Search arXivSearch

arXiv subjects

D. Fuchs

Publications and source records attributed to D. Fuchs.

At least 19 recordsLinked to original sources

First Measurement of Solar Neutrinos through Elastic Neutrino-Electron Scattering at the keV Scale

We report on the first measurement of low-energy solar neutrinos through elastic neutrino-electron scattering in a dark matter experiment, establishing the lowest energy threshold for any neutrino detection to date. The measurement utilizes data from the first two science runs of XENONnT, corresponding to an exposure of 2.46 t $\cdot$ y, and covers electron recoil energies between 1 keV and 140 keV, providing sensitivity to solar neutrinos with energies down to 17 keV. We reject the background-only hypothesis with a statistical significance of $5.0\sigma$ and measure a solar $pp$ neutrino flux of $(10.2 \pm 2.0) \times 10^{10}$ cm$^{-2}$ s$^{-1}$. The result is larger, but statistically consistent with the previous measurement by Borexino at $1.9\sigma$. Together with recent observations of coherent elastic neutrino-nucleus scattering of $^8$B solar neutrinos in XENONnT and other liquid-xenon time projection chambers, these results demonstrate the growing potential of liquid xenon detectors for neutrino physics down to the keV-scale and represent an important milestone towards a next-generation multipurpose observatory.

hep-ex

Search for Magnetic and Spin-Independent Inelastic Dark Matter with XENONnT

We present a search for Magnetic and Spin-Independent inelastic Dark Matter using 2.1 tonne-years of data from the XENONnT experiment. We consider both single- and double-site event topologies, targeting the unique signature of an initial nuclear recoil followed by a delayed de-excitation photon. To suppress backgrounds, we introduce novel directional and kinematic selections based on the inferred speed and direction of the excited dark matter particle between the scatter and decay sites. We find that the collected data are consistent with background expectations, and report 90% C.L. upper limits for both models across the GeV/c2-TeV/c2 mass range.

hep-ex

Optimization studies of silicon remoTES cryogenic calorimeters

The remoTES design, developed within the COSINUS experiment, enables a broader range of materials to be operated as cryogenic calorimeters read out with Transition Edge Sensors (TESs). In this configuration, the TES is fabricated onto a separate chip and thermally coupled to the absorber via a gold (Au) link. The remoTES concept has been successfully tested on various target materials. To further enhance detector performance and to fully exploit the advantages of the remote coupling design a series of optimization studies has been conducted using silicon (Si) absorbers as benchmark. This work presents an evaluation of several measurements aimed at reducing the thermal boundary resistance and enhancing signal transmission across Si remoTES interfaces, specifically from the absorber to the phonon collector and from the phonon collector to the TES. By testing a new Au link design and three distinct phonon collector configurations, Au, copper, and aluminum (Al)/Au, we achieved a baseline resolution of (21.5 +/- 0.3)eV using the Al/Au phonon collector.

physics.ins-det

Direct Measurement of the $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ Decay Branching Ratios with the XENONnT Experiment

We present precision measurements of $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ decay branching ratios using $^{220}\mathrm{Rn}$ and $^{222}\mathrm{Rn}$ calibration data from the XENONnT detector, a dual-phase liquid xenon time projection chamber. Characterizing these isotopes is critical, as they lead to significant low-energy backgrounds in rare-event searches. We report ground-state branching ratios of $(14.75 \pm 0.20(\mathrm{stat}) ^{+0.14}_{-0.40}(\mathrm{sys}))\%$ for $^{212}\mathrm{Pb}$ and $(9.8 \pm 0.3(\mathrm{stat}) ^{+0.8}_{-0.2}(\mathrm{sys}))\%$ for $^{214}\mathrm{Pb}$, providing the most precise direct measurements of these transitions to date. These results contribute to enhancing background modeling for dark matter and neutrino experiments, improving sensitivity to solar neutrinos and physics beyond the Standard Model.

nucl-ex

Optimisation of TES design for the CRESST experiment

The CRESST experiment aims at the direct detection of sub-GeV dark matter particles via elastic scattering off nuclei in different target crystals at cryogenic temperatures. The advancement in W-TES sensors allowed the CRESST detectors to reach energy thresholds of 10 eV and lower, opening the way to the exploration of dark matter masses as low as 70 MeV/c2. This work presents optimisation studies of W-TESs aimed at further improving the signal-to-noise ratio and overall detector performance. In particular, we investigate the thickness, dimensions and material composition of phonon collectors and assess their impact on detector response. The results demonstrate a significant performance enhancement and establish new benchmarks for the sensors used within CRESST.

physics.ins-det

Probing the Solar $^8$B Neutrino Fog with XENONnT

We report a 3.3 $\sigma$ measurement of coherent elastic neutrino-nucleus scattering from solar $^8$B neutrinos using a 6.77 t$\times$yr exposure from the XENONnT experiment, inferring a solar $^8$B neutrino flux of $(5_{-2}^{+3})\times 10^6\,\mathrm{cm}^{-2}\mathrm{s}^{-1}$, consistent with previous measurements. In the presence of the $^8$B "neutrino fog", we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV/$c^2$ spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at $\sim$ 0.02 GeV/$c$ momentum transfer and constrain physics beyond the Standard Model.

hep-ex

Cosmic Ray Boosted Dark Matter in COSINUS: Modeling and Constraints

Direct detection of nuclear recoils due to sub-GeV dark matter is challenging because of the small kinetic energy of the light dark matter particles. Although limits down to a few hundred MeV have been reached using specially designed low threshold detectors, further improvements are now constrained more by background event rates than by energy thresholds. However, constraints down to sub-MeV dark matter masses can still be obtained through the boosted dark matter framework. In this scenario, high-energy cosmic rays or neutrinos scatter off dark matter particles, imparting additional kinetic energy and boosting them beyond the typical velocities expected from the non-relativistic dark matter halo. These boosted dark matter particles can then be detected even by experiments with higher energy thresholds. In this work, we present a catalog of dark matter - nucleon scattering cross sections corresponding to a heavy mediator limit for spin zero, one half and one dark matter and for scalar and vector mediators with even or odd parity. Based on these results, we present projected constraints on the dark matter - nucleon cross section for the COSINUS experiment, assuming an exposure of 100 kg d, demonstrating the potential sensitivity to sub-GeV boosted dark matter.

hep-ph

Enhancing Neutrinoless Double-Beta Decay Sensitivity of Liquid-Xenon Time Projection Chamber with Augmented Convolutional Neural Network

Dual-phase time projection chamber (TPC) that employs a multi-ton-scale liquid xenon (LXe) target mass is a pioneering detector technology to search for dark matter. Beyond its advantage in dark matter direct detection efforts, the natural xenon target allows it to search for the neutrinoless double-beta decay ($0\nu\beta\beta$) process, which would violate lepton number conservation and indicate that neutrinos are Majorana particles. However, such $0\nu\beta\beta$ searches have been limited by gamma-ray backgrounds originating from the detector materials. In this work, we designed an augmented convolutional neural network (A-CNN) model to extract additional event-topology information from detector data. Using simulation and calibration data from XENONnT, a leading LXe TPC experiment, our model achieved over 60% background rejection while maintaining 90% signal acceptance. This rejection power improves XENONnT's projected sensitivity of the $^{136}$Xe $0\nu\beta\beta$ search by about 40%. The implementation of A-CNN in the data analysis of future liquid xenon observatories, such as XLZD, will further enhance their sensitivities for $0\nu\beta\beta$ with $^{136}$Xe.

physics.ins-det

ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies

We present ImpCresst, a Geant4-based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their response to it. It is tuned for a fast-evolving and heterogeneous detector environment with a focus on physics at the keV range. This tool was originally developed and validated by the CRESST collaboration; however, its flexibility and configurability make it suitable for other experiments with similar requirements. Key features of ImpCresst include the dynamic geometry implementation directly from CAD files, ROOT-based data persistency of the whole event topology and automatic metadata annotation for data provenance, and interfaces to various particle generators, particularly for radiogenic and cosmogenic radionuclides. It includes also a newly developed particle generator for radioactive bulk and surface contaminations which is completely independent of any user defined confinement volumes. The auxiliary tool CresstDS applies detector-specific energy and time resolution based on a user-provided data set of empirical parameterization. We discuss also how to manage an ImpCresst based workflow in an HPC environment based on Apptainer and nextflow.

physics.ins-det

Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT

We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}\nu\text{NS}$) becomes an irreducible background.

hep-ex

Defect Formation in NaI Crystals: A Novel Pathway to Dark Matter Detection

Sodium iodide (NaI) is a widely used scintillator in direct dark matter searches. In particular, NaI-based cryogenic scintillating calorimeters have emerged as promising candidates, like in the COSINUS experiment, for testing the annually modulating signal reported by DAMA/LIBRA. In this study, we investigate defect formation within NaI crystals and its impact on the dark matter detection signal. Using molecular dynamics simulations and density functional theory techniques, we simulate a DM particle collision on an NaI crystal, focusing on the possible defects formation and their structural and electronic properties. Our analysis includes a detailed study of the electronic states associated with the interstitial atoms and vacancies, the energetic cost of defect formation, and the anisotropic threshold displacement energy. Finally, we highlight the potential to exploit dark matter-induced defects as a novel detection channel, enabled by the introduction of new states within the electronic band gap.

hep-ph

Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data

We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level.

hep-ex

Spectral Measurement of the $^{214}$Bi beta-decay to the $^{214}$Po Ground State with XENONnT

We report the measurement of the $^{214}$Bi beta-decay spectrum to the ground state of $^{214}$Po using the XENONnT detector. This decay is classified as first-forbidden non-unique, for which theoretical predictions require detailed nuclear structure modeling. A dedicated identification algorithm isolates a high-purity sample of ground-state beta-decays, explicitly excluding events with associated gamma-rays emission. By comparing the measured spectrum, which covers energies up to 3.27 MeV, with several nuclear models, we find that the prediction based on the conserved vector current (CVC) hypothesis provides the best description of the data. Using this dataset, we additionally derive charge and light yield curves for electronic recoils, extending detector response modeling up to the MeV scale.

nucl-ex

Description of CRESST-II and CRESST-III pulse shape data

A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data cleaning. Here, we describe the data set and how the trained models can be applied to new data. The data and models are available online.

physics.ins-det

Description of CRESST-III lithium aluminate data

Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In this document, we describe how the data set should be used to reproduce our dark matter results.

hep-ex

Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al$_{2}$O$_{3}$ crystal in CRESST-III

The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observation of a peak at (1113.6$^{+6.5}_{-6.5}$)$\,$eV in the data of an Al$_{2}$O$_{3}$ crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this mono-energetic peak to the radiative capture of thermal neutrons on $^{27}$Al and the subsequent de-excitation via single $\gamma$-emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al$_{2}$O$_{3}$ detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.

physics.ins-det

Experimental Observation of Short-Range Magnetic Correlations in Amorphous Nb$_2$O$_5$ and Ta$_2$O$_5$ Thin Films

We use muon spin rotation/relaxation/resonance ($\mu$SR) to investigate the magnetic properties of niobium pentoxide (Nb$_2$O$_5$) and tantalum pentoxide (Ta$_2$O$_5$) thin films. In both oxides, we observe a magnetic response at the lowest available temperature of 2.8 K. This response appears to be structurally dependent: thermally oxidized Ta$_2$O$_5$ with low crystallinity demonstrates suppressed magnetism, while fully amorphous Ta$_2$O$_5$ demonstrates local static magnetism. In contrast, amorphous Nb$_2$O$_5$ is dominated by magnetic fluctuations and is strongly magnetically disordered compared to Ta$_2$O$_5$. Our results suggest that these fundamental differences in the magnetism of Ta and Nb oxides could explain the performance limitations in superconducting qubits and resonators.

cond-mat.other

The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection

Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model particles. To surpass current exclusion limits a new generation of experiments is being developed. The upcoming upgrade of the CRESST experiment will incorporate $\mathcal{O}$(100) detectors with different masses ranging from $\sim$2g to $\sim$24g, aiming to achieve unprecedented sensitivity to sub-GeV dark matter particles with a focus on spin-independent dark matter-nucleus scattering. This paper presents a comprehensive analysis of the planned upgrade, detailed experimental strategies, anticipated challenges, and projected sensitivities. Approaches to address and mitigate low-energy excess backgrounds $-$ a key limitation in previous and current sub-GeV dark matter searches $-$ are also discussed. In addition, a long-term roadmap for the next decade is outlined, including other potential scientific applications.

astro-ph.CO