Search arXiv⌕ Search

arXiv subjects

Mathias Unberath

Publications and source records attributed to Mathias Unberath.

132 records · Page 8Linked to original sources

Closing the Calibration Loop: An Inside-out-tracking Paradigm for Augmented Reality in Orthopedic Surgery

In percutaneous orthopedic interventions the surgeon attempts to reduce and fixate fractures in bony structures. The complexity of these interventions arises when the surgeon performs the challenging task of navigating surgical tools percutaneously only under the guidance of 2D interventional X-ray imaging. Moreover, the intra-operatively acquired data is only visualized indirectly on external displays. In this work, we propose a flexible Augmented Reality (AR) paradigm using optical see-through head mounted displays. The key technical contribution of this work includes the marker-less and dynamic tracking concept which closes the calibration loop between patient, C-arm and the surgeon. This calibration is enabled using Simultaneous Localization and Mapping of the environment of the operating theater. In return, the proposed solution provides in situ visualization of pre- and intra-operative 3D medical data directly at the surgical site. We demonstrate pre-clinical evaluation of a prototype system, and report errors for calibration and target registration. Finally, we demonstrate the usefulness of the proposed inside-out tracking system in achieving "bull's eye" view for C-arm-guided punctures. This AR solution provides an intuitive visualization of the anatomy and can simplify the hand-eye coordination for the orthopedic surgeon.

cs.CV↗

On-the-fly Augmented Reality for Orthopaedic Surgery Using a Multi-Modal Fiducial

Fluoroscopic X-ray guidance is a cornerstone for percutaneous orthopaedic surgical procedures. However, two-dimensional observations of the three-dimensional anatomy suffer from the effects of projective simplification. Consequently, many X-ray images from various orientations need to be acquired for the surgeon to accurately assess the spatial relations between the patient's anatomy and the surgical tools. In this paper, we present an on-the-fly surgical support system that provides guidance using augmented reality and can be used in quasi-unprepared operating rooms. The proposed system builds upon a multi-modality marker and simultaneous localization and mapping technique to co-calibrate an optical see-through head mounted display to a C-arm fluoroscopy system. Then, annotations on the 2D X-ray images can be rendered as virtual objects in 3D providing surgical guidance. We quantitatively evaluate the components of the proposed system, and finally, design a feasibility study on a semi-anthropomorphic phantom. The accuracy of our system was comparable to the traditional image-guided technique while substantially reducing the number of acquired X-ray images as well as procedure time. Our promising results encourage further research on the interaction between virtual and real objects, that we believe will directly benefit the proposed method. Further, we would like to explore the capabilities of our on-the-fly augmented reality support system in a larger study directed towards common orthopaedic interventions.

cs.CV↗

Plan in 2D, execute in 3D: An augmented reality solution for cup placement in total hip arthroplasty

Reproducibly achieving proper implant alignment is a critical step in total hip arthroplasty (THA) procedures that has been shown to substantially affect patient outcome. In current practice, correct alignment of the acetabular cup is verified in C-arm X-ray images that are acquired in an anterior-posterior (AP) view. Favorable surgical outcome is, therefore, heavily dependent on the surgeon's experience in understanding the 3D orientation of a hemispheric implant from 2D AP projection images. This work proposes an easy to use intra-operative component planning system based on two C-arm X-ray images that is combined with 3D augmented reality (AR) visualization that simplifies impactor and cup placement according to the planning by providing a real-time RGBD data overlay. We evaluate the feasibility of our system in a user study comprising four orthopedic surgeons at the Johns Hopkins Hospital, and also report errors in translation, anteversion, and abduction as low as 1.98 mm, 1.10 degrees, and 0.53 degrees, respectively. The promising performance of this AR solution shows that deploying this system could eliminate the need for excessive radiation, simplify the intervention, and enable reproducibly accurate placement of acetabular implants.

cs.CV↗

Technical Note: Towards Virtual Monitors for Image Guided Interventions - Real-time Streaming to Optical See-Through Head-Mounted Displays

Purpose: Image guidance is crucial for the success of many interventions. Images are displayed on designated monitors that cannot be positioned optimally due to sterility and spatial constraints. This indirect visualization causes potential occlusion, hinders hand-eye coordination, leads to increased procedure duration and surgeon load. Methods: We propose a virtual monitor system that displays medical images in a mixed reality visualization using optical see-through head-mounted displays. The system streams high-resolution medical images from any modality to the head-mounted display in real-time that are blended with the surgical site. It allows for mixed reality visualization of images in head-, world-, or body-anchored mode and can thus be adapted to specific procedural needs. Results: For typical image sizes, the proposed system exhibits an average end-to-end delay and refresh rate of 214 +- 30 ms and 41:4 +- 32:0 Hz, respectively. Conclusions: The proposed virtual monitor system is capable of real-time mixed reality visualization of medical images. In future, we seek to conduct first pre-clinical studies to quantitatively assess the impact of the system on standard image guided procedures.

cs.OH↗

UI-Net: Interactive Artificial Neural Networks for Iterative Image Segmentation Based on a User Model

For complex segmentation tasks, fully automatic systems are inherently limited in their achievable accuracy for extracting relevant objects. Especially in cases where only few data sets need to be processed for a highly accurate result, semi-automatic segmentation techniques exhibit a clear benefit for the user. One area of application is medical image processing during an intervention for a single patient. We propose a learning-based cooperative segmentation approach which includes the computing entity as well as the user into the task. Our system builds upon a state-of-the-art fully convolutional artificial neural network (FCN) as well as an active user model for training. During the segmentation process, a user of the trained system can iteratively add additional hints in form of pictorial scribbles as seed points into the FCN system to achieve an interactive and precise segmentation result. The segmentation quality of interactive FCNs is evaluated. Iterative FCN approaches can yield superior results compared to networks without the user input channel component, due to a consistent improvement in segmentation quality after each interaction.

cs.CV↗

Seminar Innovation Management - Winter Term 2017

This document contains the results obtained by the Innovation Management Seminar in winter term 2017. In total 11 ideas have been developed by the team. In the document all 11 ideas show improvements for future applications in ophthalmology. The 11 ideas are AR/VR Glasses with Medical Applications, Augmented Reality Eye Surgery, Game Diagnosis, Intelligent Adapting Glasses, MD Facebook, Medical Crowd Segmentation, Personalized 3D Model of the Human Eye, Photoacoustic Contact Lens, Power Supply Smart Contact Lens, VR-Cornea and Head Mount for Fundus Imaging

cs.HC↗