Search arXivSearch

arXiv subjects

K. Raymond

Publications and source records attributed to K. Raymond.

7 recordsLinked to original sources

Characterization of external cross-talk from silicon photomultipliers in a liquid xenon detector

The Light-only Liquid Xenon experiment (LoLX) employs a small-scale detector equipped with 96 Hamamatsu VUV4 silicon photomultipliers (SiPMs) submerged in 5 kg of liquid xenon (LXe) to perform characterization measurements of light production, transport and detection in xenon. In this work, we perform a novel measurement of the "external cross-talk" (ExCT) of SiPMs, where photons produced in the avalanche process escape the device and produce correlated signals on other SiPMs. SiPMs are the photodetector technology of choice for next generation rare-event search experiments; understanding the sources and effects of correlated noise in SiPMs is critical for producing accurate estimates of detector performance and sensitivity projections. We measure the probability to observe ExCT through timing correlation of detected photons in low-light conditions within LoLX. Measurements of SiPM ExCT are highly detector dependent; thus the ExCT process is simulated and modelled using the Geant4 framework. Using the simulation, we determine the average transport and detection efficiency for ExCT photons within LoLX, a necessary input to extract the expected ExCT probability from the data. For an applied overvoltage of 4 V and 5 V, we measure a mean number of photons emitted into the LXe per avalanche of $0.5^{+0.3}_{-0.2}$ and $0.6^{+0.3}_{-0.2}$, respectively. Using an optical model to describe photon transmission through the SiPM surface, this corresponds to an estimated photon yield inside the bulk silicon of $20^{+11}_{-9}$ and $25^{+12}_{-9}$ photons per avalanche. The relative increase in intensity of SiPM ExCT emission between 4 V and 5 V is consistent with expectation for the linear increase of gain with respect to overvoltage.

physics.ins-det

Development of a $^{127}$Xe calibration source for nEXO

We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0\nu\beta\beta$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0\nu\beta\beta$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

physics.ins-det

Characterisation of SiPM Photon Emission in the Dark

In this paper, we report on the photon emission of Silicon Photomultipliers (SiPMs) from avalanche pulses generated in dark condition, with the main objective of better understanding the associated systematics for next-generation, large area, SiPM-based physics experiments. A new apparatus for spectral and imaging analysis was developed at TRIUMF and used to measure the light emitted by the two SiPMs considered as photo-sensor candidates for the nEXO neutrinoless double-beta decay experiment: one Fondazione Bruno Kessler (FBK) VUV-HD Low Field (LF) Low After Pulse (Low AP) (VUV-HD3) SiPM, and one Hamamatsu Photonics K.K. (HPK) VUV4 Multi-Pixel Photon Counter (MPPC). Spectral measurements of their light emission were taken with varying over-voltage in the wavelength range of 450--1020\,nm. For the FBK VUV-HD3, at an over-voltage of $12.1\pm1.0$\,V, we measure a secondary photon yield (number of photons ($\gamma$) emitted per charge carrier ($e^{-}$)) of $(4.04\pm0.02)\times 10^{-6}$ $\gamma/e^{-}$. The emission spectrum of the FBK VUV-HD3 contains an interference pattern consistent with thin-film interference. Additionally, emission microscopy images (EMMIs) of the FBK VUV-HD3 show a small number of highly localized regions with increased light intensity (hotspots) randomly distributed over the SiPM surface area. For the HPK VUV4 MPPC, at an over-voltage of $10.7\pm1.0$\,V, we measure a secondary photon yield of $(8.71\pm0.04)\times 10^{-6}$ $\gamma/e^{-}$. In contrast to the FBK VUV-HD3, the emission spectra of the HPK VUV4 don't show an interference pattern -- most likely due to a thinner surface coating. EMMIs of the HPK VUV4 also reveal a larger number of hotspots compared to the FBK VUV-HD3, especially in one of the corners of the device.

physics.ins-det

Spectroscopic studies of neutron-rich $^{129}$In and its $\beta$-decay daughter, $^{129}$Sn, using the GRIFFIN spectrometer

The $\beta$-decay of neutron-rich $^{129}$In into $^{129}$Sn was studied using the GRIFFIN spectrometer at the ISAC facility at TRIUMF. The study observed the half-lives of the ground state and each of the $\beta$-decaying isomers. The level scheme of $^{129}$Sn has been expanded with thirty-one new $\gamma$-ray transitions and nine new excited levels, leading to a re-evaluation of the $\beta$-branching ratios and level spin assignments. The observation of the $\beta$-decay of the (29/2$^{+}$) 1911-keV isomeric state in $^{129}$In is reported for the first time, with a branching ratio of 2.0(5)$\%$.

nucl-ex

Absence of Low-Energy Shape Coexistence in $^{80}$Ge: The Nonobservation of a Proposed Excited 0$_2^+$ Level at 639 keV

The $^{80}$Ge structure was investigated in a high-statistics $\beta$-decay experiment of $^{80}$Ga using the GRIFFIN spectrometer at TRIUMF-ISAC through $\gamma$, $\beta$-$e$, $e$-$\gamma$ and $\gamma$-$\gamma$ spectroscopy. No evidence was found for the recently reported 0$_2^{+}$ 639-keV level suggested as evidence for low-energy shape coexistence in $^{80}$Ge. Large-scale shell model calculations performed in $^{78,80,82}$Ge place the $0^{+}_{2}$ level in $^{80}$Ge at 2\,MeV. The new experimental evidence combined with shell model predictions indicate that low-energy shape coexistence is not present in $^{80}$Ge.

nucl-ex

Collective 2p-2h intruder states in $^{118}$Sn studied via $\beta$-decay of $^{118}$In using GRIFFIN

The low-lying structure of semi-magic $^{118}$Sn has been investigated through the $\beta$-decay of $^{118}$In ($T_{1/2}=4.45$ min) to study shape coexistence via the reduced transition probabilities of states in the 2p-2h proton intruder band. This high-statistics study was carried out at TRIUMF-ISAC with the GRIFFIN spectrometer. In total, 99 transitions have been placed in the level scheme with 43 being newly observed. Three low-lying $\gamma$-ray transitions with energies near 285 keV have been resolved from which the 2$^+_{\mathrm{intr.}} \rightarrow 0^+_{\mathrm{intr.}}$ 284.52-keV transition was determined to have half of the previous branching fraction leading to a $B(E2;2^+_2\rightarrow 0^+_2)$ of 21(4) W.u. compared to 39(7) W.u. from the previous measurement. Calculations using $sd$ IBM-2 with mixing have also been made to compare the experimental $B(E2)$ values to the theoretical values and to make comparisons to the $^{114,116}$Sn isotopes previously studied using the same theoretical model.

nucl-ex

The GRIFFIN Facility for Decay-Spectroscopy Studies at TRIUMF-ISAC

Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new high-efficiency $\gamma$-ray spectrometer designed for use in decay spectroscopy experiments with low-energy radioactive ion beams provided by TRIUMF's Isotope Separator and Accelerator (ISAC-I) facility. GRIFFIN is composed of sixteen Compton-suppressed large-volume clover-type high-purity germanium (HPGe) $\gamma$-ray detectors combined with a suite of ancillary detection systems and coupled to a custom digital data acquisition system. The infrastructure and detectors of the spectrometer as well as the performance characteristics and the analysis techniques applied to the experimental data are described.

physics.ins-det