Search arXiv⌕ Search

arXiv subjects

Maarten De Vos

Publications and source records attributed to Maarten De Vos.

At least 37 records · Page 2Linked to original sources

Explaining the Model and Feature Dependencies by Decomposition of the Shapley Value

Shapley values have become one of the go-to methods to explain complex models to end-users. They provide a model agnostic post-hoc explanation with foundations in game theory: what is the worth of a player (in machine learning, a feature value) in the objective function (the output of the complex machine learning model). One downside is that they always require outputs of the model when some features are missing. These are usually computed by taking the expectation over the missing features. This however introduces a non-trivial choice: do we condition on the unknown features or not? In this paper we examine this question and claim that they represent two different explanations which are valid for different end-users: one that explains the model and one that explains the model combined with the feature dependencies in the data. We propose a new algorithmic approach to combine both explanations, removing the burden of choice and enhancing the explanatory power of Shapley values, and show that it achieves intuitive results on simple problems. We apply our method to two real-world datasets and discuss the explanations. Finally, we demonstrate how our method is either equivalent or superior to state-to-of-art Shapley value implementations while simultaneously allowing for increased insight into the model-data structure.

cs.LG↗

U-PASS: an Uncertainty-guided deep learning Pipeline for Automated Sleep Staging

As machine learning becomes increasingly prevalent in critical fields such as healthcare, ensuring the safety and reliability of machine learning systems becomes paramount. A key component of reliability is the ability to estimate uncertainty, which enables the identification of areas of high and low confidence and helps to minimize the risk of error. In this study, we propose a machine learning pipeline called U-PASS tailored for clinical applications that incorporates uncertainty estimation at every stage of the process, including data acquisition, training, and model deployment. The training process is divided into a supervised pre-training step and a semi-supervised finetuning step. We apply our uncertainty-guided deep learning pipeline to the challenging problem of sleep staging and demonstrate that it systematically improves performance at every stage. By optimizing the training dataset, actively seeking informative samples, and deferring the most uncertain samples to an expert, we achieve an expert-level accuracy of 85% on a challenging clinical dataset of elderly sleep apnea patients, representing a significant improvement over the baseline accuracy of 75%. U-PASS represents a promising approach to incorporating uncertainty estimation into machine learning pipelines, thereby improving their reliability and unlocking their potential in clinical settings.

eess.SP↗

CoRe-Sleep: A Multimodal Fusion Framework for Time Series Robust to Imperfect Modalities

Sleep abnormalities can have severe health consequences. Automated sleep staging, i.e. labelling the sequence of sleep stages from the patient's physiological recordings, could simplify the diagnostic process. Previous work on automated sleep staging has achieved great results, mainly relying on the EEG signal. However, often multiple sources of information are available beyond EEG. This can be particularly beneficial when the EEG recordings are noisy or even missing completely. In this paper, we propose CoRe-Sleep, a Coordinated Representation multimodal fusion network that is particularly focused on improving the robustness of signal analysis on imperfect data. We demonstrate how appropriately handling multimodal information can be the key to achieving such robustness. CoRe-Sleep tolerates noisy or missing modalities segments, allowing training on incomplete data. Additionally, it shows state-of-the-art performance when testing on both multimodal and unimodal data using a single model on SHHS-1, the largest publicly available study that includes sleep stage labels. The results indicate that training the model on multimodal data does positively influence performance when tested on unimodal data. This work aims at bridging the gap between automated analysis tools and their clinical utility.

eess.SP↗

Automated Movement Detection with Dirichlet Process Mixture Models and Electromyography

Numerous sleep disorders are characterised by movement during sleep, these include rapid-eye movement sleep behaviour disorder (RBD) and periodic limb movement disorder. The process of diagnosing movement related sleep disorders requires laborious and time-consuming visual analysis of sleep recordings. This process involves sleep clinicians visually inspecting electromyogram (EMG) signals to identify abnormal movements. The distribution of characteristics that represent movement can be diverse and varied, ranging from brief moments of tensing to violent outbursts. This study proposes a framework for automated limb-movement detection by fusing data from two EMG sensors (from the left and right limb) through a Dirichlet process mixture model. Several features are extracted from 10 second mini-epochs, where each mini-epoch has been classified as 'leg-movement' or 'no leg-movement' based on annotations of movement from sleep clinicians. The distributions of the features from each category can be estimated accurately using Gaussian mixture models with the Dirichlet process as a prior. The available dataset includes 36 participants that have all been diagnosed with RBD. The performance of this framework was evaluated by a 10-fold cross validation scheme (participant independent). The study was compared to a random forest model and outperformed it with a mean accuracy, sensitivity, and specificity of 94\%, 48\%, and 95\%, respectively. These results demonstrate the ability of this framework to automate the detection of limb movement for the potential application of assisting clinical diagnosis and decision-making.

q-bio.QM↗

SleepTransformer: Automatic Sleep Staging with Interpretability and Uncertainty Quantification

Background: Black-box skepticism is one of the main hindrances impeding deep-learning-based automatic sleep scoring from being used in clinical environments. Methods: Towards interpretability, this work proposes a sequence-to-sequence sleep-staging model, namely SleepTransformer. It is based on the transformer backbone and offers interpretability of the model's decisions at both the epoch and sequence level. We further propose a simple yet efficient method to quantify uncertainty in the model's decisions. The method, which is based on entropy, can serve as a metric for deferring low-confidence epochs to a human expert for further inspection. Results: Making sense of the transformer's self-attention scores for interpretability, at the epoch level, the attention scores are encoded as a heat map to highlight sleep-relevant features captured from the input EEG signal. At the sequence level, the attention scores are visualized as the influence of different neighboring epochs in an input sequence (i.e. the context) to recognition of a target epoch, mimicking the way manual scoring is done by human experts. Conclusion: Additionally, we demonstrate that SleepTransformer performs on par with existing methods on two databases of different sizes. Significance: Equipped with interpretability and the ability of uncertainty quantification, SleepTransformer holds promise for being integrated into clinical settings.

cs.LG↗

Feature matching as improved transfer learning technique for wearable EEG

Objective: With the rapid rise of wearable sleep monitoring devices with non-conventional electrode configurations, there is a need for automated algorithms that can perform sleep staging on configurations with small amounts of labeled data. Transfer learning has the ability to adapt neural network weights from a source modality (e.g. standard electrode configuration) to a new target modality (e.g. non-conventional electrode configuration). Methods: We propose feature matching, a new transfer learning strategy as an alternative to the commonly used finetuning approach. This method consists of training a model with larger amounts of data from the source modality and few paired samples of source and target modality. For those paired samples, the model extracts features of the target modality, matching these to the features from the corresponding samples of the source modality. Results: We compare feature matching to finetuning for three different target domains, with two different neural network architectures, and with varying amounts of training data. Particularly on small cohorts (i.e. 2 - 5 labeled recordings in the non-conventional recording setting), feature matching systematically outperforms finetuning with mean relative differences in accuracy ranging from 0.4% to 4.7% for the different scenarios and datasets. Conclusion: Our findings suggest that feature matching outperforms finetuning as a transfer learning approach, especially in very low data regimes. Significance: As such, we conclude that feature matching is a promising new method for wearable sleep staging with novel devices.

eess.SP↗

Interpretable Deep Learning for the Remote Characterisation of Ambulation in Multiple Sclerosis using Smartphones

The emergence of digital technologies such as smartphones in healthcare applications have demonstrated the possibility of developing rich, continuous, and objective measures of multiple sclerosis (MS) disability that can be administered remotely and out-of-clinic. In this work, deep convolutional neural networks (DCNN) applied to smartphone inertial sensor data were shown to better distinguish healthy from MS participant ambulation, compared to standard Support Vector Machine (SVM) feature-based methodologies. To overcome the typical limitations associated with remotely generated health data, such as low subject numbers, sparsity, and heterogeneous data, a transfer learning (TL) model from similar large open-source datasets was proposed. Our TL framework utilised the ambulatory information learned on Human Activity Recognition (HAR) tasks collected from similar smartphone-based sensor data. A lack of transparency of "black-box" deep networks remains one of the largest stumbling blocks to the wider acceptance of deep learning for clinical applications. Ensuing work therefore aimed to visualise DCNN decisions attributed by relevance heatmaps using Layer-Wise Relevance Propagation (LRP). Through the LRP framework, the patterns captured from smartphone-based inertial sensor data that were reflective of those who are healthy versus persons with MS (PwMS) could begin to be established and understood. Interpretations suggested that cadence-based measures, gait speed, and ambulation-related signal perturbations were distinct characteristics that distinguished MS disability from healthy participants. Robust and interpretable outcomes, generated from high-frequency out-of-clinic assessments, could greatly augment the current in-clinic assessment picture for PwMS, to inform better disease management techniques, and enable the development of better therapeutic interventions.

cs.LG↗

XSleepNet: Multi-View Sequential Model for Automatic Sleep Staging

Automating sleep staging is vital to scale up sleep assessment and diagnosis to serve millions experiencing sleep deprivation and disorders and enable longitudinal sleep monitoring in home environments. Learning from raw polysomnography signals and their derived time-frequency image representations has been prevalent. However, learning from multi-view inputs (e.g., both the raw signals and the time-frequency images) for sleep staging is difficult and not well understood. This work proposes a sequence-to-sequence sleep staging model, XSleepNet, that is capable of learning a joint representation from both raw signals and time-frequency images. Since different views may generalize or overfit at different rates, the proposed network is trained such that the learning pace on each view is adapted based on their generalization/overfitting behavior. In simple terms, the learning on a particular view is speeded up when it is generalizing well and slowed down when it is overfitting. View-specific generalization/overfitting measures are computed on-the-fly during the training course and used to derive weights to blend the gradients from different views. As a result, the network is able to retain the representation power of different views in the joint features which represent the underlying distribution better than those learned by each individual view alone. Furthermore, the XSleepNet architecture is principally designed to gain robustness to the amount of training data and to increase the complementarity between the input views. Experimental results on five databases of different sizes show that XSleepNet consistently outperforms the single-view baselines and the multi-view baseline with a simple fusion strategy. Finally, XSleepNet also outperforms prior sleep staging methods and improves previous state-of-the-art results on the experimental databases.

eess.SP↗

Estimation of Continuous Blood Pressure from PPG via a Federated Learning Approach

Ischemic heart disease is the highest cause of mortality globally each year. This not only puts a massive strain on the lives of those affected but also on the public healthcare systems. To understand the dynamics of the healthy and unhealthy heart doctors commonly use electrocardiogram (ECG) and blood pressure (BP) readings. These methods are often quite invasive, in particular when continuous arterial blood pressure (ABP) readings are taken and not to mention very costly. Using machine learning methods we seek to develop a framework that is capable of inferring ABP from a single optical photoplethysmogram (PPG) sensor alone. We train our framework across distributed models and data sources to mimic a large-scale distributed collaborative learning experiment that could be implemented across low-cost wearables. Our time series-to-time series generative adversarial network (T2TGAN) is capable of high-quality continuous ABP generation from a PPG signal with a mean error of 2.54 mmHg and a standard deviation of 23.7 mmHg when estimating mean arterial pressure on a previously unseen, noisy, independent dataset. To our knowledge, this framework is the first example of a GAN capable of continuous ABP generation from an input PPG signal that also uses a federated learning methodology.

cs.LG↗

Change Point Detection in Time Series Data using Autoencoders with a Time-Invariant Representation

Change point detection (CPD) aims to locate abrupt property changes in time series data. Recent CPD methods demonstrated the potential of using deep learning techniques, but often lack the ability to identify more subtle changes in the autocorrelation statistics of the signal and suffer from a high false alarm rate. To address these issues, we employ an autoencoder-based methodology with a novel loss function, through which the used autoencoders learn a partially time-invariant representation that is tailored for CPD. The result is a flexible method that allows the user to indicate whether change points should be sought in the time domain, frequency domain or both. Detectable change points include abrupt changes in the slope, mean, variance, autocorrelation function and frequency spectrum. We demonstrate that our proposed method is consistently highly competitive or superior to baseline methods on diverse simulated and real-life benchmark data sets. Finally, we mitigate the issue of false detection alarms through the use of a postprocessing procedure that combines a matched filter and a newly proposed change point score. We show that this combination drastically improves the performance of our method as well as all baseline methods.

cs.LG↗

Improving GANs for Speech Enhancement

Generative adversarial networks (GAN) have recently been shown to be efficient for speech enhancement. However, most, if not all, existing speech enhancement GANs (SEGAN) make use of a single generator to perform one-stage enhancement mapping. In this work, we propose to use multiple generators that are chained to perform multi-stage enhancement mapping, which gradually refines the noisy input signals in a stage-wise fashion. Furthermore, we study two scenarios: (1) the generators share their parameters and (2) the generators' parameters are independent. The former constrains the generators to learn a common mapping that is iteratively applied at all enhancement stages and results in a small model footprint. On the contrary, the latter allows the generators to flexibly learn different enhancement mappings at different stages of the network at the cost of an increased model size. We demonstrate that the proposed multi-stage enhancement approach outperforms the one-stage SEGAN baseline, where the independent generators lead to more favorable results than the tied generators. The source code is available at http://github.com/pquochuy/idsegan.

cs.LG↗

Towards More Accurate Automatic Sleep Staging via Deep Transfer Learning

Background: Despite recent significant progress in the development of automatic sleep staging methods, building a good model still remains a big challenge for sleep studies with a small cohort due to the data-variability and data-inefficiency issues. This work presents a deep transfer learning approach to overcome these issues and enable transferring knowledge from a large dataset to a small cohort for automatic sleep staging. Methods: We start from a generic end-to-end deep learning framework for sequence-to-sequence sleep staging and derive two networks as the means for transfer learning. The networks are first trained in the source domain (i.e. the large database). The pretrained networks are then finetuned in the target domain (i.e. the small cohort) to complete knowledge transfer. We employ the Montreal Archive of Sleep Studies (MASS) database consisting of 200 subjects as the source domain and study deep transfer learning on three different target domains: the Sleep Cassette subset and the Sleep Telemetry subset of the Sleep-EDF Expanded database, and the Surrey-cEEGrid database. The target domains are purposely adopted to cover different degrees of data mismatch to the source domains. Results: Our experimental results show significant performance improvement on automatic sleep staging on the target domains achieved with the proposed deep transfer learning approach. Conclusions: These results suggest the efficacy of the proposed approach in addressing the above-mentioned data-variability and data-inefficiency issues. Significance: As a consequence, it would enable one to improve the quality of automatic sleep staging models when the amount of data is relatively small. The source code and the pretrained models are available at http://github.com/pquochuy/sleep_transfer_learning.

cs.LG↗

Monitoring Depression in Bipolar Disorder using Circadian Measures from Smartphone Accelerometers

Current management of bipolar disorder relies on self-reported questionnaires and interviews with clinicians. The development of objective measures of deteriorating mood may also allow for early interventions to take place to avoid transitions into depressive states. The objective of this study was to use acceleration data recorded from smartphones to predict levels of depression in a population of participants diagnosed with bipolar disorder. Data were collected from 52 participants, with a mean of 37 weeks of acceleration data with a corresponding depression score recorded per participant. Time varying hidden Markov models were used to extract weekly features of activity, sleep and circadian rhythms. Personalised regression achieved mean absolute errors of 1.00(0.57) from a possible scale of 0 to 27 and was able to classify depression with an accuracy of 0.84(0.16). The results demonstrate features derived from smartphone accelerometers are able to provide objective markers of depression. Low barriers for uptake exist due to the widespread use of smartphones, with personalised models able to account for differences in the behaviour of individuals and provide accurate predictions of depression.

eess.SP↗

Personalized Automatic Sleep Staging with Single-Night Data: a Pilot Study with KL-Divergence Regularization

Brain waves vary between people. An obvious way to improve automatic sleep staging for longitudinal sleep monitoring is personalization of algorithms based on individual characteristics extracted from the first night of data. As a single night is a very small amount of data to train a sleep staging model, we propose a Kullback-Leibler (KL) divergence regularized transfer learning approach to address this problem. We employ the pretrained SeqSleepNet (i.e. the subject independent model) as a starting point and finetune it with the single-night personalization data to derive the personalized model. This is done by adding the KL divergence between the output of the subject independent model and the output of the personalized model to the loss function during finetuning. In effect, KL-divergence regularization prevents the personalized model from overfitting to the single-night data and straying too far away from the subject independent model. Experimental results on the Sleep-EDF Expanded database with 75 subjects show that sleep staging personalization with a single-night data is possible with help of the proposed KL-divergence regularization. On average, we achieve a personalized sleep staging accuracy of 79.6%, a Cohen's kappa of 0.706, a macro F1-score of 73.0%, a sensitivity of 71.8%, and a specificity of 94.2%. We find both that the approach is robust against overfitting and that it improves the accuracy by 4.5 percentage points compared to non-personalization and 2.2 percentage points compared to personalization without regularization.

cs.LG↗

Screening for REM Sleep Behaviour Disorder with Minimal Sensors

Rapid-Eye-Movement (REM) sleep behaviour disorder (RBD) is an early predictor of Parkinson's disease, dementia with Lewy bodies, and multiple system atrophy. This study investigates a minimal set of sensors to achieve effective screening for RBD in the population, integrating automated sleep staging (three state) followed by RBD detection without the need for cumbersome electroencephalogram (EEG) sensors. Polysomnography signals from 50 participants with RBD and 50 age-matched healthy controls were used to evaluate this study. Three stage sleep classification was achieved using a Random Forest (RF) classifier and features derived from a combination of cost-effective and easy to use sensors, namely electrocardiogram (ECG), electrooculogram (EOG), and electromyogram (EMG) channels. Subsequently, RBD detection was achieved using established and new metrics derived from ECG and EMG metrics. The EOG and EMG combination provided the best minimalist fully automated performance, achieving $0.57\pm0.19$ kappa (3 stage) for sleep staging and an RBD detection accuracy of $0.90\pm0.11$, (sensitivity, and specificity $0.88\pm0.13$, and $0.92\pm0.098$). A single ECG sensor allowed three state sleep staging with $0.28\pm0.06$ kappa and RBD detection accuracy of $0.62\pm0.10$. This study demonstrated the feasibility of using signals from a single EOG and EMG sensor to detect RBD using fully-automated techniques. This study proposes a cost-effective, practical, and simple RBD identification support tool using only two sensors (EMG and EOG), ideal for screening purposes.

q-bio.QM↗

Spatio-Temporal Attention Pooling for Audio Scene Classification

Acoustic scenes are rich and redundant in their content. In this work, we present a spatio-temporal attention pooling layer coupled with a convolutional recurrent neural network to learn from patterns that are discriminative while suppressing those that are irrelevant for acoustic scene classification. The convolutional layers in this network learn invariant features from time-frequency input. The bidirectional recurrent layers are then able to encode the temporal dynamics of the resulting convolutional features. Afterwards, a two-dimensional attention mask is formed via the outer product of the spatial and temporal attention vectors learned from two designated attention layers to weigh and pool the recurrent output into a final feature vector for classification. The network is trained with between-class examples generated from between-class data augmentation. Experiments demonstrate that the proposed method not only outperforms a strong convolutional neural network baseline but also sets new state-of-the-art performance on the LITIS Rouen dataset.

cs.SD↗

Deep Transfer Learning for Single-Channel Automatic Sleep Staging with Channel Mismatch

Many sleep studies suffer from the problem of insufficient data to fully utilize deep neural networks as different labs use different recordings set ups, leading to the need of training automated algorithms on rather small databases, whereas large annotated databases are around but cannot be directly included into these studies for data compensation due to channel mismatch. This work presents a deep transfer learning approach to overcome the channel mismatch problem and transfer knowledge from a large dataset to a small cohort to study automatic sleep staging with single-channel input. We employ the state-of-the-art SeqSleepNet and train the network in the source domain, i.e. the large dataset. Afterwards, the pretrained network is finetuned in the target domain, i.e. the small cohort, to complete knowledge transfer. We study two transfer learning scenarios with slight and heavy channel mismatch between the source and target domains. We also investigate whether, and if so, how finetuning entirely or partially the pretrained network would affect the performance of sleep staging on the target domain. Using the Montreal Archive of Sleep Studies (MASS) database consisting of 200 subjects as the source domain and the Sleep-EDF Expanded database consisting of 20 subjects as the target domain in this study, our experimental results show significant performance improvement on sleep staging achieved with the proposed deep transfer learning approach. Furthermore, these results also reveal the essential of finetuning the feature-learning parts of the pretrained network to be able to bypass the channel mismatch problem.

cs.LG↗

NeoGuard: a public, online learning platform for neonatal seizures

Seizures occur in the neonatal period more frequently than other periods of life and usually denote the presence of serious brain dysfunction. The gold standard for detecting seizures is based on visual inspection of continuous electroencephalogram (cEEG) complemented by video analysis, performed by an expert clinical neurophysiologist. Previous studies have reported varying degree of agreement between expert EEG readers, with kappa coefficients ranging from 0.4 to 0.85, calling into question the validity of visual scoring. This variability in visual scoring of neonatal seizures may be due to factors such as reader expertise and the nature of expressed patterns. One of the possible reasons for low inter-rater agreement is the absence of any benchmark for the EEG readers to be able to compare their opinions. One way to develop this is to use a shared multi-center neonatal seizure database and use the inputs from multiple experts. This will also improve the teaching of trainees, and help to avoid potential bias from a single expert's opinion. In this paper, we introduce and explain the NeoGuard public learning platform that can be used by trainees, tutors, and expert EEG readers who are interested to test their knowledge and learn from neonatal EEG-polygraphic segments scored by several expert EEG readers. For this platform, 1919 clinically relevant segments, totaling 280h, recorded from 71 term neonates in two centers, including a wide variety of seizures and artifacts were used. These segments were scored by 4 EEG readers from three different centers. Users of this platform can score an arbitrary number of segments and then test their scoring with the experts' opinions. The kappa and joint probability of agreement, is then shown as inter-rater agreement metrics between the user and each of the experts. The platform is publicly available at the NeoGuard website (www.neoguard.net).

q-bio.NC↗