Search arXivSearch

arXiv subjects

Marc Ferrari

Publications and source records attributed to Marc Ferrari.

At least 19 recordsLinked to original sources

Continuing to Advance European High Contrast Imaging Research and Development towards HWO and LIFE

The European Research and Development for Space based High Contrast Imaging II Workshop, held at MPIA in May 2025, advanced Europe strategic coordination in support of future exoplanet imaging missions such as the Habitable Worlds Observatory and the Large Interferometer for Exoplanets mission. Building on the first 2024 workshop, this meeting defined concrete priorities across eight technical areas, including wavefront sensing, coronagraphs, post processing, nulling interferometry, deformable mirrors, detectors, and telescope design. Discussions emphasized Europe strengths in adaptive optics, ground-based facilities, and interferometry, while identifying key gaps, particularly the need for a dedicated European vacuum testbed for high contrast imaging. The community highlighted near infrared or UV coronagraphy as a promising domain for European leadership and called for joint development of advanced data reduction algorithms, detectors, and cross-mission coordination with HWO and LIFE. The workshop outcomes establish a collaborative roadmap to strengthen Europe technological readiness, foster agency partnerships, and ensure its continued leadership in the next generation of space-based exoplanet exploration.

astro-ph.IM

Design of a custom wideband camera for MISTRAL imager-spectrograph

MISTRAL is a visible and near infrared imager and spectrograph working with the $1.93m$ telescope at L'Observatoire de Haute-Provence. The goal of the present project is to design and build one custom lens covering the entire working band 370-1000 nm with an enhanced throughput and resolution. The proposed design has the focal length of 100 mm with f/#=2 and consists of 5 lenses with 2 aspheres. It is capable to work in spectroscopy or direct imaging mode with the spectral resolving power up to R590-1675 or energy concentration of 84% within 1 pixel. The throughput varies from 79 to 98% in the main band of 400-1000 nm with a commercial AR coating and could be yet improved with a custom one. We also demonstrate that with this image quality can be maintained in a <10% margin with practically reachable tolerances.

astro-ph.IM

High-contrast imager for complex aperture telescopes (HiCAT): 8. Dark zone demonstration with simultaneous closed-loop low-order wavefront sensing and control

We present recent laboratory results demonstrating high-contrast coronagraphy for the future space-based large IR/Optical/Ultraviolet telescope recommended by the Decadal Survey. The High-contrast Imager for Complex Aperture Telescopes (HiCAT) testbed aims to implement a system-level hardware demonstration for segmented aperture coronagraphs with wavefront control. The telescope hardware simulator employs a segmented deformable mirror with 37 hexagonal segments that can be controlled in piston, tip, and tilt. In addition, two continuous deformable mirrors are used for high-order wavefront sensing and control. The low-order sensing subsystem includes a dedicated tip-tilt stage, a coronagraphic target acquisition camera, and a Zernike wavefront sensor that is used to measure and correct low-order aberration drifts. We explore the performance of a segmented aperture coronagraph both in static operations (limited by natural drifts and instabilities) and in dynamic operations (in the presence of artificial wavefront drifts added to the deformable mirrors), and discuss the estimation and control strategies used to reach and maintain the dark-zone contrast using our low-order wavefront sensing and control. We summarize experimental results that quantify the performance of the testbed in terms of contrast, inner/outer working angle and bandpass, and analyze limiting factors.

astro-ph.IM

High-contrast imager for complex aperture telescopes (HiCAT): 11. System-level demonstration of the Apodized Pupil Lyot Coronagraph with a segmented aperture in air

We present the final results of the Apodized Pupil Lyot Coronagraph (APLC) on the High-contrast imager for Complex Aperture Telescopes (HiCAT) testbed, under NASA's Strategic Astrophysics Technology program. The HiCAT testbed was developed over the past decade to enable a system-level demonstration of coronagraphy for exoplanet direct imaging with the future Habitable Wolds Observatory. HiCAT includes an active, segmented telescope simulator, a coronagraph, and metrology systems (Low-order and Mid-Order Zernike Wavefront Sensors, and Phase Retrieval camera). These results correspond to an off-axis (un-obscured) configuration, as was envisioned in the 2020 Decadal Survey Recommendations. Narrowband and broadband dark holes are generated using two continuous deformable mirrors (DM) to control high order wavefront aberrations, and low-order drifts can be further stabilized using the LOWFS loop. The APLC apodizers, manufactured using carbon nanotubes, were optimized for broadband performance and include the calibrated geometric aperture. HiCAT is, to this date, the only testbed facility able to demonstrate high-contrast coronagraphy with a truly segmented aperture, as is required for the Habitable World Observatory, albeit limited to ambient conditions. Results presented here include $6\times 10^{-8}$ (90% CI) contrast in 9% bandpass in a 360 deg dark hole with inner and outer working angles of $4.4 \lambda/D_{pupil}$ and $11 \lambda/D_{pupil}$ . Narrowband contrast (3% bandpass) reaches $2.4\times 10^{-8}$ (90% confidence interval).

astro-ph.IM

Active deployable primary mirrors on CubeSat

The volume available on small satellites restricts the size of optical apertures to a few centimetres, limiting the Ground-Sampling Distance (GSD) in the visible to typically 3 m at 500 km. We present in this paper the latest development of a laboratory demonstrator of a segmented deployable telescope that will triple the achievable ground resolution and improve photometric capability of CubeSat imagers. Each mirror segment is folded for launch and unfolds in space. We demonstrate through laboratory validation very high deployment repeatability of the mirrors <{\pm}5 {\mu}m. To enable diffraction-limited imaging, segments are controlled in piston, tip, and tilt. This is achieved by an initial coarse alignment of the mirrors followed by a fine phasing step. Finally, we investigate the impact of the thermal environment on high-order wavefront error and the conceptual design of a deployable secondary fitting inside 1U.

astro-ph.IM

3D printing for astronomical mirrors

3D printing, also called additive manufacturing, offers a new vision for optical fabrication in term of achievable optical quality and reduction of weight and cost. In this paper we describe two different ways to use this technique in the fabrication process. The first method makes use of 3D printing in the fabrication of warping harnesses for stress polishing, and we apply that to the fabrication of the WFIRST coronagraph off axis parabolas. The second method considers a proof of concept for 3D printing of lightweight X-Ray mirrors, targeting the next generation of X-rays telescopes. Stress polishing is well suited for the fabrication of the high quality off axis parabolas required by the coronagraph to image exoplanets.. Here we describe a new design of warping harness which can generate astigmatism and coma with only one actuator. The idea is to incorporate 3D printing in the manufacturing of the warping harness. The method depicted in this paper demonstrates that we reach the tight precision required at the mirrors surface. Moreover the error introduced by the warping harness fabricated by 3D printing does not impact the final error budget. Concerning the proof of concept project, we investigate 3D printing towards lightweight X-ray mirrors. We present the surface metrology of test samples fabricated by stereo lithography (SLA) and Selective Laser Sintering (SLS) with different materials. The lightweighting of the samples is composed of a series of arches. By complementing 3D printing with finite element analysis topology optimization we can simulate a specific optimum shape for the given input parameters and external boundary conditions. The next set of prototypes is designed taking to account the calculation of topology optimisation.

astro-ph.IM

Superpolished OAPs for WFIRST CGI

Exoplanet imaging requires super polished off-axis parabolas (OAP) with the utmost surface quality. In this paper we describe an innovative manufacturing process combining 3D printing and stress polishing, to create a warping harness capable of producing any off axis parabola profile with a single actuator. The warping harness is manufactured by 3D printing. This method will be applied to the production of the WFIRST coronagraph's off axis parabolas. The evolution of the warping harness design is presented, starting from a ring warping harness generating astigmatism, to an innovative thickness distribution harness optimised to generate an off axis parabola shape. Several design options are available for the prototyping phase, with their advantages and disadvantages which will be discussed.

astro-ph.IM

Space Project for Astrophysical and Cosmological Exploration (SPACE), an ESA stand-alone mission and a possible contribution to the Origins Space Telescope

We propose a new mission called Space Project for Astrophysical and Cosmological Exploration (SPACE) as part on the ESA long term planning Voyage 2050 programme. SPACE will study galaxy evolution at the earliest times, with the key goals of charting the formation of the heavy elements, measuring the evolution of the galaxy luminosity function, tracing the build-up of stellar mass in galaxies over cosmic time, and finding the first super-massive black holes (SMBHs) to form. The mission will exploit a unique region of the parameter space, between the narrow ultra-deep surveys with HST and JWST, and shallow wide-field surveys such as Roman Space Telescope and EUCLID, and should yield by far the largest sample of any current or planned mission of very high redshift galaxies at z > 10 which are sufficiently bright for detailed follow-up spectroscopy. Crucially, we propose a wide-field spectroscopic near-IR + mid-IR capability which will greatly enhance our understanding of the first galaxies by detecting and identifying a statistical sample of the first galaxies and the first SMBH, and to chart the metal enrichment history of galaxies in the early Universe - potentially finding signatures of the very first stars to form from metal-free primordial gas. The wide-field and wavelength range of SPACE will also provide us a unique opportunity to study star formation by performing a wide survey of the Milky Way in the near-IR + mid-IR. This science project can be enabled either by a stand-alone ESA-led M mission or by an instrument for an L mission (with ESA and/or NASA, JAXA and other international space agencies) with a wide-field (sub-)millimetre capability at wavelength > 500 microns.

astro-ph.IM

Stress mirror polishing for future large lightweight mirrors: design using shape optimization

This study proposes a new way to manufacture large lightweight aspherics for space telescopes using Stress Mirror Polishing (SMP). This technique is well known to allow reaching high quality optical surfaces in a minimum time period, thanks to a spherical full-size polishing tool. To obtain the correct surface' aspheric shape, it is necessary to define precisely the thickness distribution of the mirror to be deformed, according to the manufacturing parameters. We first introduce active optics and Stress Mirror Polishing techniques, and then, we describe the process to obtain the appropriate thickness mirror distribution allowing to generate the required aspheric shape during polishing phase. Shape optimization procedure using PYTHON programing and NASTRAN optimization solver using Finite Element Model (FEM) is developed and discussed in order to assist this process. The main result of this paper is the ability of the shape optimization process to support SMP technique to generate a peculiar aspherical shape from a spherical optical surface thanks to a thickness distribution reshaping. This paper is primarily focused on a theoretical framework with numerical simulations as the first step before the manufacturing of a demonstrator. This two-steps approach was successfully used for previous projects.

astro-ph.IM

Key Technologies for the Wide Field Infrared Survey Telescope Coronagraph Instrument

The Wide Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument (CGI) is a high-contrast imager and integral field spectrograph that will enable the study of exoplanets and circumstellar disks at visible wavelengths. Ground-based high-contrast instrumentation has fundamentally limited performance at small working angles, even under optimistic assumptions for 30m-class telescopes. There is a strong scientific driver for better performance, particularly at visible wavelengths. Future flagship mission concepts aim to image Earth analogues with visible light flux ratios of more than 10^10. CGI is a critical intermediate step toward that goal, with a predicted 10^8-9 flux ratio capability in the visible. CGI achieves this through improvements over current ground and space systems in several areas: (i) Hardware: space-qualified (TRL9) deformable mirrors, detectors, and coronagraphs, (ii) Algorithms: wavefront sensing and control; post-processing of integral field spectrograph, polarimetric, and extended object data, and (iii) Validation of telescope and instrument models at high accuracy and precision. This white paper, submitted to the 2018 NAS Exoplanet Science Strategy call, describes the status of key CGI technologies and presents ways in which performance is likely to evolve as the CGI design matures.

astro-ph.IM

Design and modelling of spectrographs with holographic gratings on freeform surfaces

In the present paper we demonstrate the approach of using a holographic grating on a freeform surface for advanced spectrographs design. We discuss the surface and groove pattern description used for ray-tracing. Moreover, we present a general procedure of diffraction efficiency calculation, which accounts for the change of hologram recording and operation conditions across the surface. The primary application of this approach is the optical design of the POLLUX spectropolarimeter for the LUVOR mission project where a freeform holographic grating operates simultaneously as a cross-disperser and a camera with high resolution and high dispersion. The medium ultraviolet channel design of POLLUX is considered in detail as an example. Its resolving power reaches [126,000-133,000] in the region of 118.5-195 nm. Also, we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 4000 in the region 350-550 nm and remains stable along the slit.

astro-ph.IM

James Webb Space Telescope Optical Simulation Testbed V: Wide-field phase retrieval assessment

The James Webb Space Telescope (JWST) Optical Simulation Testbed (JOST) is a hardware simulator for wavefront sensing and control designed to produce JWST-like images. A model of the JWST three mirror anas- tigmat is realized with three lenses in the form of a Cooke triplet, which provides JWST-like optical quality over a field equivalent to a NIRCam module. An Iris AO hexagonally segmented mirror stands in for the JWST primary. This setup successfully produces images extremely similar to expected JWST in-flight point spread functions (PSFs), and NIRCam images from cryotesting, in terms of the PSF morphology and sampling relative to the diffraction limit. The segmentation of the primary mirror into subapertures introduces complexity into wavefront sensing and control (WFS&C) of large space based telescopes like JWST. JOST provides a platform for independent analysis of WFS&C scenarios for both commissioning and maintenance activities on such ob- servatories. We present an update of the current status of the testbed including both single field and wide-field alignment results. We assess the optical quality of JOST over a wide field of view to inform the future imple- mentation of different wavefront sensing algorithms including the currently implemented Linearized Algorithm for Phase Diversity (LAPD). JOST complements other work at the Makidon Laboratory at the Space Telescope Science Institute, including the High-contrast imager for Complex Aperture Telescopes (HiCAT) testbed, that investigates coronagraphy for segmented aperture telescopes. Beyond JWST we intend to use JOST for WFS&C studies for future large segmented space telescopes such as LUVOIR.

astro-ph.IM

Curved detectors developments and characterization: application to astronomical instruments

Many astronomical optical systems have the disadvantage of generating curved focal planes requiring flattening optical elements to project the corrected image on flat detectors. The use of these designs in combination with a classical flat sensor implies an overall degradation of throughput and system performances to obtain the proper corrected image. With the recent development of curved sensor this can be avoided. This new technology has been gathering more and more attention from a very broad community, as the potential applications are multiple: from low-cost commercial to high impact scientific systems, to mass-market and on board cameras, defense and security, and astronomical community. We describe here the first concave curved CMOS detector developed within a collaboration between CNRS- LAM and CEA-LETI. This fully-functional detector 20 Mpix (CMOSIS CMV20000) has been curved down to a radius of Rc = 150 mm over a size of 24x32 mm^2 . We present here the methodology adopted for its characterization and describe in detail all the results obtained. We also discuss the main components of noise, such as the readout noise, the fixed pattern noise and the dark current. Finally we provide a comparison with the flat version of the same sensor in order to establish the impact of the curving process on the main characteristics of the sensor.

astro-ph.IM

Design of optical systems with toroidal curved detectors

We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured re-imaging three-mirror anastigmat as an example (f'=960 mm, F/5.3, FoV 4x4 degrees). By assuming that the image is focused on a toroidal detector surface and perform re-optimization, it becomes possible to obtain a notable gain in the image quality - up to 40 % in terms of the spot RMS radius. Through analytic computations and finite-element analysis, we demonstrate that this toroidal shape can be obtained by bending of a thinned detector in a relatively simple setup.

astro-ph.IM

POLLUX: a UV spectropolarimeter for the LUVOIR space telescope project

The present paper describes the current baseline optical design of POLLUX, a high-resolution spectropolarimeter for the future LUVOIR mission. The instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in both spectropolarimetric and pure spectroscopic modes. The working range is split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near (195-390 nm) UV. Each of the channels is composed of a polarimeter followed by an echelle spectrograph consisting of a classical off-axis paraboloid collimator, echelle grating with a high grooves frequency and a cross-disperser grating operating also as a camera. The latter component integrates some advanced technologies: it is a blazed grating with a complex grooves pattern formed by holographic recording, which is manufactured on a freeform surface. One of the key features underlying the current design is the large spectral length of each order ~6 nm, which allows to record wide spectral lines without any discontinuities. The modelling results show that the optical design will provide the required spectral resolving power higher than R ~ 120,000 over the entire working range for a point source object with angular size of 30 mas. It is also shown that with the 15-m primary mirror of the LUVOIR telescope the instrument will provide an effective collecting area up to 38 569 cm 2. Such a performance will allow to perform a number of groundbreaking scientific observations. Finally, the future work and the technological risks of the design are discussed in details.

astro-ph.IM

Curved detectors for wide field imaging systems: impact on tolerance analysis

In the present paper we consider quantitative estimation of the tolerances widening in optical systems with curved detectors. The gain in image quality allows to loosen the margins for manufacturing and assembling errors. On another hand, the requirements for the detector shape and positioning become more tight. We demonstrate both of the effects on example of two optical designs. The first one is a rotationally-symmetrical lens with focal length of 25 mm, f-ratio of 3.5 and field of view equal to 72$^\circ$, working in the visible domain. The second design is a three-mirror anastigmat telescope with focal length of 250 mm, f-ratio of 2.0 and field of view equal to $4^\circ \times 4^\circ$. In both of the cases use of curved detectors allow to increase the image quality and substantially decrease the requirements for manufacturing precision

astro-ph.IM

Advanced optical designs of curved detectors-based two-mirrors unobscured telescopes

In the present paper we consider a family of unobscured telescope designs with curved detectors. They are based on classical two-mirror schemes -- Ritchey-Chretien, Gregorian and Couder telescopes. It is shown that all the designs provide nearly diffraction limited image quality in the visible domain for $.4^\circ \times .4^\circ$ field of view with the f-number of 7. We also provide a brief ghost analysis and point on special features of the systems with curved detectors. Finally, the detector surface shape obtained in each case is analyzed and its' technological feasibility is demonstrated.

astro-ph.IM

Spectrographs with holographic gratings on freeform surfaces: design approach and application for the LUVOIR mission

In the present paper we demonstrate the approach to use a holographic grating on a freeform surface for advanced spectrographs design. On the example POLLUX spectropolarimeter medium-UV channel we chow that such a grating can operate as a cross-disperser and a camera mirror at the same time. It provides the image quality high enough to reach the spectral resolving power of 126 359-133 106 between 11.5 and 195 nm, which is higher than the requirement. Also we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 2750 for a long slit. It is also shown that the parameters of both the gratings are feasible with the current technologies.

astro-ph.IM