$-$3/2^+$ doublet, built on the $2^+$ configuration of valence neutrons. The supposed 7.5 MeV state can be another member of this doublet, which could not be resolved in Ref. [Bezbakh et al., Phys. Rev. Lett. 124 (2020) 022502]. Consequently, the two doublet members appeared in the spectrum of $^{7}$H in [Bezbakh et al., Phys. Rev. Lett. 124 (2020) 022502] as a single broad 6.5 MeV peak.

nucl-ex

Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.

physics.ins-det

Observation of the $^7$H excited state

The $^7$H system was populated in the $^2$H($^8$He,$^3$He)$^7$H reaction with a 26 AMeV $^8$He beam. The $^{7}$H missing mass energy spectrum, the $^{3}$H energy and angular distributions in the $^7$H decay frame were reconstructed. The $^7$H missing mass spectrum shows a peak which can be interpreted either as unresolved $5/2^+$ and $3/2^+$ doublet or one of these states at 6.5(5) MeV. The data also provide indications on the $1/2^+$ ground state of $^7$H located at 2.0(5) MeV with quite a low population cross section of $\sim 10$ $\mu$b/sr within angular range $\theta_{\text{cm}} \simeq 6^{\circ} - 30^{\circ}$.

nucl-ex

The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures

The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.

physics.ins-det

Radon mitigation during the installation of the CUORE $0\nu\beta\beta$ decay detector

CUORE - the Cryogenic Underground Observatory for Rare Events - is an experiment searching for the neutrinoless double-beta ($0\nu\beta\beta$) decay of $^{130}$Te with an array of 988 TeO$_2$ crystals operated as bolometers at $\sim$10 mK in a large dilution refrigerator. With this detector, we aim for a $^{130}$Te $0\nu\beta\beta$ decay half-life sensitivity of $9\times10^{25}$ y with 5 y of live time, and a background index of $\lesssim 10^{-2}$ counts/keV/kg/y. Making an effort to maintain radiopurity by minimizing the bolometers' exposure to radon gas during their installation in the cryostat, we perform all operations inside a dedicated cleanroom environment with a controlled radon-reduced atmosphere. In this paper, we discuss the design and performance of the CUORE Radon Abatement System and cleanroom, as well as a system to monitor the radon level in real time.

physics.ins-det

First Results from CUORE: A Search for Lepton Number Violation via $0\nu\beta\beta$ Decay of $^{130}$Te

The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0\nu}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0\nu}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{\beta\beta}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.

nucl-ex

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

physics.ins-det