Search arXivSearch

arXiv subjects

H. Chen

Publications and source records attributed to H. Chen.

At least 19 recordsLinked to original sources

The NOvA Test Beam Experiment

NOvA is a long-baseline neutrino oscillation experiment designed to study the neutrino mixing parameters, mass ordering, and CP violation in the lepton sector. A key component of the success of the experiment is a robust understanding of the systematic uncertainties associated with detector response and calibration. To address this, NOvA deployed a Test Beam experiment at the Fermilab Test Beam Facility, which collected data from April 2019 through July 2022. The NOvA Test Beam experiment used a 30-ton segmented liquid scintillator detector functionally identical to the NOvA Near and Far Detectors to analyze tagged particles produced from p-Cu collisions, with instrumentation capable of selecting and identifying electrons, muons, pions, kaons, and protons with momentum ranging from 0.4-1.5GeV/c. Analysis of the collected data provides a better understanding of the largest systematic uncertainties impacting NOvA's analyses, which include the detector response, energy calibration, and hadronic and electromagnetic energy resolutions.

hep-ex

NOvA Dual-Baseline Search for Active-to-Sterile Neutrino Oscillations using Neutrino- and Antineutrino-Enriched Samples

We report a search for neutrino oscillations to sterile neutrinos in the NOvA detectors under a model with three active and one sterile neutrinos. This search simultaneously fits data in the two NOvA detectors and is the first from NOvA to use both neutrino- and antineutrino-mode beams, with exposures of $26.61\times10^{20}$ and $12.50\times10^{20}$ protons on target, respectively. There is no evidence for sterile neutrinos in the data and we are able to exclude regions of parameter space that were allowed by previous experiments, including most of the allowed region reported by IceCube.

hep-ex

Neutron detector response modeling in NOvA

Neutrons can present a significant challenge for neutrino experiments in which energy reconstruction is critical. With the ability to escape detection completely and with a weak correlation between their kinetic energy and any eventual energy deposition, it is difficult to fully account for neutrons produced in neutrino interactions. This in turn leads to significant model dependence when evaluating neutron-related systematic uncertainties. The NOvA experiment is a long-baseline neutrino oscillation experiment with a high-statistics sample of antineutrino data collected by its near detector. We report an excess relative to data of simulated neutron candidates with low energy depositions when using standard Geant4 physics lists. The simulation excess is traced to an overabundance of secondary photons produced from interactions of neutrons with kinetic energy greater than \SI{20}{\mega\eV}. Improved agreement with data is obtained by applying the data-driven neutron-on-carbon \menate model for neutrons between \SI{20}{\mega\eV} and ${\sim}$\SI{100}{\mega\eV}. With \menate, the residual oversimulation is more uniform across the calorimetric neutron energy spectrum, suggesting possible overproduction of primary neutrons by the GENIE neutrino interaction generator. These results motivate the adoption of \menate-supplemented Geant4 simulation as the nominal simulation in the production of future \nova simulation.

hep-ex

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

physics.ins-det

Flow-dependent tagging of $^{214}$Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag \UChPb~ beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0\% of exposure, target the decay of each \UChPb~ atom up to 81 minutes after production, resulting in (63~$\pm$~6$_{(\mathrm{stat})}$~$\pm$~7$_{(\mathrm{sys})}$)\% identification of \UChPb~decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data. Finally we report updated estimates of radon-chain charge branching fractions in liquid xenon, finding branching to $^{218}$Po$^+$ at $0.49 \pm 0.01$, $^{214}$Pb$^+$ at $0.48 \pm 0.12$, and $^{214}$Bi$^+$ at $0.74 \pm 0.05$, with a mean charged ion lifetime in the LZ TPC of $49 \pm 4$ min.

physics.ins-det

Quality control and quality assurance evaluation of ALFE2, a large-dynamic-range front-end ASIC de-veloped for the ATLAS Liquid Argon Calorimeter high-luminosity LHC upgrade

ALFE2 is a front-end ASIC developed for the ATLAS Liquid Argon (LAr) Calorimeter upgrade during the High-Luminosity Large Hadron Collider (HL-LHC) phase. ALFE2 comprises four preamplifier/shaper channels, each providing two distinct gain outputs to cover a 16-bit dynamic range. A robotic system has been developed for the automatic quality control test of ALFE2, and over 10% of the 80,000 chips have been evaluated by September 2025. The evaluation has allowed us to establish grading criteria. Using these criteria, a yield of over 85% was achieved in the evaluation tests, and these criteria are now being applied to the ongoing full-production QC. Irradiation tests were also performed for the quality assurance of ALFE2. No significant performance degradation was observed during the total-ionizing-dose (TID) test. Based on the single-event effect (SEE) test results, an error rate of fewer than 4.6 single-event upsets (SEUs) per day is extrapolated for the entire ATLAS LAr Calorimeter during HL-LHC operation.

physics.ins-det

Search for New Physics via Low-Energy Electron Recoils with a 4.2 Tonne\times Year Exposure from the LZ Experiment

We report results from searches for new physics models through electron recoils using data collected by the LUX-ZEPLIN (LZ) experiment during its first two science runs, with a total exposure of 4.2 tonne-years. The observed data are consistent with a background-only hypothesis. Constraints are derived for electromagnetic interactions of solar neutrinos, solar axion-like particles (ALPs), mirror dark matter, and the absorption of bosonic dark matter candidates. The inverse Primakoff process for 57Fe de-excitation solar ALPs is considered for the first time. These results represent the most stringent constraints to date on keV-scale Primakoff and 57Fe solar ALPs, bosonic dark matter, mirror dark matter, and neutrino millicharge, while remaining competitive for the other signal models investigated.

hep-ex

Strange metallicity encompasses high magnetic field-induced superconductivity in UTe2

A strange metallic state - characterized by an electrical resistivity that rises linearly in temperature $T$ at a rate governed by Planckian energetic dissipation - is present in a number of unconventional superconductors. Despite widespread investigative efforts, the microscopic properties of strange metallicity continue to defy elementary description. Here we investigate heavy fermion UTe$_2$, which hosts a suite of exotic spin-triplet superconducting phases, the most extreme of which resides in a narrow angular window of intense magnetic fields $>$ 40 T. Through angle-dependent magnetotransport measurements in pulsed magnetic fields, we find that this superconductive phase emerges from a strange metallic state with Planckian $T$-linear resistivity confined to a small region of phase space where the field-induced superconductivity is strongest, suggesting a shared underlying mechanism. These findings reveal a novel setting for strange metallicity - in contrast to the general case of singlet superconductivity emerging on the border of antiferromagnetism, here strange metallicity accompanies field-induced triplet superconductivity within a spin-polarized magnetic state. This result demonstrates the remarkable ubiquity of strange metallicity across diverse materials settings, and highlights UTe$_2$ as a unique platform for exploring the interplay between unconventional superconductivity and quantum criticality.

cond-mat.str-el

Searches for Light Dark Matter and Evidence of Coherent Elastic Neutrino-Nucleus Scattering of Solar Neutrinos with the LUX-ZEPLIN (LZ) Experiment

We present searches for light dark matter (DM) with masses 3-9 GeV/$c^2$ in the presence of coherent elastic neutrino-nucleus scattering (CE$ν$NS) from $^{8}$B solar neutrinos with the LUX-ZEPLIN experiment. This analysis uses a 5.7 tonne-year exposure with data collected between March 2023 and April 2025. In an energy range spanning 1-6 keV, we report no significant excess of events attributable to dark matter nuclear recoils, but we observe a significant signal from $^{8}$B CE$ν$NS interactions that is consistent with expectation. We set world-leading limits on spin-independent and spin-dependent-neutron DM-nucleon interactions for masses down to 5 GeV/$c^2$. In the no-dark-matter scenario, we observe a signal consistent with $^{8}$B CE$ν$NS events, corresponding to a $4.5σ$ statistical significance. This is the most significant evidence of $^{8}$B CE$ν$NS interactions and is enabled by robust background modeling and mitigation techniques. This demonstrates LZ's ability to detect rare signals at keV-scale energies.

hep-ex

Absolute Calibration of a Time-Resolved High Resolution X-ray Spectrometer for the National Ignition Facility (invited)

A high resolution, Diagnostic Instrument Manipulator (DIM)-based x-ray Bragg crystal spectrometer has been calibrated for and deployed at the National Ignition Facility (NIF) to diagnose plasma conditions in ignition capsules near stagnation times. The spectrometer has two conical crystals in the Hall geometry focusing rays from the Kr He$α$, Ly$α$, and He$β$ complexes onto a streak camera, with the physics objectives of measuring time-resolved electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. A third von Hámos crystal that time-integrates the Kr He$α$, He$β$ and intervening energy range provides in-situ calibration for the streak camera signals. The spectrometer has been absolutely calibrated using a microfocus x-ray source, an array of CCD and single-photon-counting detectors, and multiple K- and L-absorption edge filters at the Princeton Plasma Physics Laboratory (PPPL) x-ray laboratory. Measurements of the integrated reflectivity, energy range, and energy resolution for each crystal are discussed. These calibration data provide absolute x-ray signal levels for NIF measurements, enabling precise filter selection and comparisons to simulations.

physics.plasm-ph

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility (NIF). The capsules were filled with DD gas with trace levels of Kr, and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He$β$ spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. These advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

physics.plasm-ph

Production and installation of wavelength-shifting reflective light enhancers for the Short-Baseline Near Detector

We report on the design, production, and installation of a wavelength-shifting reflective system on the cathode of the Short-Baseline Near Detector (SBND), a liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam. To increase and homogenize scintillation-light collection, 64 double-sided plates were fabricated from FR4, laminated with specular reflector film and coated with 300 $μ$g/cm$^2$ of tetraphenyl butadiene (TPB) wavelength shifter using controlled physical vapor deposition. The coating uniformity was validated through dedicated measurements of deposited mass and profilometry studies. Because exposure to ambient blue/UV light could degrade the TPB, protective filtering and controlled storage conditions were implemented during handling and installation. The coated plates were assembled between conductive meshes for high-voltage compatibility and installed in situ during detector integration. This system constitutes the largest TPB-coated area deployed in a neutrino detector. It operates in conjunction with SBND's photon detection system, which consists of photomultiplier tubes and X-ARAPUCAs. Early light-collection measurements show high uniformity and light response across the detector, supporting improved triggering, calorimetry, and position reconstruction in SBND.

physics.ins-det

GUP-corrected black holes: Thermodynamic properties, evaporation time and shadow constraint from EHT Observations of M87* and Sgr A*

In this manuscript, we implement the generalized uncertainty principle (GUP) with linear and quadratic moment for Schwarzschild black hole metric in order to study the influence of quantum effect on the thermodynamics and evaporation of black hole. To this end, we first derive the GUP-modified Hawking temperature of a black hole in the semi-classical framework. Due to the existence of the GUP effect, there is a maximum Hawking temperature. We determine the entropy, heat capacity and Helmholtz free energy with heuristic analysis that investigates the particle absorbed by black hole. Furthermore, we also verify that these quantities are modified by the GUP, the influence of quantum effect on the black hole phase transition is discussed in detail. Then, we analyze the black hole evaporation process in the mentioned framework and examine the obtained results by graphical methods and compare them with each other. We likewise explore the behavior of the event horizon radius, photon sphere radius, and shadow silhouette when influenced by the GUP-corrected Schwarzschild black hole (GCSBH) parameters. We intend to establish restrictions for $α$ by utilizing the event horizon telescope (EHT) data for M87* and Sagittarius A* (Sgr A*). Our findings show that Sgr A* provides more robust constraints. As the parameter $β$ grows, the range of constraints for $α$ expands. For Sgr A* one, we find that the shadow radius is close to the observed value at smaller values of $α$.

gr-qc

Precision measurement of positron decay modes of Xe-125 in the LUX-ZEPLIN experiment

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but positron emission has been confirmed by direct measurement to at least the 243 keV level of $^{125}\text{I}$. An additional decay to the 188keV level is expected from triple-coincident measurements of the annihilation and relaxation $γ$ rays, but has not been directly confirmed. By utilizing multiple-scatter event analysis and the pre-activation data to constrain backgrounds, this work reports positron emission with a statistical significance of 5.5$σ$. This corresponds to a total branching ratio of $0.29\pm0.08_{\text{stat.}}\pm0.04_{\text{sys.}}$ %, and is the first constraint to the individual branching levels of $^{125}\text{I}$.

hep-ex

Sampling Off-Axis Neutrino Fluxes with the Short-Baseline Near Detector

The Short-Baseline Near Detector (SBND), the near detector in the Short-Baseline Neutrino Program at Fermi National Accelerator Laboratory, is located just 110 m from the Booster Neutrino Beam target. Thanks to this close proximity, relative to its 4 m $\times$ 4 m front face, neutrinos enter SBND over a range of angles from $0^{\circ}$ to approximately $1.6^{\circ}$, enabling the detector to sample variations in the neutrino flux as a function of angle-a technique known as PRISM, referred to here as SBND-PRISM. In this paper, we show how muon- and electron-neutrino fluxes vary as a function of the neutrino beam axis angle and how this can be exploited to expand the physics potential of SBND. We make use of a model that predicts an angle-dependent electron-neutrino excess signal to illustrate this effect, such as $ν_μ\to ν_e$ oscillations. We present how SBND-PRISM provides a method to add robustness against uncertainties in cross-section modeling and, more generally, uncertainties that do not depend on the spatial position of neutrino interaction inside the detector. The fluxes, along with their associated covariance matrices, are made publicly available with this publication.

hep-ex

Constraints on ultraheavy dark matter from the CDEX-10 experiment at the China Jinping Underground Laboratory

We report a search for ultraheavy dark matter (UHDM) with the CDEX-10 experiment at the China Jinping Underground Laboratory. Using a Monte Carlo framework that incorporates Earth shielding effects, we simulated UHDM propagation and energy deposition in p-type point-contact germanium detectors. Analysis of 205.4 kg$\cdot$day exposure in the 0.16--4.16 keVee range showed no excess above background. Our results exclude the spin-independent UHDM-nucleon scattering with two cross section scales, with the UHDM mass from $10^6$ to $10^{11}$ GeV, and provide the most stringent constraints with solid-state detectors below $10^8$ GeV.

hep-ex

Study of few-electron backgrounds in the LUX-ZEPLIN detector

The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/$c^2$--TeV/$c^2$ Weakly Interacting Massive Particles (WIMPs), it is also capable of measuring low-energy ionization signals down to a single electron that may be produced by scatters of sub-GeV/$c^2$ dark matter. The major challenge in exploiting this sensitivity is to understand and suppress the ionization background in the few-electron regime. We report a characterization of the delayed electron backgrounds following energy depositions in the LZ detector under different detector conditions. In addition, we quantify the probability for photons to be emitted in coincidence with electron emission from the high voltage grids. We then demonstrate that spontaneous grid electron emission can be identified and rejected with a high efficiency using a coincident photon tag, which provides a tool to improve the sensitivity of future dark matter searches.

physics.ins-det

Low-Energy Radon Backgrounds from Electrode Grids in Dual-Phase Xenon TPCs

The dual-phase xenon time projection chamber (TPC) is a powerful technology to detect rare interactions such as scatters of dark matter particles on nuclei. In particular, the built-in gain of ionization signals in a dual-phase TPC makes it sensitive to events in the few-electron regime, as expected from low-mass dark matter interactions. The pursuit of this low-energy sensitivity through ionization-only signal detection has so far been hindered by excessive electron backgrounds observed across experiments. Much of this background is attributed to the plate-out of $^{222}$Rn decay chain isotopes on the high voltage electrode grid surfaces that span the full cross section of the TPC. This work presents a first-principle model constructed for this background, the predictions of which are consistent with data from the LZ and LUX experiments. We then discuss mitigation strategies of this background in future dual-phase TPCs and the possibility of applying this grid background model to ionization-only dark matter searches.

hep-ex