Search arXivSearch

arXiv subjects

H. Fuke

Publications and source records attributed to H. Fuke.

At least 19 recordsLinked to original sources

Precision spectral measurements of Chromium and Titanium from 10 to 250 GeV$/n$ and sub-Iron to Iron ratio with the Calorimetric Electron Telescope on the ISS

The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray (CR) iron and sub-iron events over a wide energy interval. In this paper we report an update of our previous measurement of the iron flux and we present - for the first time - a high statistics measurement of the spectra of two sub-iron elements Cr and Ti in the energy interval from 10 to 250 GeV/n. The analyses are based on 8 years of data. Differently from older generations of cosmic-ray instruments which, in most cases, could not resolve individual sub-iron elements, CALET can identify each nuclear species from proton to nickel (and beyond) with a measurement of their electric charge. Thanks to the improvement in statistics and a more refined assessment of systematic uncertainties, the iron spectral shape is better resolved, at high energy, than in our previous paper and we report its flux ratio to chromium and titanium. The measured fluxes of Cr and Ti show energy dependences compatible with a single power law with spectral indices $-2.74 \pm 0.06$ and $-2.88 \pm 0.06$, respectively.

astro-ph.HE

Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the TeV Region with CALET on the International Space Station

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10$^5$), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from -3.15 to -3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron + positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

astro-ph.HE

Charge-Sign Dependent Cosmic-Ray Modulation Observed with the Calorimetric Electron Telescope on the International Space Station

We present the observation of a charge-sign dependent solar modulation of galactic cosmic rays (GCRs) with the CALorimetric Electron Telescope onboard the International Space Station over 6 yr, corresponding to the positive polarity of the solar magnetic field. The observed variation of proton count rate is consistent with the neutron monitor count rate, validating our methods for determining the proton count rate. It is observed by the CALorimetric Electron Telescope that both GCR electron and proton count rates at the same average rigidity vary in anticorrelation with the tilt angle of the heliospheric current sheet, while the amplitude of the variation is significantly larger in the electron count rate than in the proton count rate. We show that this observed charge-sign dependence is reproduced by a numerical ``drift model'' of the GCR transport in the heliosphere. This is a clear signature of the drift effect on the long-term solar modulation observed with a single detector.

astro-ph.HE

Direct Measurement of the Cosmic-Ray Helium Spectrum from 40 GeV to 250 TeV with the Calorimetric Electron Telescope on the International Space Station

We present the results of a direct measurement of the cosmic-ray helium spectrum with the CALET instrument in operation on the International Space Station since 2015. The observation period covered by this analysis spans from October 13, 2015 to April 30, 2022 (2392 days). The very wide dynamic range of CALET allowed to collect helium data over a large energy interval, from ~40 GeV to ~250 TeV, for the first time with a single instrument in Low Earth Orbit. The measured spectrum shows evidence of a deviation of the flux from a single power-law by more than 8$\sigma$ with a progressive spectral hardening from a few hundred GeV to a few tens of TeV. This result is consistent with the data reported by space instruments including PAMELA, AMS-02, DAMPE and balloon instruments including CREAM. At higher energy we report the onset of a softening of the helium spectrum around 30 TeV (total kinetic energy). Though affected by large uncertainties in the highest energy bins, the observation of a flux reduction turns out to be consistent with the most recent results of DAMPE. A Double Broken Power Law (DBPL) is found to fit simultaneously both spectral features: the hardening (at lower energy) and the softening (at higher energy). A measurement of the proton to helium flux ratio in the energy range from 60 GeV/n to about 60 TeV/n is also presented, using the CALET proton flux recently updated with higher statistics.

astro-ph.HE

Cosmic-ray Boron Flux Measured from 8.4 GeV$/n$ to 3.8 TeV$/n$ with the Calorimetric Electron Telescope on the International Space Station

We present the measurement of the energy dependence of the boron flux in cosmic rays and its ratio to the carbon flux \textcolor{black}{in an energy interval from 8.4 GeV$/n$ to 3.8 TeV$/n$} based on the data collected by the CALorimetric Electron Telescope (CALET) during $\sim 6.4$ years of operation on the International Space Station. An update of the energy spectrum of carbon is also presented with an increase in statistics over our previous measurement. The observed boron flux shows a spectral hardening at the same transition energy $E_0 \sim 200$ GeV$/n$ of the C spectrum, though B and C fluxes have different energy dependences. The spectral index of the B spectrum is found to be $\gamma = -3.047\pm0.024$ in the interval $25 < E < 200$ GeV$/n$. The B spectrum hardens by $\Delta \gamma_B=0.25\pm0.12$, while the best fit value for the spectral variation of C is $\Delta \gamma_C=0.19\pm0.03$. The B/C flux ratio is compatible with a hardening of $0.09\pm0.05$, though a single power-law energy dependence cannot be ruled out given the current statistical uncertainties. A break in the B/C ratio energy dependence would support the recent AMS-02 observations that secondary cosmic rays exhibit a stronger hardening than primary ones. We also perform a fit to the B/C ratio with a leaky-box model of the cosmic-ray propagation in the Galaxy in order to probe a possible residual value $\lambda_0$ of the mean escape path length $\lambda$ at high energy. We find that our B/C data are compatible with a non-zero value of $\lambda_0$, which can be interpreted as the column density of matter that cosmic rays cross within the acceleration region.

astro-ph.HE

Observation of Spectral Structures in the Flux of Cosmic-Ray Protons from 50 GeV to 60 TeV with the Calorimetric Electron Telescope on the International Space Station

A precise measurement of the cosmic-ray proton spectrum with the Calorimetric Electron Telescope (CALET) is presented in the energy interval from 50 GeV to 60 TeV, and the observation of a softening of the spectrum above 10 TeV is reported. The analysis is based on the data collected during $\sim$6.2 years of smooth operations aboard the International Space Station and covers a broader energy range with respect to the previous proton flux measurement by CALET, with an increase of the available statistics by a factor of $\sim$2.2. Above a few hundred GeV we confirm our previous observation of a progressive spectral hardening with a higher significance (more than 20 sigma). In the multi-TeV region we observe a second spectral feature with a softening around 10 TeV and a spectral index change from =2.6 to -2.9 consistently, within the errors, with the shape of the spectrum reported by DAMPE. We apply a simultaneous fit of the proton differential spectrum which well reproduces the gradual change of the spectral index encompassing the lower energy power-law regime and the two spectral features observed at higher energies.

astro-ph.HE

CALET Search for electromagnetic counterparts of gravitational waves during the LIGO/Virgo O3 run

The CALorimetric Electron Telescope (CALET) on the International Space Station (ISS) consists of a high-energy cosmic ray CALorimeter (CAL) and a lower-energy CALET Gamma ray Burst Monitor (CGBM). CAL is sensitive to electrons up to 20 TeV, cosmic ray nuclei from Z = 1 through Z $\sim$ 40, and gamma rays over the range 1 GeV - 10 TeV. CGBM observes gamma rays from 7 keV to 20 MeV. The combined CAL-CGBM instrument has conducted a search for gamma ray bursts (GRBs) since Oct. 2015. We report here on the results of a search for X-ray/gamma ray counterparts to gravitational wave events reported during the LIGO/Virgo observing run O3. No events have been detected that pass all acceptance criteria. We describe the components, performance, and triggering algorithms of the CGBM - the two Hard X-ray Monitors (HXM) consisting of LaBr$_{3}$(Ce) scintillators sensitive to 7 keV to 1 MeV gamma rays and a Soft Gamma ray Monitor (SGM) BGO scintillator sensitive to 40 keV to 20 MeV - and the high-energy CAL consisting of a CHarge-Detection module (CHD), IMaging Calorimeter (IMC), and fully active Total Absorption Calorimeter (TASC). The analysis procedure is described and upper limits to the time-averaged fluxes are presented.

astro-ph.HE

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/n to 240 GeV/n with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other trans-iron elements, therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than $ \sim$ 3 GeV/n are available at present in the literature and they are affected by strong limitations in both energy reach and statistics. In this paper we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number $ Z $ = 40). The particle's energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This paper follows our previous measurement of the iron spectrum [O. Adriani et al., Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV$ /n $ our present data are compatible within the errors with a single power law with spectral index $ -2.51 \pm 0.07 $.

astro-ph.HE

Statistical investigation of the large-area Si(Li) detectors mass-produced for the GAPS experiment

The lithium-drifted silicon (Si(Li)) detector developed for the General Antiparticle Spectrometer (GAPS) experiment features a thick (~2.2 mm) sensitive layer, large (10 cm) diameter, and excellent energy resolution (~4 keV for 20-100 keV X-rays) at a relatively high operating temperature (approximately -40C). Mass production of GAPS Si(Li) detectors has been performed to construct a large-volume silicon tracker for GAPS. We achieved the first success of the mass production of large-area Si(Li) detectors with a high (~90%) yield rate. Valuable datasets related to detector fabrication, such as detector performance and manufacturing parameters, were recorded and collected during the mass production. This study analyzes the datasets using statistical methods with the aim of comprehensively examining the mass production and to gain valuable insight into the fabrication method. Sufficient uniformities of the performance parameters (leakage current and capacitance) between detectors and strips are found, demonstrating high-quality and stable mass production. We also search for correlations between detector performance and manufacturing parameters by using data-mining techniques. Conventional multivariate analysis (multiple regression analysis) and machine-learning techniques (regression tree analysis) are complementarily used, and it is found that the Li-drift process makes a significant contribution to the performance parameters of the finished detectors. Detailed investigation of the drift process is performed using environmental data, and physical interpretations are presented. Our results provide valuable insight into the fabrication methods for this kind of large-area Si(Li) detector, and encourages future projects that require large-volume silicon trackers.

physics.ins-det

Measurement of the Iron Spectrum in Cosmic Rays from 10 GeV$/n$ to 2.0 TeV$/n$ with the Calorimetric Electron Telescope on the International Space Station

The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray iron over a wide energy interval. In this Letter a measurement of the iron spectrum is presented in the range of kinetic energy per nucleon from 10 GeV$/n$ to 2.0 TeV$/n$ allowing the inclusion of iron in the list of elements studied with unprecedented precision by space-borne instruments. The measurement is based on observations carried out from January 2016 to May 2020. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number $Z$ = 40). The energy is measured by a homogeneous calorimeter with a total equivalent thickness of 1.2 proton interaction lengths preceded by a thin (3 radiation lengths) imaging section providing tracking and energy sampling. The analysis of the data and the detailed assessment of systematic uncertainties are described and results are compared with the findings of previous experiments. The observed differential spectrum is consistent within the errors with previous experiments. In the region from 50 GeV$/n$ to 2 TeV$/n$ our present data are compatible with a single power law with spectral index -2.60 $\pm$ 0.03.

astro-ph.HE

Direct Measurement of the Cosmic-Ray Carbon and Oxygen Spectra from 10 GeV$/n$ to 2.2 TeV$/n$ with the Calorimetric Electron Telescope on the International Space Station

In this paper, we present the measurement of the energy spectra of carbon and oxygen in cosmic rays based on observations with the Calorimetric Electron Telescope (CALET) on the International Space Station from October 2015 to October 2019. Analysis, including the detailed assessment of systematic uncertainties, and results are reported. The energy spectra are measured in kinetic energy per nucleon from 10 GeV$/n$ to 2.2 TeV$/n$ with an all-calorimetric instrument with a total thickness corresponding to 1.3 nuclear interaction length. The observed carbon and oxygen fluxes show a spectral index change of $\sim$0.15 around 200 GeV$/n$ established with a significance $>3\sigma$. They have the same energy dependence with a constant C/O flux ratio $0.911\pm 0.006$ above 25 GeV$/n$. The spectral hardening is consistent with that measured by AMS-02, but the absolute normalization of the flux is about 27% lower, though in agreement with observations from previous experiments including the PAMELA spectrometer and the calorimetric balloon-borne experiment CREAM.

astro-ph.HE

Cosmic antihelium-3 nuclei sensitivity of the GAPS experiment

The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1$-$0.3 GeV/$n$) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based on the formation, decay, and annihilation of exotic atoms, provides greater identification power for these low-energy antinuclei than previous magnetic spectrometer experiments. This work reports the sensitivity of GAPS to detect antihelium-3 nuclei, based on full instrument simulation, event reconstruction, and realistic atmospheric influence simulations. The report of antihelium nuclei candidate events by AMS-02 has generated considerable interest in antihelium nuclei as probes of dark matter and other beyond the Standard Model theories. GAPS is in a unique position to detect or set upper limits on the cosmic antihelium nuclei flux in an energy range that is essentially free of astrophysical background. In three 35-day long-duration balloon flights, GAPS will be sensitive to an antihelium flux on the level of $1.3^{+4.5}_{-1.2}\cdot 10^{-6}\mathrm{m^{-2}sr^{-1}s^{-1}}(\mathrm{GeV}/n)^{-1}$ (95% confidence level) in the energy range of 0.11$-$0.3 GeV/$n$, opening a new window on rare cosmic physics.

hep-ph

Cosmic-ray Antinuclei as Messengers of New Physics: Status and Outlook for the New Decade

The precise measurement of cosmic-ray antinuclei serves as an important means for identifying the nature of dark matter and other new astrophysical phenomena, and could be used with other cosmic-ray species to understand cosmic-ray production and propagation in the Galaxy. For instance, low-energy antideuterons would provide a "smoking gun" signature of dark matter annihilation or decay, essentially free of astrophysical background. Studies in recent years have emphasized that models for cosmic-ray antideuterons must be considered together with the abundant cosmic antiprotons and any potential observation of antihelium. Therefore, a second dedicated Antideuteron Workshop was organized at UCLA in March 2019, bringing together a community of theorists and experimentalists to review the status of current observations of cosmic-ray antinuclei, the theoretical work towards understanding these signatures, and the potential of upcoming measurements to illuminate ongoing controversies. This review aims to synthesize this recent work and present implications for the upcoming decade of antinuclei observations and searches. This includes discussion of a possible dark matter signature in the AMS-02 antiproton spectrum, the most recent limits from BESS Polar-II on the cosmic antideuteron flux, and reports of candidate antihelium events by AMS-02; recent collider and cosmic-ray measurements relevant for antinuclei production models; the state of cosmic-ray transport models in light of AMS-02 and Voyager data; and the prospects for upcoming experiments, such as GAPS. This provides a roadmap for progress on cosmic antinuclei signatures of dark matter in the coming years.

astro-ph.HE

GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays

The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significantly below those predicted by well-motivated, beyond the standard model theories. GAPS will also conduct low-energy antiproton and antihelium searches. Combined, these observations will provide a powerful search for dark matter and provide the best observations to date on primordial black hole evaporation on Galactic length scales. The GAPS instrument detects antinuclei using the novel exotic atom technique. It consists of a central tracker with a surrounding time-of-flight (TOF) system. The tracker is a one cubic meter volume containing 10 cm-diameter lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator system that will both trigger the Si(Li) tracker and enable better reconstruction of particle tracks. After coming to rest in the tracker, antinuclei will form an excited exotic atom. This will then de-excite via characteristic X-ray transitions before producing a pion/proton star when the antiparticle annihilates with the nucleus. This unique event topology will give GAPS the nearly background-free detection capability required for a rare-event search. Here we present the scientific motivation for the GAPS experiment, its design and its current status as it prepares for flight in the austral summer of 2021-22.

astro-ph.IM

Developing a mass-production model of large-area Si(Li) detectors with high operating temperatures

This study presents a fabrication process for lithium-drifted silicon (Si(Li)) detectors that, compared to previous methods, allows for mass production at a higher yield, while providing a large sensitive area and low leakage currents at relatively high temperatures. This design, developed for the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment, has an overall diameter of 10 cm, with ~9 cm of active area segmented into 8 readout strips, and an overall thickness of 2.5 mm, with $\gtrsim$2.2 mm ($\gtrsim$90%) sensitive thickness. An energy resolution $\lesssim$4 keV full-width at half-maximum (FWHM) for 20-100 keV X-rays is required at the operating temperature ~-40C, which is far above the liquid nitrogen temperatures conventionally used to achieve fine energy resolution. High-yield production is also required for GAPS, which consists of $\gtrsim$1000 detectors. Our specially-developed Si crystal and custom methods of Li evaporation, diffusion and drifting allow for a thick, large-area and uniform sensitive layer. We find that retaining a thin undrifted layer on the p-side of the detector drastically reduces the leakage current, which is a dominant component of the energy resolution at these temperatures. A guard-ring structure and optimal etching of the detector surface are also confirmed to suppress the leakage current. We report on the mass production of these detectors that is ongoing now, and demonstrate it is capable of delivering a high yield of ~90%.

physics.ins-det

Direct Measurement of the Cosmic-Ray Proton Spectrum from 50 GeV to 10 TeV with the Calorimetric Electron Telescope on the International Space Station

In this paper, we present the analysis and results of a direct measurement of the cosmic-ray proton spectrum with the CALET instrument onboard the International Space Station, including the detailed assessment of systematic uncertainties. The observation period used in this analysis is from October 13, 2015 to August 31, 2018 (1054 days). We have achieved the very wide energy range necessary to carry out measurements of the spectrum from 50 GeV to 10 TeV covering, for the first time in space, with a single instrument the whole energy interval previously investigated in most cases in separate subranges by magnetic spectrometers (BESS-TeV, PAMELA, and AMS-02) and calorimetric instruments (ATIC, CREAM, and NUCLEON). The observed spectrum is consistent with AMS-02 but extends to nearly an order of magnitude higher energy, showing a very smooth transition of the power-law spectral index from -2.81 +- 0.03 (50--500 GeV) neglecting solar modulation effects (or -2.87 +- 0.06 including solar modulation effects in the lower energy region) to -2.56 +- 0.04 (1--10 TeV), thereby confirming the existence of spectral hardening and providing evidence of a deviation from a single power law by more than 3 sigma.

astro-ph.HE

The CALorimetric Electron Telescope (CALET) on the International Space Station: Results from the First Two Years On Orbit

The CALorimetric Electron Telescope (CALET) is a high-energy astroparticle physics space experiment installed on the International Space Station (ISS), developed and operated by Japan in collaboration with Italy and the United States. The CALET mission goals include the investigation of possible nearby sources of high-energy electrons, of the details of galactic particle acceleration and propagation, and of potential signatures of dark matter. CALET measures the cosmic-ray electron + positron flux up to 20 TeV, gamma-rays up to 10 TeV, and nuclei with Z=1 to 40 up to 1,000 TeV for the more abundant elements during a long-term observation aboard the ISS. Starting science operation in mid-October 2015, CALET performed continuous observation without major interruption with close to 20 million triggered events over 10 GeV per month. Based on the data taken during the first two-years, we present an overview of CALET observations: uses w/o major interruption 1) Electron + positron energy spectrum, 2) Nuclei analysis, 3) Gamma-ray observation including a characterization of on-orbit performance. Results of the electromagnetic counterpart search for LIGO/Virgo gravitational wave events are discussed as well.

astro-ph.HE