Search arXiv⌕ Search

arXiv subjects

Daniel Truhn

Publications and source records attributed to Daniel Truhn.

At least 19 recordsLinked to original sources

Auditable Clinical Support with Decision Agents

Clinicians reviewing a diagnostic work-up will ask what was considered at each step and why the assessment changed. Agents powered by free text can reach physician-level diagnostic accuracy, but their written reasoning does not always reflect the factors that went into the decision. Here, we present Decision2Care, a decision agent that works up the acutely ill patient without producing any text. A decision model assigns a probability to each permitted EHR action, and fixed rules carry out the most probable one. We evaluated Decision2Care on the records of 546 emergency admissions across 12 diseases. Decision2Care reached a diagnostic accuracy of 86.5%, compared with 86.1% for the MIRA-v2 agent, and required a median of 2.2 s per work-up, compared with 92-100 s. Each work-up tracked which options Decision2Care was considering at each step. In 10 of the 12 diseases, the differential diagnosis changed most at the test on which the guideline bases the diagnosis. Where Decision2Care was most confident after a single work-up, all but four of its diagnoses were correct (98.5%). We traced each of these four errors back to a single imaging report. Three of them were corrected when that report was removed. The same kind of decision was used to select the treatments, and Decision2Care's drug orders were judged guideline-adherent more often than MIRA-v2's. In emergency patients, its prediction of death was comparable to that of three intensivists on the same cases. In five of the eight intensive care cohorts, it exceeded the best of the three 24-h severity scores within 2-6 h of records. Our results show that decision agents can carry out clinical work-ups while recording the options, probabilities, and execution rules behind each action for audit.

cs.AI↗

What the model knows but does not say: monitoring medical LLMs through verbalized thoughts

Efforts to keep clinical language models safe have concentrated on what enters and leaves the model, but a manipulated model can return an answer that looks entirely ordinary. Here we show that the model's own internal state, rendered in plain language, exposes manipulations the output conceals. Using a natural-language autoencoder, we translate the activations of a multimodal LLM (Gemma-3-27B) into text and let an input-blind judge read this verbalized internal state (the thoughts channel) and the model's answer separately. Across two clinical attack objectives (omitting a pathology, covertly recommending a drug), two input modalities, and two delivery mechanisms, the thoughts channel caught the injection significantly more often than the answer in all eight injected conditions (p<0.05), while both channels held near-zero false-positive rates on clean inputs; the omission result carried over to Llama-3.3-70B. The thoughts channel also registered unsafe clinical requests as harmful while the model was still reading them, before it decided whether to refuse. None of this requires retraining: an off-the-shelf verbalizer and a general-purpose judge are enough.

cs.CL↗

The pretraining domain outweighs the training objective in setting the privacy-utility trade-off of differentially private medical image analysis

Differential privacy limits how much each training image can influence a medical imaging model but lowers its diagnostic accuracy. Pretrained weights reduce this loss. It is unknown whether the pretraining objective or domain improves accuracy more. Here we train chest radiograph classifiers under differential privacy from five starting points on 591,884 radiographs from five datasets. We show that supervised pretraining on chest radiographs ranks first in 24 of 25 combinations of dataset and privacy setting. Measured by the area under the receiver operating characteristic curve, its lead over supervised pretraining on natural images is 2.6% without privacy and 15.3% at the strictest budget. From that starting point, changing the domain improves this area 2.2 to 3.7 times more than changing the objective. Private pretraining on chest radiographs lowers this area by about 5% under privacy but outperforms the three starting points without patient data at the strictest budget. Under privacy, supervised chest radiograph pretraining leads in the worst-performing demographic subgroup.

cs.CV↗

Safety and accuracy diverge across deployment conditions in clinical large language models

Clinical large language models (LLMs) are commonly scaled by increasing model size, context length, retrieval complexity, or inference-time compute, on the assumption that higher accuracy implies safer behavior. In medicine, where a few confident or evidence-contradicting errors can outweigh average performance, this assumption may be incomplete. We introduce Safety-Focused Evaluation of Scaling (SaFE-Scale) and instantiate it on RadSaFE-200, a 200-question text-based radiology multiple-choice benchmark with clinician-defined clean evidence, conflict evidence, and option-level labels for high-risk error, unsafe answer, and evidence contradiction. Thirty-four local LLMs were evaluated across six deployment conditions spanning closed-book, evidence-grounded, standard and agentic retrieval- augmented generation (RAG), and max-context prompting. Clean clinician-written evidence, used as an upper-bound, produced the strongest joint gain, raising mean accuracy from 73.5% to 94.1% and reducing high-risk error from 12.0% to 2.6% and dangerous overconfidence from 8.0% to 1.6%. Standard and agentic RAG, max-context prompting, and inference-time compute improved selected metrics but did not reproduce this safety profile. Clinically, consequential errors concentrated in a small subset of questions, and variance decomposition placed deployment condition above model family on every safety metric. Within this evaluation, clinical LLM safety did not track accuracy scaling but emerged as a deployment-level property.

cs.CL↗

Selective Linkage Precision for Released Medical Vision-Language Models

Hospitals may release de-identified chest radiographs while restricting access to their reports. An attacker who already has reports from the same population and their metadata can use a vision-language model (VLM) to match images to reports. We introduce selective linkage precision, which measures correct matches among the highest-confidence queries after filtering candidates by the available attributes. Across 8 public VLMs and 3 chest radiograph datasets, the maximum whole-pool Recall@1 is 0.40%. However, this metric averages over every query without attribute filtering. On ReXGradient-160K, MedSigLIP-448 reaches 67.68% precision at a budget of 100 after filtering by sex, age band, and projection, with a median of 327 candidate reports. On the same eligible query set, an attribute-only policy reaches 24.99% and the model alone reaches 1.98%. Adding acquisition year, available in only 1 of the 3 datasets, yields 99.05% precision and a median of 24 candidates. Uniform guessing on the observed selected queries has an expected precision of 19.91%. Expanding the primary-setting collection to all 123,100 ReXGradient studies lowers precision to 37.23%. On BioViL-T, the tested head finetuning procedures do not lower linkage below the public checkpoint. Selective linkage precision requires inference without retraining and could help hospitals evaluate which attributes to publish.

cs.CV↗

Automated grounding verification of AI statements about chest radiographs

A grounding verifier checks a statement about a patient's image against the radiology report and the cited evidence. The state-of-the-art methods for testing these verifiers remove or replace the cited evidence while the patient's report stays unchanged. To our knowledge, no existing method checks both the report and the cited evidence. We present Building Report And Citation Examples (BRACE), an automated framework that builds training examples from public radiology reports and Radiopaedia articles. We compared a lexical baseline and 42 verifiers with 0.1-284B parameters on 5 different public chest radiograph datasets. At a threshold accepting 0.90 of the supported test examples, verifiers trained with BRACE accepted a mean of only 0.239 of AI-written statements contradicted by the report. Verifiers trained without contradicted examples passed the state-of-the-art tests, yet accepted most of these statements (0.830 on average). With citations retrieved from held-out Radiopaedia articles, verifiers trained with BRACE accepted 0.169 of AI-written statements with an agreeing report and an unsupporting citation. By contrast, zero-shot large language models mostly checked the report and not the citation (they accepted 0.830 of these statements). We further assessed the framework manually, with two board-certified radiologists independently labeling a sample of test reports. The framework's labels agreed with each radiologist (k > 0.910) almost as closely as the radiologists agreed with each other (k = 0.952). Moreover, instantiating the framework for food allergens in recipes, we showed that it extends beyond clinical applications. A verifier built the same way accepted 0.493 of the statements contradicted by the recipe, whereas a lexical baseline accepted 0.898. Using both the report and the cited evidence, verifiers trained with BRACE could check AI statements before clinicians read them.

cs.CL↗

CANDOR: Chance-Calibrated Neighborhood Discordance in Frozen Encoders for Medical Imaging

In medical imaging, one frozen foundation encoder is often reused for many tasks. The encoder is usually chosen by the area under the receiver operating characteristic curve (AUROC) of a head trained on its features. The AUROC does not measure whether the encoder separates positive from negative images in its feature space. Chance-calibrated neighborhood discordance (CANDOR) measures this separation without training a head. Among images acquired the same way, a positive image is discordant when its k nearest negatives are more similar to it on average than its k nearest positives are. The discordance rate D is the share of discordant positives. When the neighbors come from positive and negative candidate sets of equal size, D has the chance level 1/2 for features without information about the label. With unequal candidate sets, all 11 chest encoders have rates above 1/2 (0.732 to 0.927) on the 12 chest findings of MIMIC-CXR and CheXpert. These rates increase as the finding becomes rarer. With equal sets, the same encoders have rates below 1/2 (0.277 to 0.463). On the chest test split, linear heads miss 0.301 of the discordant positives and 0.165 of the other positives. Across 22 encoders, 605,443 images, and 8 tasks in 7 domains, the best encoder of every task has a rate below 1/2. Because computing D takes one forward pass per image, a hospital can compare candidate encoders before it trains any head.

cs.LG↗

Benchmarking Classification Tasks of Chest X-ray AI Across Multinational Public and Private Datasets: a retrospective diagnostic accuracy study

Chest X-ray (CXR) AI models are increasingly proposed for triage, screening, and rule-out, where the operating point is fixed to miss few abnormalities. Most evaluations instead report threshold-free discrimination on a few public benchmarks, leaving clinically usable performance and generalisability to unseen institutional cohorts poorly characterised. We retrospectively evaluated 10 published CXR classification models on 12 datasets from six countries: seven public benchmarks and five institutional cohorts from China, Japan, and Germany. Models spanned convolutional networks, vision-language models, a question-answering foundation model, and a repurposed encoder. Only image-level classification was assessed; segmentation, detection, and report generation were out of scope. Source labels were harmonised to a common vocabulary. The primary outcome was specificity at 95% sensitivity; PPV at 95% sensitivity and AUROC were secondary outcomes. Estimates weighted each diagnostic task equally, with 95% CIs. MAVL and MedKLIP had the highest overall specificity at 95% sensitivity (0.37 [95% CI 0.31-0.44] and 0.37 [0.30-0.44]) and kept that ranking on tasks evaluable for every model. Their PPV was 0.18 (0.13-0.24) and 0.19 (0.13-0.25): most flagged examinations would be false positives. Specificity was lower on institutional cohorts than on public benchmarks for most models, by 0.13 for MAVL, 0.15 for DenseNet, and 0.09 for MedKLIP. No model was best for every finding, country, lesion extent, or prevalence stratum; specificity fell from 0.34 for diffuse to 0.15 for focal findings. At 95% sensitivity, the best current models clear only about a third of truly negative examinations, and public-benchmark performance overstates what they achieve on unseen institutional data. Operating-point-aware evaluation and external validation on institutional cohorts should precede deployment.

eess.IV↗

Differential privacy representation geometry for medical image analysis

Differential privacy (DP)'s effect in medical imaging is typically evaluated only through end-to-end performance, leaving the mechanism of privacy-induced utility loss unclear. We introduce Differential Privacy Representation Geometry for Medical Imaging (DP-RGMI), a framework that interprets DP as a structured transformation of representation space and decomposes performance degradation into encoder geometry and task-head utilization. Geometry is quantified by representation displacement from initialization and spectral effective dimension, while utilization is measured as the gap between linear-probe and end-to-end utility. Across over 594,000 images from four chest X-ray datasets and multiple pretrained initializations, we show that DP is consistently associated with a utilization gap even when linear separability is largely preserved. At the same time, displacement and spectral dimension exhibit non-monotonic, initialization- and dataset-dependent reshaping, indicating that DP alters representation anisotropy rather than uniformly collapsing features. Correlation analysis reveals that the association between end-to-end performance and utilization is robust across datasets but can vary by initialization, while geometric quantities capture additional prior- and dataset-conditioned variation. These findings position DP-RGMI as a reproducible framework for diagnosing privacy-induced failure modes and informing privacy model selection.

cs.CV↗

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration

cs.CV↗

Medical foundation models converge less under label supervision

Diagnostic classifiers and imaging biomarkers are fitted on the embeddings of medical foundation models. These models are replaced as new versions appear. This practice assumes that different models represent images alike. We tested this assumption with more than 750,000 images from 14 datasets in 5 imaging modalities, 18 public models, and 101 models trained on chest radiographs and histopathology that differ in pretraining objective, label type, size, random seed, initialization, training patients, or training recipe. Agreement was measured as the mutual k-nearest-neighbor overlap, the share of an image's nearest neighbors common to two models. Two public models shared on average 0.091 of the 10 nearest neighbors of a chest radiograph. A randomly initialized network shared 0.036 with them. In the four other modalities, they shared at most 0.300. On chest radiographs, agreement depended more on the source dataset and the radiographic view than on the findings. It was not significantly associated with accuracy. A linear mapping between the embeddings of two models, fitted on 4,096 unlabeled radiographs, transferred classifiers for 14 chest findings with 0.987 of their original area under the receiver operating characteristic curve. Convergence depended on the pretraining objective. Label-supervised models converged least at both model sizes in chest radiography and histopathology. On chest radiographs, two label-supervised models that differed only in their random seed shared 0.062 to 0.100 of their nearest neighbors. Two models trained with self-distillation, masked image modeling, or contrastive pretraining shared 0.411 to 0.802. Developers can therefore choose convergence when they choose the pretraining objective. Before replacing a model, users could test on unlabeled images whether its successor returns the same nearest neighbors.

cs.CV↗

Vision-language models for chest radiography do not always need the image

Vision-language models that answer questions about chest radiographs are evaluated by their accuracy on labels derived from radiology reports. High benchmark accuracy is often interpreted as evidence that the model uses the image. A model that answers from the finding named in the question can score as well as a model that uses the radiograph. Keeping the question fixed, we audit eight open-weight systems by swapping in another patient's radiograph with the same or the opposite label, occluding the radiologist-marked region or an equal region elsewhere, and removing the radiograph or replacing it with noise or a photograph. On 2,548 yes-or-no questions from MIMIC-CXR, one multimodal model answers Yes regardless of the image, another multimodal model changes its answers without following the label, and four systems use the image but keep about half of their correct answers when the radiograph is swapped for an opposite-label radiograph. A medical model that receives only the question text scores 55.3% on the pooled questions, higher than two multimodal systems. It scores 91.8% where every finding is present, and answering Yes to every question scores 100% there. Where the image is necessary, the best multimodal system exceeds this model by 10.4% in balanced accuracy. The categories are unchanged on CheXpert. Confidence is not higher when a correct answer depends on the marked region. In a reader study with three radiologists, the two radiologists who read a balanced set of 200 cases score 86.0% and 82.0%, and the systems score 50.0% to 73.0%. Accuracy does not establish image use, but an intervention on the image can test it.

cs.CV↗

FRAME: Separating sampling variation from performance disparities in medical image analysis

Fairness audits of medical imaging models commonly report the largest performance difference between demographic subgroups and treat any positive value as evidence of bias. Yet a perfectly fair model also produces a positive difference, which grows as subgroups shrink. Some mitigation methods remove demographic information from models because they assume that it produces the difference. Here we introduce Fair-model Reference And Mechanism Evaluation (FRAME). Its first step compares each reported difference with the difference expected from a perfectly fair model at the same subgroup counts. Its second step tests whether candidate causes of any excess over this fair-model reference change the difference when they are injected into model features. We evaluated 36 encoders on nine datasets in three modalities and audited 89 published differences across six modalities. For 10 frozen encoders and 13 chest radiograph findings, the reference is a median 41% of the race difference and 22% of the age difference. It is exceeded by 40 of 53 published differences in sensitivity or false positive rate and by one of 36 in the area under the receiver operating characteristic curve (AUROC). Adding race information to the features of two encoders does not change the race difference significantly. At matched disease performance, mitigation reduces the race difference by less than its spread across three pretraining seeds (medians 0.005 and 0.012) and the age difference by more (0.008 and 0.006). Image-text pretraining raises the worst-group AUROC for race by a median 0.049 over self-supervised pretraining. Reporting the fair-model reference beside every new and published subgroup difference could direct mitigation to the differences above it.

cs.CV↗

Listening for Airway Stenosis: A Foundation Model-Based Method for Rapid and Accessible Detection

Airway stenosis can cause severe respiratory complications, yet its detection often relies on specialized examinations and medical imaging. This study explores the potential of acoustic AI for rapid and accessible airway stenosis detection using readily acquired patient voice recordings. We systematically investigate whether acoustic foundation models (AFMs) can extract acoustic representations associated with airway stenosis-related speech patterns. Experiments are conducted on a cohort of 748 participants from the Bridge2AI-Voice dataset, 134 with airway stenosis and 614 without. The best-performing model achieves an AUROC of 0.952 and an accuracy of 0.924 (means over five-fold cross-validation), highlighting the potential of AFMs to transfer beyond general-purpose speech applications to clinical diagnostic tasks. Further analysis reveals that the model primarily relies on connected-speech recordings rather than isolated acoustic tasks, such as sustained phonation and breathing. Overall, these results suggest that voice-based acoustic AI could complement existing diagnostic workflows by enabling rapid, low-burden, and widely accessible screening for airway stenosis.

cs.SD↗

Auditable CT Phenotyping Through Report-derived Radiological Observations

Medical image foundation models can predict clinical phenotypes from computed tomography (CT), but strong performance leaves open whether they read disease-specific findings or shortcuts that correlate with the diagnosis. We tested this in 221 electronic-health-record (EHR) phenotypes using Auditable CT phenotyping (ACT), built on report-derived radiological observations. We trained ACT on 38,317 patients, mined 376,194 observations and evaluated it in 25,183 held-out patients. ACT exceeded five vision-language baselines on zero-shot annotation, and CT-CLIP across 221 phenotypes from unseen CT pulmonary angiography, both under zero-shot scoring (0.651 versus 0.572) and under linear probing (0.709 versus 0.662). Reading each probe exposes what accuracy conceals: only 97 observations occupy the 221 rank-1 positions, and one phrase describing aortic and coronary calcification ranks first for 20 phenotypes, including osteoporosis, urinary tract infection and major depressive disorder. Restricting the bank to clinician-specified evidence redirects those probes onto phenotype-related observations in 86 phenotypes at no accuracy cost (0.751 versus 0.741). Accurate CT-based EHR phenotyping can therefore rest on observations that are not valid evidence for the coded phenotype and that ACT can identify and intervene on.

cs.CV↗

Bayesian uncertainty estimation improves clinical decision making in medical AI agents

Machine learning models for medical image analysis typically lack a reliable measure of confidence, limiting their use in ambiguous or atypical cases. Here we show that Monte Carlo dropout, applied to a multi-task chest-radiograph classifier (eight thoracic findings, 137,593 training images), provides an epistemic uncertainty signal that tracks generalisation across training-set scales and flags confident yet error-prone predictions. Adding this signal to the point prediction raised error-detection AUROC from 0.74 to 0.77 ($Δ$AUROC +0.023, 95% CI [+0.014, +0.033]). In a controlled 2x2 factorial experiment, a clinical-decision-support agent exploited this uncertainty only when it was delivered as a binary error-risk flag rather than as raw scores, cutting confident misdiagnoses on unreliable findings from 8.5% to 2.7%. Epistemic uncertainty estimation thus carries decision-relevant information beyond point predictions, but its value for downstream agents depends on how it is communicated.

cs.LG↗

Foundation-model-guided radiogenomic discovery linking cancer genomes to cancer scans

The function of many genes is still unknown, and conventional driver-discovery methods, which rely on how frequently a gene is mutated, cannot assess genes that are only rarely affected. Here we pair Evo~2-based genome analysis with routine clinical imaging to identify gene--phenotype associations at genome-wide scale. For every somatic mutation across three TCGA cohorts (cRCC=clear cell renal cell carcinoma, HCC=hepatocellular carcinoma, and BC=breast cancer; $n = 340$ total), Evo~2 predicts a severity score, with no task-specific training. Per-gene severity summaries are then correlated with radiomic features extracted from paired tumor segmentations, controlling for total mutation burden. In TCGA-cRCC ($n = 162$), this sweep recovers established renal-cancer drivers and identifies 46 additional genes reaching false discovery rate (FDR) significance absent from curated cancer-gene panels, several of which are Mendelian ciliopathy and cytoskeletal-disease genes. These results demonstrate that pairing a genomic language model with widely available clinical imaging can serve as a hypothesis-free discovery tool for gene--imaging associations invisible to conventional approaches.

q-bio.GN↗

Can Agents Distinguish Visually Hard-to-Separate Diseases in a Zero-Shot Setting? A Pilot Study

The rapid progress of multimodal large language models (MLLMs) has led to increasing interest in agent-based systems. While most prior work in medical imaging concentrates on automating routine clinical workflows, we study an underexplored yet clinically significant setting: distinguishing visually hard-to-separate diseases in a zero-shot setting. We benchmark representative agents on two imaging-only proxy diagnostic tasks, (1) melanoma vs. atypical nevus and (2) pulmonary edema vs. pneumonia, where visual features are highly confounded despite substantial differences in clinical management. We introduce a multi-agent framework based on contrastive adjudication. Experimental results show improved diagnostic performance (an 11-percentage-point gain in accuracy on dermoscopy data) and reduced unsupported claims on qualitative samples, although overall performance remains insufficient for clinical deployment. We acknowledge the inherent uncertainty in human annotations and the absence of clinical context, which further limit the translation to real-world settings. Within this controlled setting, this pilot study provides preliminary insights into zero-shot agent performance in visually confounded scenarios.

cs.CV↗