Search arXivSearch

arXiv subjects

M. Dhellot

Publications and source records attributed to M. Dhellot.

5 recordsLinked to original sources

Beam-test evaluation of pre-production Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment as part of the Phase-II upgrade for the High Luminosity-Large Hadron Collider (HL-LHC). It will mitigate pile-up effects in the forward region, and measure per bunch luminosity. The design of HGTD is based on Low Gain Avalanche Detector (LGAD) sensors. This paper presents the results of beam-test campaigns conducted at CERN and DESY in 2023 and 2024 on single LGADs from HGTD pre-production test structures, before and after neutron irradiation up to fluences of $2.5 \times 10^{15}~\mathrm{n_{eq}/cm^2}$. The tested LGADs can meet HGTD requirements in terms of charge collection, time resolution, and hit efficiency, even under HL-LHC end-of-life conditions, supporting their deployment in the final detector.

physics.ins-det

Thermal Cycling Reliability of Hybrid Pixel Sensor Modules for The ATLAS High Granularity Timing Detector

The reliability of bump connection structures has become a critical aspect of future silicon detectors for particle physics. The High Granularity Timing Detector (HGTD) for the ATLAS experiment at the High-Luminosity Large Hadron Collider will require 8032 hybrid pixel sensor modules, composed of two Low Gain Avalanche Diode sensors bump-bonded to two readout ASICs and glued to a passive PCB. The detector will operate at low temperature (-30 degrees Celsius) to mitigate the impact of irradiation. The thermomechanical reliability of flip-chip bump connections in HGTD modules is a critical concern, particularly due to their characteristically lower bump density (pixel pitch dimensions of 1.3 mm by 1.3 mm). This paper elaborates on the challenges arising from this design characteristic. Finite element analysis and experimental testing were employed to investigate failure modes in the flip-chip bump structures under thermal cycling from -45 degrees Celsius to 40 degrees Celsius and to guide the module redesign. The optimized design demonstrates significantly enhanced robustness and is projected to fulfill the full lifetime requirements of the HGTD.

physics.ins-det

First Production of Skipper-CCD Modules for the DAMIC-M Experiment

The DAMIC-M experiment will search for sub-GeV dark matter particles with a large array of silicon skipper charge-coupled devices (CCDs) at the Modane Underground Laboratory (LSM) in France. After five years of development, we recently completed the production of 28 CCD modules at the University of Washington, each consisting of four 9-megapixel skipper CCDs. Material screening and background controls were implemented to meet stringent radio-purity targets, while extensive testing was employed to select science-grade CCDs for the modules and confirm their excellent performance after fabrication. Further testing at LSM will select 26 of these modules (${\sim}$350 g active mass) to be installed and operated in the DAMIC-M detector in early 2026.

physics.ins-det

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_{\chi}$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.

physics.ins-det

The DAMIC-M Experiment: Status and First Results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

hep-ex