Search arXiv⌕ Search

arXiv subjects

John Daniels

Publications and source records attributed to John Daniels.

3 recordsLinked to original sources

An Open-Source Web-Based Viewer for Disseminating Image-Derived Models

Patient-specific 3-dimensional (3D) models are increasingly central to planning surgery and catheter-based intervention in children with congenital heart disease (CHD), whose anatomy is often atypical and variable. These models inform care only when the surgeons and interventional cardiologists who make treatment decisions can rotate, crop, and measure them directly. Desktop modeling applications require local installation, capable hardware, and training. Commercial web-based viewers are portable but closed, and, in our experience, cannot display volume rendering, time-resolved (e.g., 4-dimensional) data, or the custom workflows centers build for CHD. Because CHD populations are small and heterogeneous, such workflows are unlikely to be prioritized commercially, and end users have no means to add them. To address these limitations, we developed the SlicerHeart Viewer, an open-source module that presents a simplified interface to a complete 3D Slicer/SlicerHeart session running on a server. Clinicians access models created by clinical modeling services from any device through a web browser. Because 3D Slicer runs underneath, volume rendering, time-resolved data, and any SlicerHeart workflow, including those developed for CHD, are available without modification. The module is independent of the hosting environment; we chose internal servers behind institutional single sign-on, and a cloud-hosted option is in development. Over one year at a single pediatric center, nearly all of 82 modeled cases were shared through the Viewer with clinicians from five specialties, with cases loading in 5 to 10 seconds. The approach is not specific to CHD and is deployable at other centers.

q-bio.QM↗

Ultrahigh electrostrain in Pb-free piezoceramics: Effect of bending

Recently several reports showing ultra-high electrostrain (> 1 %) have appeared in Pb-free piezoceramics. However, there is lack of clarity on the nature of the ultrahigh strain. Here, we demonsrate that the ultrahigh strain is a consequence of bending of the disc. We show that the propensity for bending arises from the difference in the response magnitude of the grains at the positive and negative surfaces of the piezoceramic when the field is applied.

physics.app-ph↗

Convolutional Recurrent Neural Networks for Glucose Prediction

Control of blood glucose is essential for diabetes management. Current digital therapeutic approaches for subjects with Type 1 diabetes mellitus (T1DM) such as the artificial pancreas and insulin bolus calculators leverage machine learning techniques for predicting subcutaneous glucose for improved control. Deep learning has recently been applied in healthcare and medical research to achieve state-of-the-art results in a range of tasks including disease diagnosis, and patient state prediction among others. In this work, we present a deep learning model that is capable of forecasting glucose levels with leading accuracy for simulated patient cases (RMSE = 9.38$\pm$0.71 [mg/dL] over a 30-minute horizon, RMSE = 18.87$\pm$2.25 [mg/dL] over a 60-minute horizon) and real patient cases (RMSE = 21.07$\pm$2.35 [mg/dL] for 30-minute, RMSE = 33.27$\pm$4.79\% for 60-minute). In addition, the model provides competitive performance in providing effective prediction horizon ($PH_{eff}$) with minimal time lag both in a simulated patient dataset ($PH_{eff}$ = 29.0$\pm$0.7 for 30-min and $PH_{eff}$ = 49.8$\pm$2.9 for 60-min) and in a real patient dataset ($PH_{eff}$ = 19.3$\pm$3.1 for 30-min and $PH_{eff}$ = 29.3$\pm$9.4 for 60-min). This approach is evaluated on a dataset of 10 simulated cases generated from the UVa/Padova simulator and a clinical dataset of 10 real cases each containing glucose readings, insulin bolus, and meal (carbohydrate) data. Performance of the recurrent convolutional neural network is benchmarked against four algorithms. The proposed algorithm is implemented on an Android mobile phone, with an execution time of $6$ms on a phone compared to an execution time of $780$ms on a laptop.

cs.CV↗