Search arXiv⌕ Search

arXiv subjects

Inhwa Son

Publications and source records attributed to Inhwa Son.

3 recordsLinked to original sources

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

cs.CV↗

Decouple and Reason: Anatomically Guided Two-Stage Voxel-Level Grounding of Free-Text Findings in 3D Chest CT

Automatic voxel-level grounding of free-text findings in 3D chest Computed Tomography (CT) is critical for clinical interpretability. However, this task remains highly challenging due to the intricate spatial complexity of large 3D volumes and the heterogeneity of free-text findings. Existing end-to-end approaches often struggle to simultaneously learn the localized feature representations required for accurate 3D segmentation and the complex semantic understanding needed for text alignment, leading to suboptimal grounding performance. To overcome this fundamental limitation, we propose a novel decoupled framework that disentangles the problem into two specialized stages: (1) class-agnostic lesion segmentation and (2) text-volume reasoning. This structural separation allows the model to first extract candidate sub-volumes by localizing potential abnormalities. Subsequently, intensive cross-modal reasoning is performed to align these localized sub-volumes with free-text medical findings. To resolve the spatial ambiguities inherent in local regions, the reasoning module is augmented with explicit anatomical guidance, utilizing relative spatial coordinates and lung lobe priors. Evaluated on the ReXGroundingCT benchmark, our method achieves state-of-the-art performance in overall grounding quality on the official leaderboard. These results demonstrate that decoupling detection from reasoning is a highly effective paradigm for handling the complexity of 3D medical visual grounding. Our code is publicly available at https://github.com/khuhm/DAGG.

cs.CV↗

Lesion Segmentation in Moderate to Severe Traumatic Brain Injury: An nnU-Net Based Approach with Adaptive Normalization in the AIMS-TBI 2025 Challenge

The segmentation of lesions in Moderate to Severe Traumatic Brain Injury (msTBI) from T1-weighted MRI presents a significant clinical challenge due to the profound heterogeneity of lesion characteristics in terms of size, shape, and location. To address this, the AIMS-TBI 2025 Challenge was organized to promote the development of robust and accurate segmentation algorithms. In this paper, we present our deep learning-based solution. Our methodology employs the nnU-Net framework with an adaptive intensity normalization strategy confined to the brain parenchyma, effectively reducing inter-subject variability and mitigating artifacts from non-brain structures. Upon final evaluation on the held-out test set, our method demonstrated highly competitive performance on the official leaderboard, achieving an Overall Dice Coefficient of 0.6305. The model obtained a Dice score of 0.4805 for lesion segmentation and 0.9324 for non-lesion tissue. While the lesion Dice reflects the difficulty of detecting highly heterogeneous lesions, the high non-lesion Dice primarily indicates the model's strong ability to correctly identify non-lesion voxels, demonstrating good specificity in differentiating lesion from non-lesion regions. These results demonstrate that incorporating anatomically constrained normalization within the nnU-Net pipeline is a powerful and effective strategy for tackling the complexities of msTBI lesion segmentation.

cs.CV↗