Search arXivSearch

arXiv subjects

I. Modena

Publications and source records attributed to I. Modena.

18 recordsLinked to original sources

Dark Matter searches using gravitational wave bar detectors: quark nuggets and newtorites

Many experiments have searched for supersymmetric WIMP dark matter, with null results. This may suggest to look for more exotic possibilities, for example compact ultra-dense quark nuggets, widely discussed in literature with several different names. Nuclearites are an example of candidate compact objects with atomic size cross section. After a short discussion on nuclearites, the result of a nuclearite search with the gravitational wave bar detectors Nautilus and Explorer is reported. The geometrical acceptance of the bar detectors is 19.5 $\rm m^2$ sr, that is smaller than that of other detectors used for similar searches. However, the detection mechanism is completely different and is more straightforward than in other detectors. The experimental limits we obtain are of interest because, for nuclearites of mass less than $10^{-5}$ g, we find a flux smaller than that one predicted considering nuclearites as dark matter candidates. Particles with gravitational only interactions (newtorites) are another example. In this case the sensitivity is quite poor and a short discussion is reported on possible improvements.

physics.ins-det

Quark nuggets search using 2350 Kg gravitational waves aluminum bar detectors

The gravitational wave resonant detectors can be used as detectors of quark nuggets, like nuclearites (nuclear matter with a strange quark). This search has been carried out using data from two 2350 Kg, 2 K cooled, aluminum bar detectors: NAUTILUS, located in Frascati (Italy), and EXPLORER, that was located in CERN Geneva (CH). Both antennas are equipped with cosmic ray shower detectors: signals in the bar due to showers are continuously detected and used to characterize the antenna performances. The bar excitation mechanism is based on the so called thermo-acoustic effect, studied on dedicated experiments that use particle beams. This mechanism predicts that vibrations of bars are induced by the heat deposited in the bar from the particle. The geometrical acceptance of the bar detectors is 19.5 $\rm m^2$ sr, that is smaller than that of other detectors used for similar searches. However, the detection mechanism is completely different and is more straightforward than in other detectors. We will show the results of ten years of data from NAUTILUS (2003-2012) and 7 years from EXPLORER (2003-2009). The experimental limits we obtain are of interest because, for nuclearites of mass less than $10^{-4}$ grams, we find a flux smaller than that one predicted considering nuclearites as dark matter candidates.

astro-ph.HE

Analysis of 3 years of data from the gravitational wave detectors EXPLORER and NAUTILUS

We performed a search for short gravitational wave bursts using about 3 years of data of the resonant bar detectors Nautilus and Explorer. Two types of analysis were performed: a search for coincidences with a low background of accidentals (0.1 over the entire period), and the calculation of upper limits on the rate of gravitational wave bursts. Here we give a detailed account of the methodology and we report the results: a null search for coincident events and an upper limit that improves over all previous limits from resonant antennas, and is competitive, in the range h_rss ~1E-19, with limits from interferometric detectors. Some new methodological features are introduced that have proven successful in the upper limits evaluation.

gr-qc

All-sky search of NAUTILUS data

A search for periodic gravitational-wave signals from isolated neutron stars in the NAUTILUS detector data is presented. We have analyzed half a year of data over the frequency band $<922.2; 923.2>$ Hz, the spindown range $<-1.463\times10^{-8}; 0>$ Hz/s and over the entire sky. We have divided the data into 2 day stretches and we have analyzed each stretch coherently using matched filtering. We have imposed a low threshold for the optimal detection statistic to obtain a set of candidates that are further examined for coincidences among various data stretches. For some candidates we have also investigated the change of the signal-to-noise ratio when we increase the observation time from two to four days. Our analysis has not revealed any gravitational-wave signals. Therefore we have imposed upper limits on the dimensionless gravitational-wave amplitude over the parameter space that we have searched. Depending on frequency, our upper limit ranges from $3.4 \times 10^{-23}$ to $1.3 \times 10^{-22}$. We have attempted a statistical verification of the hypotheses leading to our conclusions. We estimate that our upper limit is accurate to within 18%.

gr-qc

Detection of high energy cosmic rays with the resonant gravitational wave detector NAUTILUS and EXPLORER

The cryogenic resonant gravitational wave detectors NAUTILUS and EXPLORER, made of an aluminum alloy bar, can detect cosmic ray showers. At temperatures above 1 K, when the material is in the normal conducting state, the measured signals are in good agreement with the values expected based on the cosmic rays data and on the thermo-acoustic model. When NAUTILUS was operated at the temperature of 0.14 K, in superconductive state, large signals produced by cosmic ray interactions, more energetic than expected, were recorded. The NAUTILUS data in this case are in agreement with the measurements done by a dedicated experiment on a particle beam. The biggest recorded event was in EXPLORER and excited the first longitudinal mode to a vibrational energy of about 670 K, corresponding to about 360 TeV absorbed in the bar. Cosmic rays can be an important background in future acoustic detectors of improved sensitivity. At present, they represent a useful tool to verify the gravitational wave antenna performance.

hep-ex

Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light

A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7 lt) dedicated detector, coupled with a system for the injection of controlled amounts of gaseous Oxygen. Purpose of the test with the 0.7 lt detector is to detect the reduction of the long-lived component lifetime of the Argon scintillation light emission at increasing O2 concentration. Data from the WArP prototype are used for determining the behavior of both the ionization electron lifetime and the scintillation long-lived component lifetime during the O2-purification process activated in closed loop during the acquisition run. The electron lifetime measurements allow to infer the O2 content of the Argon and correlate it with the long-lived scintillation lifetime data. The effect of Oxygen contamination on the scintillation light has been thus measured over a wide range of O2 concentration, spanning from about 10^-3 ppm up to about 10 ppm. The rate constant of the light quenching process induced by Oxygen in LAr has been found to be k'(O2)=0.54+-0.03 micros^-1 ppm^-1.

nucl-ex

Effects of Nitrogen contamination in liquid Argon

A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. Purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from about 10^-1 ppm up to about 10^3 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (gamma-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. The rate constant of the light quenching process induced by Nitrogen in liquid Ar has been found to be k(N2)=0.11 micros^-1 ppm^-1. Direct PMT signals acquisition at high time resolution by fast Waveform recording allowed to extract with high precision the main characteristics of the scintillation light emission in pure and contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable from O(1 ppm) of Nitrogen concentrations.

nucl-ex

All-sky incoherent search for periodic signals with Explorer 2005 data

The data collected during 2005 by the resonant bar Explorer are divided into segments and incoherently summed in order to perform an all-sky search for periodic gravitational wave signals. The parameter space of the search spanned about 40 Hz in frequency, over 23927 positions in the sky. Neither source orbital corrections nor spindown parameters have been included, with the result that the search was sensible to isolated neutron stars with a frequency drift less than 6 X 10^{-11} Hz/s. No gravitational wave candidates have been found by means of the present analysis, which led to a best upper limit of 3.1 X 10^{-23} for the dimensionless strain amplitude.

gr-qc

Studying the coincidence excess between EXPLORER and NAUTILUS during 1998

The coincidences between EXPLORER and NAUTILUS during 1998 (Astone et al. 2001) are more deeply studied. It is found that the coincidence excess is greater in the ten-day period 7-17 September 1998 and it occurs at the sidereal hour 4, when the detectors axes are perpendicular to the Galactic Disk. The purpose of this paper is to bring our results with the GW detectors to the attention of scientists working in the astrophysical field, and ask them whether are they aware of any special phenomenon occurring when EXPLORER and NAUTILUS showed a coincidence excess.

astro-ph

Cumulative analysis of the association between the gravitational wave detectors NAUTILUS and EXPLORER and the gamma-ray bursts detected by BATSE and BeppoSAX

The statistical association between the output of the Gravitational Wave (GW) detectors EXPLORER and NAUTILUS and a list of Gamma Ray Bursts (GRBs) detected by the satellite experiments BATSE and BeppoSAX has been analyzed using cumulative algorithms. GW detector data collected between 1991 and 1999 have been correlated to the GRB flux peak times. The cumulative analysis of a large number of GRBs (387) allows to push the upper bound for the corresponding GW burst amplitude down to $h = 2.5\cdot10^{-19}$.

astro-ph

Comments on the 2001 run of the EXPLORER/NAUTILUS gravitational wave experiment

The recently published analysis of the coincidences between the EXPLORER and NAUTILUS gravitational wave detectors in the year 2001 (Astone et al. 2002) has drawn some criticism (Finn 2003). We do not hold with these objections, even if we agree that no claim can be made with our data. The paper we published reports data of unprecedented quality and sets a new procedure for the coincidence search, which can be repeated again by us and by other groups in order to search for signature of possible signals. About the reported coincidence excess, we remark that it is not destined to remain an intriguing observation for long: it will be confirmed or denied soon by interferometers and bars operating at their expected sensitivity.

gr-qc

Increasing the bandwidth of resonant gravitational antennas: The case of Explorer

Resonant gravitational wave detectors with an observation bandwidth of tens of hertz are a reality: the antenna Explorer, operated at CERN by the ROG collaboration, has been upgraded with a new read-out. In this new configuration, it exhibits an unprecedented useful bandwidth: in over 55 Hz about its frequency of operation of 919 Hz the spectral sensitivity is better than 10^{-20} /sqrt(Hz) . We describe the detector and its sensitivity and discuss the foreseable upgrades to even larger bandwidths.

gr-qc

Study of the coincidences between the gravitational wave detectors EXPLORER and NAUTILUS in 2001

We report the result from a search for bursts of gravitational waves using data collected by the cryogenic resonant detectors EXPLORER and NAUTILUS during the year 2001, for a total measuring time of 90 days. With these data we repeated the coincidence search performed on the 1998 data (which showed a small coincidence excess) applying data analysis algorithms based on known physical characteristics of the detectors. With the 2001 data a new interesting coincidence excess is found when the detectors are favorably oriented with respect to the Galactic Disk.

gr-qc

Search for correlation between GRB's detected by BeppoSAX and gravitational wave detectors EXPLORER and NAUTILUS

Data obtained during five months of 2001 with the gravitational wave (GW) detectors EXPLORER and NAUTILUS were studied in correlation with the gamma ray burst data (GRB) obtained with the BeppoSAX satellite. During this period BeppoSAX was the only GRB satellite in operation, while EXPLORER and NAUTILUS were the only GW detectors in operation. No correlation between the GW data and the GRB bursts was found. The analysis, performed over 47 GRB's, excludes the presence of signals of amplitude h >=1.2 * 10^{-18}, with 95 % probability, if we allow a time delay between GW bursts and GRB within +-400 s, and h >= 6.5 * 10^{-19}, if the time delay is within +- 5 s. The result is also provided in form of scaled likelihood for unbiased interpretation and easier use for further analysis.

astro-ph

Effect of cosmic rays on the resonant gravitational wave detector NAUTILUS at temperature T=1.5 K

The interaction between cosmic rays and the gravitational wave bar detector NAUTILUS is experimentally studied with the aluminum bar at temperature of T=1.5 K. The results are compared with those obtained in the previous runs when the bar was at T=0.14 K. The results of the run at T = 1.5 K are in agreement with the thermo-acoustic model; no large signals at unexpected rate are noticed, unlike the data taken in the run at T = 0.14 K. The observations suggest a larger efficiency in the mechanism of conversion of the particle energy into vibrational mode energy when the aluminum bar is in the superconductive status.

gr-qc

Energetic Cosmic Rays observed by the resonant gravitational wave detector NAUTILUS

Cosmic ray showers interacting with the resonant mass gravitational wave antenna NAUTILUS have been detected. The experimental results show large signals at a rate much greater than expected. The largest signal corresponds to an energy release in NAUTILUS of 87 TeV. We remark that a resonant mass gravitational wave detector used as particle detector has characteristics different from the usual particle detectors, and it could detect new features of cosmic rays. Among several possibilities, one can invoke unexpected behaviour of superconducting Aluminium as particle detector, producing enhanced signals, the excitation of non-elastic modes with large energy release or anomalies in cosmic rays (for instance, the showers might include exotic particles as nuclearites or Q-balls). Suggestions for explaining these observations are solicited.

gr-qc

Study of Coincidences between Resonant Gravitational Wave Detectors

Coincidences are searched with the cryogenic resonant gravitational wave detectors EXPLORER and NAUTILUS, during a period of about six months (2 June-14 December 1998) for a total measuring time of 94.5 days, with the purpose to study new algorithms of analysis, based on the physical characteristics of the detectors.

gr-qc

Initial operation of the International Gravitational Event Collaboration

The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is not complete, in the years 1997 and 1998 up to four detectors were operating simultaneously. Preliminary results are mentioned.

astro-ph