Search arXivSearch

arXiv subjects

L. Conti

Publications and source records attributed to L. Conti.

At least 19 recordsLinked to original sources

Microchannel plate detector development for ultraviolet astronomy

Observational data from the UV wavelength range is crucial to solve several astrophysical puzzles. Consequently, there are a number of upcoming UV missions from CubeSats up to the future flagship Habitable Worlds Observatory. Besides novel instrument concepts and improved coatings, advanced detectors are key for the success of these missions. The microchannel plate (MCP) detector technology offers a unique asset in the UV: the combination of single-photon counting and visible-blindness. The UV hardware group at the Institut f\"ur Astronomie und Astrophysik T\"ubingen (IAAT) develops a versatile MCP detector system that addresses the complete UV band. While a sealed-tube design is limited to wavelengths above 118\,nm, an open-face variant also covers the whole far- and extreme-UV. Both use the same readout: a coplanar cross-strip anode and FPGA-based electronics. In this contribution, we report on the status of the detector development, present the latest characterization results, and give an outlook on the mission prospects.

astro-ph.IM

Progress towards a microchannel plate detector with AlGaN photocathode and cross-strip anode for ultraviolet astronomy

Microchannel plates (MCPs) were the driving detector technology for ultraviolet (UV) astronomy over many years, and still today MCP-based detectors are the baseline for several planned UV instruments. The development of advanced MCP detectors is ongoing and pursues the major goals of maximizing sensitivity, resolution, and lifetime, while at the same time decreasing weight, volume, and power consumption. Development efforts for an MCP-based detector system for the UV are running at IAAT at the University of T\"ubingen. In this publication, we present our latest results towards coating aluminum gallium nitride (AlGaN) photocathodes directly on MCPs, to improve quantum detection efficiency in the far- and extreme-UV. Furthermore, we report on the implementation of a non-iterative centroiding algorithm for our coplanar cross-strip anode directly in an FPGA.

astro-ph.IM

EUSO-SPB1 Mission and Science

The Extreme Universe Space Observatory on a Super Pressure Balloon 1 (EUSO-SPB1) was launched in 2017 April from Wanaka, New Zealand. The plan of this mission of opportunity on a NASA super pressure balloon test flight was to circle the southern hemisphere. The primary scientific goal was to make the first observations of ultra-high-energy cosmic-ray extensive air showers (EASs) by looking down on the atmosphere with an ultraviolet (UV) fluorescence telescope from suborbital altitude (33~km). After 12~days and 4~hours aloft, the flight was terminated prematurely in the Pacific Ocean. Before the flight, the instrument was tested extensively in the West Desert of Utah, USA, with UV point sources and lasers. The test results indicated that the instrument had sensitivity to EASs of approximately 3 EeV. Simulations of the telescope system, telescope on time, and realized flight trajectory predicted an observation of about 1 event assuming clear sky conditions. The effects of high clouds were estimated to reduce this value by approximately a factor of 2. A manual search and a machine-learning-based search did not find any EAS signals in these data. Here we review the EUSO-SPB1 instrument and flight and the EAS search.

astro-ph.IM

Developments and results in the context of the JEM-EUSO program obtained with the ESAF Simulation and Analysis Framework

JEM--EUSO is an international program for the development of space-based Ultra-High Energy Cosmic Ray observatories. The program consists of a series of missions which are either under development or in the data analysis phase. All instruments are based on a wide-field-of-view telescope, which operates in the near-UV range, designed to detect the fluorescence light emitted by extensive air showers in the atmosphere. We describe the simulation software ESAFin the framework of the JEM--EUSO program and explain the physical assumptions used. We present here the implementation of the JEM--EUSO, POEMMA, K--EUSO, TUS, Mini--EUSO, EUSO--SPB1 and EUSO--TA configurations in ESAF. For the first time ESAF simulation outputs are compared with experimental data.

astro-ph.IM

An Experiment Exploring Gravitational Effects on CP Violation

We suggest a new experiment sensitive to a possible difference between the amount of CP violation as measured on the surface of the Earth and in a lower gravity environment. Our proposed experiment is model independent and could yield a $5\sigma$ measurement within tens of days, indicating a dependence of the level of CP violation in the neutral kaon system on the local gravitational potential.

hep-ph

Status of the STUDIO UV balloon mission and platform

Stratospheric balloons offer accessible and affordable platforms for observations in atmosphere-constrained wavelength ranges. At the same time, they can serve as an effective step for technology demonstration towards future space applications of instruments and other hardware. The Stratospheric UV Demonstrator of an Imaging Observatory (STUDIO) is a balloon-borne platform and mission carrying an imaging micro-channel plate (MCP) detector on a 0.5 m aperture telescope. STUDIO is currently planned to fly during the summer turnaround conditions over Esrange, Sweden, in the 2022 season. For details on the ultraviolet (UV) detector, see the contribution of Conti et al. to this symposium. The scientific goal of the mission is to survey for variable hot compact stars and flaring M-dwarf stars within the galactic plane. At the same time, the mission acts as a demonstrator for a versatile and scalable astronomical balloon platform as well as for the aforementioned MCP instrument. The gondola is designed to allow the use of different instruments or telescopes. Furthermore, it is designed to serve for several, also longer, flights, which are envisioned under the European Stratospheric Balloon Observatory (ESBO) initiative. In this paper, we present the design and current status of manufacturing and testing of the STUDIO platform. We furthermore present the current plans for the flight and observations from Esrange.

astro-ph.IM

First observations of speed of light tracks by a fluorescence detector looking down on the atmosphere

EUSO-Balloon is a pathfinder mission for the Extreme Universe Space Observatory onboard the Japanese Experiment Module (JEM-EUSO). It was launched on the moonless night of the 25$^{th}$ of August 2014 from Timmins, Canada. The flight ended successfully after maintaining the target altitude of 38 km for five hours. One part of the mission was a 2.5 hour underflight using a helicopter equipped with three UV light sources (LED, xenon flasher and laser) to perform an inflight calibration and examine the detectors capability to measure tracks moving at the speed of light. We describe the helicopter laser system and details of the underflight as well as how the laser tracks were recorded and found in the data. These are the first recorded laser tracks measured from a fluorescence detector looking down on the atmosphere. Finally, we present a first reconstruction of the direction of the laser tracks relative to the detector.

astro-ph.IM

A standard siren measurement of the Hubble constant from GW170817 without the electromagnetic counterpart

We perform a statistical standard siren analysis of GW170817. Our analysis does not utilize knowledge of NGC 4993 as the unique host galaxy of the optical counterpart to GW170817. Instead, we consider each galaxy within the GW170817 localization region as a potential host; combining the redshift from each galaxy with the distance estimate from GW170817 provides an estimate of the Hubble constant, $H_0$. We then combine the $H_0$ values from all the galaxies to provide a final measurement of $H_0$. We explore the dependence of our results on the thresholds by which galaxies are included in our sample, as well as the impact of weighting the galaxies by stellar mass and star-formation rate. Considering all galaxies brighter than $0.01 L^\star_B$ as equally likely to host a BNS merger, we find $H_0= 76^{+48}_{-23}$ km s$^{-1}$ Mpc$^{-1}$ (maximum a posteriori and 68.3% highest density posterior interval; assuming a flat $H_0$ prior in the range $\left[ 10, 220 \right]$ km s$^{-1}$ Mpc$^{-1}$). Restricting only to galaxies brighter than $0.626 L^\star_B$ tightens the measurement to $H_0= 77^{+37}_{-18}$ km s$^{-1}$ Mpc$^{-1}$. We show that weighting the host galaxies by stellar mass or star-formation rate provides entirely consistent results with potentially tighter constraints. While these statistical estimates are inferior to the value from the counterpart standard siren measurement utilizing NGC 4993 as the unique host, $H_0=76^{+19}_{-13}$ km s$^{-1}$ Mpc$^{-1}$ (determined from the same publicly available data), our analysis is a proof-of-principle demonstration of the statistical approach first proposed by Bernard Schutz over 30 years ago.

astro-ph.CO

Calibration of Advanced Virgo and Reconstruction of the Gravitational Wave Signal h(t) during the Observing Run O2

In August 2017, Advanced Virgo joined Advanced LIGO for the end of the O2 run, leading to the first gravitational waves detections with the three-detector network. This paper describes the Advanced Virgo calibration and the gravitational wave strain h(t) reconstruction during O2. The methods are the same as the ones developed for the initial Virgo detector and have already been described in previous publications, this paper summarizes the differences and emphasis is put on estimating systematic uncertainties. Three versions of the h(t) signal have been computed for the Virgo O2 run, an online version and two post-run reprocessed versions with improved detector calibration and reconstruction algorithm. A photon calibrator has been used to establish the sign of h(t) and to make an independent partial cross-check of the systematic uncertainties. The uncertainties reached for the latest h(t) version are 5.1% in amplitude, 40 mrad in phase and 20 microseconds in timing.

gr-qc

IGEC2: A 17-month search for gravitational wave bursts in 2005-2007

We present here the results of a 515 days long run of the IGEC2 observatory, consisting of the four resonant mass detectors ALLEGRO, AURIGA, EXPLORER and NAUTILUS. The reported results are related to the fourfold observation time from Nov. 6 2005 until Apr. 14 2007, when Allegro ceased its operation. This period overlapped with the first long term observations performed by the LIGO interferometric detectors. The IGEC observations aim at the identification of gravitational wave candidates with high confidence, keeping the false alarm rate at the level of 1 per century, and high duty cycle, namely 57% with all four sites and 94% with at least three sites in simultaneous observation. The network data analysis is based on time coincidence searches over at least three detectors: the four 3-fold searches and the 4-fold one are combined in a logical OR. We exchanged data with the usual blind procedure, by applying a unique confidential time offset to the events in each set of data. The accidental background was investigated by performing sets of 10^8 coincidence analyses per each detector configuration on off-source data, obtained by shifting the time series of each detector. The thresholds of the five searches were tuned so as to control the overall false alarm rate to 1/century. When the confidential time shifts was disclosed, no gravitational wave candidate was found in the on-source data. As an additional output of this search, we make available to other observatories the list of triple coincidence found below search thresholds, corresponding to a false alarm rate of 1/month.

gr-qc

Nonequilibrium steady state fluctuations in actively cooled resonators

We analyze heat and work fluctuations in the gravitational wave detector AURIGA, modeled as a macroscopic electromechanical oscillator in contact with a thermostat and cooled by an active feedback system. The oscillator is driven to a steady state by the feedback cooling, equivalent to a viscous force. The experimentally measured fluctuations are in agreement with our theoretical analysis based on a stochastically driven Langevin system. The asymmetry of the fluctuations of the absorbed heat characterizes the oscillator's nonequilibrium steady state and reveals the extent to which a feedback cooled system departs from equilibrium in a statistical mechanics perspective.

cond-mat.stat-mech

Feedback cooling of the normal modes of a massive electromechanical system to submillikelvin temperature

We apply a feedback cooling technique to simultaneously cool the three electromechanical normal modes of the ton-scale resonant-bar gravitational wave detector AURIGA. The measuring system is based on a dc Superconducting Quantum Interference Device (SQUID) amplifier, and the feedback cooling is applied electronically to the input circuit of the SQUID. Starting from a bath temperature of 4.2 K, we achieve a minimum temperature of 0.17 mK for the coolest normal mode. The same technique, implemented in a dedicated experiment at subkelvin bath temperature and with a quantum limited SQUID, could allow to approach the quantum ground state of a kilogram-scale mechanical resonator.

quant-ph

Upper limits on gravitational waves emission in association with the Dec 27 2004 giant flare of SGR1806-20

At the time when the giant flare of SGR1806-20 occurred, the AURIGA "bar" gw detector was on the air with a noise performance close to stationary gaussian. This allows to set relevant upper limits, at a number of frequencies in the vicinities of 900 Hz, on the amplitude of the damped gw wave trains, which, according to current models, could have been emitted, due to the excitation of normal modes of the star associated with the peak in X-rays luminosity.

astro-ph

3-mode detection for widening the bandwidth of resonant gravitational wave detectors

We have implemented a novel scheme of signal readout for resonant gravitational wave detectors. For the first time, a capacitive resonant transducer has been matched to the signal amplifier by means of a tuned high Q electrical resonator. The resulting 3-mode detection scheme widens significantly the bandwidth of the detector. We present here the results achieved by this signal readout equipped with a two-stage SQUID amplifier. Once installed on the AURIGA detector, the one-sided spectral sensitivity obtained with the detector operated at 4.5 K is better than 10^-20 Hz^-1/2 over 110 Hz and in good agreement with the expectations.

gr-qc