A closed-loop agentic research environment for MRI development within Siemens IDEA platform

Motivation: Testing new ideas in MRI can require substantial effort to learn sequence programming and reconstruction tools and to debug implementations before the scientific question can be addressed. Goals: Reduce the implementation and debugging burden of testing MRI ideas while retaining researcher control of scientific decisions. Approach: We developed an environment where LLM agents develop sequences in the native Siemens IDEA platform, evaluate them through Bloch simulation and reconstruction, and further iteratively refine them using scanner feedback. Results: As test cases, the agentic environment was used to implement and validate a GIRF-based gradient-calibration sequence and reconstruction in approximately 4 hours, and to develop and optimize a rapid 3-second multichannel calibration scan in approximately 12 hours of researcher-guided iteration.

eess.SP↗

FESTiVE: Self-calibrated Spatial-temporal Gradient Characterization for Non-cartesian Imaging on High Performance Systems

Gradient imperfections disrupt the encoding benefits of long-readout imaging applications on high-performance systems. Currently, external field monitoring hardware provides the only reliable solution for general spatial-temporal gradient characterization. We present FESTiVE, a data-driven alternative to higher-order field monitoring. FESTiVE leverages parallel imaging to both implicitly model and explicitly recover field imperfections. Using a fast k-t mapping calibration scan, FESTiVE formulates a time-varying GRAPPA problem which maps k-space data corrupted by a time-varying gradient imperfection against a clean reference. This mapping is represented compactly with an implicit neural representation, from which the spatial-temporal fields are recovered in image space using coil sensitivities. In phantom, FESTiVE produces comparable field measurements to a Skope field camera across multiple non-cartesian 2D acquisition strategies and gradient specifications. In vivo, FESTiVE achieves state-of-the-art image quality for a high-performance diffusion spiral protocol on the head-only MAGNUS 3T, where higher-order phase imperfections are significant. At 7T, on the head-only Siemens TerraX system, FESTiVE enables 300μm spiral imaging where conventional field camera-based approaches fall below probe dephasing limits. In conclusion, FESTiVE enables robust high-resolution non-cartesian imaging on high-performance gradients, characterizing gradient imperfections using parallel imaging rather than field monitoring hardware.

eess.SP↗

Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTI

High-performance head-only gradient systems can substantially reduce echo spacing (ESP) in echo-planar imaging (EPI), but the resulting encoding speed is typically used to shorten readouts and reduce distortion. Here, we instead leverage the increased echo budget to enable denser k-space sampling and higher simultaneous-multislice (SMS) acceleration in SMS-EPI and SMS-EPTI. Fast k-space traversal with denser ky-kz sampling is achieved using peripheral nerve stimulation (PNS)-optimized gradient waveforms, while high-quality reconstruction is obtained using field-correcting GRAPPA (FCG). The resulting ESPs on MAGNUS 3T and Impulse 7T are approximately half those of high-performance whole-body systems, enabling approximately 2-fold higher multiband (MB) acceleration. This facilitates high-quality 2.5-mm isotropic whole-brain resting-state fMRI at 7T with MB28 and a repetition time (TR) of 123 ms.

eess.SP↗

High-Temporal-Resolution Motion Correction in Magnetic Resonance Fingerprinting Using a Quantitative Scout and Compact Spiral Navigators

Motion correction in magnetic resonance fingerprinting (MRF) helps preserve the accuracy of quantitative maps; however, existing approaches provide motion updates only every 7-8 seconds. We propose a navigation framework that integrates compact k-space navigators throughout the MRF acquisition, enabling sub-second motion estimation at minimal sequence overhead. A 3D spiral-projection MRF sequence was augmented with three orthogonal spiral navigators inserted every 0.5 seconds, enabling motion estimation by comparing navigator signals with quantitative scout (Q-Scout) data, i.e., motion-free low-resolution k-space with matching contrast evolution. The Q-Scout is obtained via a rapid calibration during the dummy preparation period, incurring no additional scan time. Motion estimation is formulated as dictionary matching in a discriminant subspace with optimization refinement. The method was evaluated in simulation and in vivo for 1 mm isotropic brain 3D MRF at 3 T. Across 35 motion-corrupted acquisitions with motion-free references available, the proposed motion correction reduced MRF reconstruction normalized root-mean-square error (NRMSE) by 7.1% and increased the structural similarity index measure (SSIM) by 0.085. Motion estimates aligned with 8 second temporal-rate image-based navigation (mean absolute difference of 0.15 mm and 0.23 degrees), while the proposed method provided higher temporal resolution and improved motion correction. The proposed framework enables robust motion navigation in MRF at 0.5 second temporal resolution with minimal sequence overhead. By using contrast-consistent modeling and efficient inference, it improves the reliability of quantitative MRI under rapid, unpredictable motion.

eess.SP↗

Distortion-Corrected Diffusion MRI Using Rotated-View EPI and Joint Field-Map/Image Estimation with Gaussian Primitives

Echo Planar Imaging (EPI) is the standard acquisition technique for diffusion and functional neuroimaging, enabling rapid imaging but suffering from geometric distortions caused by B0 field inhomogeneities. Existing correction methods first reconstruct distorted images using parallel imaging, then estimate the B0 field and correct the distortion in the image domain. In this sequential process, reconstruction artifacts at high acceleration factors and low SNR at high diffusion b-values degrade B0 estimation and limit the overall correction quality. We propose a physics-informed framework that jointly estimates the B0 field and distortion-free image directly from k-space data, without depending on an intermediate parallel-imaging reconstruction for the correction. The image and the B0 field are each represented as a superposition of Gaussian primitives embedded within an MRI physics forward model. The explicit, continuous parameterization captures both smooth regions and tissue boundaries and supports rotated-view EPI acquisitions without interpolation. The diffusion-weighted image is modeled as real and non-negative, with the image phase absorbed into a per-shot phase factor. Rotated views distribute distortions across multiple phase-encoding orientations, improving point spread function isotropy and providing stronger constraints for B0 estimation. On in vivo brain diffusion EPI, the proposed method attains the closest brain-boundary agreement with a distortion-free structural reference, with the largest improvement over sequential methods at high b-value and high acceleration. Extensive visual comparisons further show improved detail fidelity and noise suppression.

eess.IV↗

Motion-Robust Deep Reconstruction for Free-Breathing Cardiac Cine MRI

Conventional cardiac cine MRI relies on breath-hold Cartesian acquisitions, which are vulnerable to motion artifacts and can be uncomfortable or infeasible, particularly for pediatric and other noncompliant patients who cannot reliably hold their breath. Free-breathing radial acquisitions can alleviate these limitations, but robust reconstruction at high acceleration remains challenging due to prominent streak artifacts. To address these limitations, we propose Cine-DL, a clinically oriented framework that couples targeted k-space preprocessing with fast, model-based deep reconstruction. In this pipeline, raw free-breathing radial data undergo retrospective cardiac binning and respiratory gating to resolve cardiac phases and discard motion-corrupted spokes. We then introduce Streak Optimized Coil Compression (SOC), which explicitly preserves cardiac signals while suppressing peripheral interference that typically drives the streak artifacts. The resulting 2D+t cine series is reconstructed with an unrolled network that alternates a ResNet proximal operator with physics-based data consistency updates solved via conjugate gradient. We further employ a memory-efficient training strategy that reduces peak memory usage. We evaluate Cine-DL on free-breathing volunteer data against established baselines (k-t SENSE and iGRASP) and demonstrate clinical translation via hospital deployment on newly acquired patient data. Our experiments show that Cine-DL consistently improves quantitative metrics and visual fidelity, supporting a practical route toward routine, time-sensitive clinical adoption of free-breathing cine MRI.

eess.IV↗

Fast Reconstruction of Motion-Corrupted Data with Mobile-GRAPPA: Motion and dB0 Inhomogeneity Correction Leveraging Efficient GRAPPA

Advanced motion navigations now enable rapid tracking of subject motion and dB0-induced phase, but accurately incorporating this high-temporal-resolution information into SENSE (Aligned-SENSE) is often computationally prohibitive. We propose "Mobile-GRAPPA", a k-space "cleaning" approach that uses local GRAPPA operators to remove motion and dB0 related corruption so that the resulting data can be reconstructed with standard SENSE. We efficiently train a family of k-space-position-specific Mobile-GRAPPA kernels via a lightweight multilayer perceptron (MLP) and apply them across k-space to generate clean data. In experiments on highly motion-corrupted 1-mm whole-brain GRE (Tacq = 10 min; 1,620 motion/dB0 trackings) and EPTI (Tacq = 2 min; 544 trackings), Mobile-GRAPPA enabled accurate reconstruction with negligible time penalty, whereas full Aligned-SENSE was impractical (reconstruction times > 10 h for GRE and > 10 days for EPTI). These results show that Mobile-GRAPPA incorporates detailed motion and dB0 tracking into SENSE with minimal computational overhead, enabling fast, high-quality reconstructions of challenging data.

eess.SP↗

Fast Voxelwise SNR Estimation for Iterative MRI Reconstructions

Purpose: To develop a fast, general-purpose framework for voxelwise noise characterization in linear and nonlinear iterative MRI reconstructions, recovering the image-domain noise variance from which SNR, $g$-factor, and related image-quality metrics are derived. The framework addresses both the intractability of closed-form formulas beyond Cartesian sampling and the long runtime of Pseudo Multiple Replica (PMR) methods. Methods: We propose PICO (Probing Image-space COvariance), an estimator that operates in the image domain by probing the image-domain noise covariance operator -- or, for nonlinear compressed-sensing reconstructions, the Jacobian of the converged solution -- with random probe images. Complex random-phase probes are shown theoretically and empirically to minimize estimator variance compared with Gaussian or real-valued alternatives. PICO was validated against analytical benchmarks and high-replica PMR references using retrospective Cartesian knee data ($R=2$), prospective non-Cartesian spiral brain phantom data ($R=2,3,4$), and compressed-sensing knee reconstructions ($R=2$). Results: In Cartesian experiments, PICO accurately reproduced analytical SENSE $g$-factor maps. In non-Cartesian spiral imaging ($R=2$), it achieved 1% estimation error in 64 s compared with 462 s for PMR (approximately 7.2x speedup), with the efficiency advantage persisting at higher acceleration. For nonlinear compressed sensing, the Jacobian-based estimator produced noise maps consistent with PMR while converging faster (52 s vs. 95 s; approximately 1.8x speedup). Conclusion: PICO provides a computationally efficient alternative to PMR for voxelwise noise and $g$-factor estimation across generalized iterative MRI reconstructions. By reusing existing reconstruction primitives, it enables voxelwise noise maps to be produced as a routine by-product of the reconstruction pipeline.

eess.SP↗

Fully 3D Unrolled Magnetic Resonance Fingerprinting Reconstruction via Staged Pretraining and Implicit Gridding

Magnetic Resonance Fingerprinting (MRF) enables fast quantitative imaging, yet reconstructing high-resolution 3D data remains computationally demanding. Non-Cartesian reconstructions require repeated non-uniform FFTs, and the commonly used Locally Low Rank (LLR) prior adds computational overhead and becomes insufficient at high accelerations. Learned 3D priors could address these limitations, but training them at scale is challenging due to memory and runtime demands. We propose SPUR-iG, a fully 3D deep unrolled subspace reconstruction framework that integrates efficient data consistency with a progressive training strategy. Data consistency leverages implicit GROG, which grids non-Cartesian data onto a Cartesian grid with an implicitly learned kernel, enabling FFT-based updates with minimal artifacts. Training proceeds in three stages: (1) pretraining a denoiser with extensive data augmentation, (2) greedy per-iteration unrolled training, and (3) final fine-tuning with gradient checkpointing. Together, these stages make large-scale 3D unrolled learning feasible within a reasonable compute budget. On a large in vivo dataset with retrospective undersampling, SPUR-iG improves subspace coefficient maps quality and quantitative accuracy at 1-mm isotropic resolution compared with LLR and a hybrid 2D/3D unrolled baseline. Whole-brain reconstructions complete in under 15-seconds, with up to $\times$111 speedup for 2-minute acquisitions. Notably, $T_1$ maps with our method from 30-second scans achieve accuracy on par with or exceeding LLR reconstructions from 2-minute scans. Overall, the framework improves both accuracy and speed in large-scale 3D MRF reconstruction, enabling efficient and reliable accelerated quantitative imaging.

eess.IV↗

OPTIKS: Optimized Gradient Properties Through Timing in K-Space

A customizable method (OPTIKS) for designing fast trajectory-constrained gradient waveforms with optimized time domain properties was developed. Given a specified multidimensional k-space trajectory, the method optimizes traversal speed (and therefore timing) with position along the trajectory. OPTIKS facilitates optimization of objectives dependent on the time domain gradient waveform and the arc-length domain k-space speed. OPTIKS is applied to design waveforms which limit peripheral nerve stimulation (PNS), minimize mechanical resonance excitation, and reduce acoustic noise. A variety of trajectory examples are presented including spirals, circular echo-planar-imaging, and rosettes. Design performance is evaluated based on duration, standardized PNS models, field measurements, gradient coil back-EMF measurements, and calibrated acoustic measurements. We show reductions in back-EMF of up to 94% and field oscillations up to 91.1%, acoustic noise decreases of up to 9.22 dB, and with efficient use of PNS models speed increases of up to 11.4%. The design method implementation is made available as an open source Python package through GitHub.

eess.SY↗

A dynamic shim approach for correcting eddy current effects in diffusion-prepared MRI acquisition using a multi-coil AC/DC shim-array

Purpose: We developed a dynamic B0 shimming approach using a 46-channel AC/DC shim array to correct phase errors caused by eddy currents from diffusion-encoding gradients in diffusion-prepared MRI, enabling high b-value imaging without the SNR loss from the use of magnitude stabilizer. Methods: A 46-channel AC/DC shim array and corresponding amplifier system were built. Spin echo prescans with and without diffusion preparation were then used to rapidly measure eddy current induced phase differences. These phase maps were used as targets in an optimization framework to compute compensatory shim currents for multi-shot 3D diffusion-prepared acquisitions. Results: The proposed method allows flexible use of the AC/DC shim array to correct undesirable eddy current effects in diffusion-prepared MRI. Phantom and in vivo experiments demonstrate whole-brain, cardiac-gated, multi-shot 3D diffusion-prepared imaging without the use of magnitude stabilizers. The approach enables preservation of full SNR while achieving reliable diffusion encoding at b-values up to 2000 s/mm2. Conclusions: This work demonstrates a new strategy for applying an AC/DC shim array to compensate for eddy current induced phase errors in diffusion-prepared MRI. By eliminating the need for magnitude stabilizer, it enables efficient high-quality diffusion imaging with full signal sensitivity retained.

physics.med-ph↗

Accelerating MRI with Longitudinally-informed Latent Posterior Sampling

Purpose: To accelerate MRI acquisition by incorporating the previous scans of a subject during reconstruction. Although longitudinal imaging constitutes much of clinical MRI, leveraging previous scans is challenging due to the complex relationship between scan sessions, potentially involving substantial anatomical or pathological changes, and the lack of open-access datasets with both longitudinal pairs and raw k-space needed for training deep learning-based reconstruction models. Methods: We propose a diffusion-model-based reconstruction framework that eliminates the need for longitudinally paired training data. During training, we treat all scan timepoints as samples from the same distribution, therefore requiring only standalone images. At inference, our framework integrates a subject's prior scan in magnitude DICOM format, which is readily available in clinical workflows, to guide reconstruction of the follow-up. To support future development, we introduce an open-access clinical dataset containing multi-session pairs including prior DICOMs and follow-up k-space. Results: Our method consistently outperforms both longitudinal and non-longitudinal baseline reconstruction methods across various accelerated Cartesian acquisition strategies. In imaging regions highly similar to the prior scan, we observe up to 10\% higher SSIM and 2 dB higher PSNR, without degradation in dissimilar areas. Compared to longitudinal reconstruction baselines, our method demonstrates robustness to varying degrees of anatomical change and misregistration. Conclusion: We demonstrate that prior scans can be effectively integrated with state-of-the-art diffusion-based reconstruction methods to improve image quality and enable greater scan acceleration, without requiring an extensive longitudinally-paired training dataset.

eess.IV↗

Physics-Informed Implicit Neural Representations for Joint B0 Estimation and Echo Planar Imaging

Echo Planar Imaging (EPI) is widely used for its rapid acquisition but suffers from severe geometric distortions due to B0 inhomogeneities, particularly along the phase encoding direction. Existing methods follow a two-step process: reconstructing blip-up/down EPI images, then estimating B0, which can introduce error accumulation and reduce correction accuracy. This is especially problematic in high B0 regions, where distortions align along the same axis, making them harder to disentangle. In this work, we propose a novel approach that integrates Implicit Neural Representations (INRs) with a physics-informed correction model to jointly estimate B0 inhomogeneities and reconstruct distortion-free images from rotated-view EPI acquisitions. INRs offer a flexible, continuous representation that inherently captures complex spatial variations without requiring predefined grid-based field maps. By leveraging this property, our method dynamically adapts to subject-specific B0 variations and improves robustness across different imaging conditions. Experimental results on 180 slices of brain images from three subjects demonstrate that our approach outperforms traditional methods in terms of reconstruction quality and field estimation accuracy.

eess.IV↗

Enhancing Diffusion-Weighted Images (DWI) for Diffusion MRI: Is it Enough without Non-Diffusion-Weighted B=0 Reference?

Diffusion MRI (dMRI) is essential for studying brain microstructure, but high-resolution imaging remains challenging due to the inherent trade-offs between acquisition time and signal-to-noise ratio (SNR). Conventional methods often optimize only the diffusion-weighted images (DWIs) without considering their relationship with the non-diffusion-weighted (b=0) reference images. However, calculating diffusion metrics, such as the apparent diffusion coefficient (ADC) and diffusion tensor with its derived metrics like fractional anisotropy (FA) and mean diffusivity (MD), relies on the ratio between each DWI and the b=0 image, which is crucial for clinical observation and diagnostics. In this study, we demonstrate that solely enhancing DWIs using a conventional pixel-wise mean squared error (MSE) loss is insufficient, as the error in ratio between generated DWIs and b=0 diverges. We propose a novel ratio loss, defined as the MSE loss between the predicted and ground-truth log of DWI/b=0 ratios. Our results show that incorporating the ratio loss significantly improves the convergence of this ratio error, achieving lower ratio MSE and slightly enhancing the peak signal-to-noise ratio (PSNR) of generated DWIs. This leads to improved dMRI super-resolution and better preservation of b=0 ratio-based features for the derivation of diffusion metrics.

eess.IV↗

An Efficient Algorithm for Spatial-Spectral Partial Volume Compartment Mapping with Applications to Multicomponent Diffusion and Relaxation MRI

We introduce a new algorithm to solve a regularized spatial-spectral image estimation problem. Our approach is based on the linearized alternating directions method of multipliers (LADMM), which is a variation of the popular ADMM algorithm. Although LADMM has existed for some time, it has not been very widely used in the computational imaging literature. This is in part because there are many possible ways of mapping LADMM to a specific optimization problem, and it is nontrivial to find a computationally efficient implementation out of the many competing alternatives. We believe that our proposed implementation represents the first application of LADMM to the type of optimization problem considered in this work (involving a linear-mixture forward model, spatial regularization, and nonnegativity constraints). We evaluate our algorithm in a variety of multiparametric MRI partial volume mapping scenarios (diffusion-relaxation, relaxation-relaxation, relaxometry, and fingerprinting), where we consistently observe substantial ($\sim$3$\times$-50$\times$) speed improvements. We expect this to reduce barriers to using spatially-regularized partial volume compartment mapping methods. Further, the considerable improvements we observed also suggest the potential value of considering LADMM for a broader set of computational imaging problems.

eess.SP↗

ACE-Net: AutofoCus-Enhanced Convolutional Network for Field Imperfection Estimation with application to high b-value spiral Diffusion MRI

Spatiotemporal magnetic field variations from B0-inhomogeneity and diffusion-encoding-induced eddy-currents can be detrimental to rapid image-encoding schemes such as spiral, EPI and 3D-cones, resulting in undesirable image artifacts. In this work, a data driven approach for automatic estimation of these field imperfections is developed by combining autofocus metrics with deep learning, and by leveraging a compact basis representation of the expected field imperfections. The method was applied to single-shot spiral diffusion MRI at high b-values where accurate estimation of B0 and eddy were obtained, resulting in high quality image reconstruction without need for additional external calibrations.

physics.med-ph↗

Data and Physics driven Deep Learning Models for Fast MRI Reconstruction: Fundamentals and Methodologies

Magnetic Resonance Imaging (MRI) is a pivotal clinical diagnostic tool, yet its extended scanning times often compromise patient comfort and image quality, especially in volumetric, temporal and quantitative scans. This review elucidates recent advances in MRI acceleration via data and physics-driven models, leveraging techniques from algorithm unrolling models, enhancement-based methods, and plug-and-play models to the emerging full spectrum of generative model-based methods. We also explore the synergistic integration of data models with physics-based insights, encompassing the advancements in multi-coil hardware accelerations like parallel imaging and simultaneous multi-slice imaging, and the optimization of sampling patterns. We then focus on domain-specific challenges and opportunities, including image redundancy exploitation, image integrity, evaluation metrics, data heterogeneity, and model generalization. This work also discusses potential solutions and future research directions, with an emphasis on the role of data harmonization and federated learning for further improving the general applicability and performance of these methods in MRI reconstruction.

eess.SP↗

Compartment-specific estimation of T2 and T2* with diffusion-PEPTIDE MRI

We present a microstructure imaging technique for estimating compartment-specific T2 and T2* simultaneously in the human brain. Microstructure imaging with diffusion MRI (dMRI) has enabled the modelling of intra-neurite and extra-neurite diffusion signals separately allowing for the estimation of compartment-specific tissue properties. These compartment-specific properties have been widely used in clinical studies. However, conventional dMRI cannot disentangle differences in relaxations between tissue compartments, causing biased estimates of diffusion measures which also change with TE. To solve the problem, combined relaxometry-diffusion imaging methods have been developed in recent years, providing compartmental T2-diffusion or T2*-diffusion imaging respectively, but not T2 and T2* together. As they provide complementary information, a technique that can estimate both jointly with diffusion is appealing to neuroimaging studies. The aim of this work is to develop a method to map compartmental T2-T2*-diffusion simultaneously. Using an advanced MRI acquisition called diffusion-PEPTIDE, a novel microstructure model is proposed and a multi-step fitting method is developed to estimate parameters of interest. We demonstrate for the first time that compartmental T2, T2* can be estimated simultaneously from in vivo data. we further show the accuracy and precision of parameter estimation with simulation.

physics.med-ph↗