Search arXivSearch

arXiv subjects

Maya Varma

Publications and source records attributed to Maya Varma.

At least 19 recordsLinked to original sources

Gradient-Stable Attention Heads Signal LLM Correctness

Large language models (LLMs) often generate plausible yet incorrect answers, posing risks in safety-critical settings such as medicine. Human evaluation is expensive, and LLM-as-judge approaches risk introducing hidden errors. Recent single-pass white-box methods detect contextual hallucinations using linear probes over model internals, but their generalization to out-of-domain, out-of-task, and training-free settings remains poorly understood. We introduce HeadEntropy, a method that predicts answer correctness by measuring how susceptible each attention head's pattern is to modification under further gradient updates. The key insight is that the trace of the softmax Jacobian is a monotonic function of 2-Renyi entropy, linking attention spread to gradient stability during training, even without the reference annotation. With no training, HeadEntropy reaches 0.736 AUROC, outperforms every training-free baseline in paired comparison and matches a hidden-state probe out-of-domain, at under 1% of inference cost. We evaluate broadly across 5 instruction-tuned LLMs and 5 datasets spanning general knowledge, multi-hop reasoning, mathematical reasoning, claim verification, and medicine. The code is available at https://github.com/StanfordMIMI/HeadEntropy.

cs.LG

Symbal: Detecting Systematic Misalignments in Model-Generated Captions

Multimodal large language models (MLLMs) often introduce errors when generating image captions, resulting in misaligned image-text pairs. Our work focuses on a class of captioning errors that we refer to as systematic misalignments, where a recurring error in MLLM-generated captions is closely associated with the presence of a specific visual feature in the paired image. Given a vision-language dataset with MLLM-generated captions, our aim in this work is to detect such errors, a task we refer to as systematic misalignment detection. As our first key contribution, we present Symbal, which utilizes a structured, dual-stage setup with off-the-shelf foundation models to identify systematic misalignments and summarize results in natural language. As our second key contribution, we introduce SymbalBench, a benchmark designed to evaluate automated methods on our proposed task. SymbalBench consists of 1.7 million image-text pairs from two domains (natural and medical images), organized into 420 vision-language datasets with annotated systematic misalignments. Symbal exhibits strong performance on this benchmark, correctly identifying systematic misalignments in 63.8% of datasets, a nearly 4x improvement over the closest baseline. We supplement our evaluations on SymbalBench with real-world evaluations, showing that (1) Symbal can accurately surface systematic misalignments in captions generated by four MLLMs and (2) Symbal is a powerful tool for auditing off-the-shelf image-caption datasets. Ultimately, our novel task, method, and benchmark can aid users with auditing MLLM-generated captions and identifying critical errors, without requiring access to the underlying MLLM. Code is available at https://github.com/Stanford-AIMI/Symbal.

cs.CV

CheXmix: Unified Generative Pretraining for Vision Language Models in Medical Imaging

Recent medical multimodal foundation models are built as multimodal LLMs (MLLMs) by connecting a CLIP-pretrained vision encoder to an LLM using LLaVA-style finetuning. This two-stage, decoupled approach introduces a projection layer that can distort visual features. This is especially concerning in medical imaging where subtle cues are essential for accurate diagnoses. In contrast, early-fusion generative approaches such as Chameleon eliminate the projection bottleneck by processing image and text tokens within a single unified sequence, enabling joint representation learning that leverages the inductive priors of language models. We present CheXmix, a unified early-fusion generative model trained on a large corpus of chest X-rays paired with radiology reports. We expand on Chameleon's autoregressive framework by introducing a two-stage multimodal generative pretraining strategy that combines the representational strengths of masked autoencoders with MLLMs. The resulting models are highly flexible, supporting both discriminative and generative tasks at both coarse and fine-grained scales. Our approach outperforms well-established generative models across all masking ratios by 6.0% and surpasses CheXagent by 8.6% on AUROC at high image masking ratios on the CheXpert classification task. We further inpaint images over 51.0% better than text-only generative models and outperform CheXagent by 45% on the GREEN metric for radiology report generation. These results demonstrate that CheXmix captures fine-grained information across a broad spectrum of chest X-ray tasks. Our code is at: https://github.com/StanfordMIMI/CheXmix.

cs.CV

A Reasoning-Enabled Vision-Language Foundation Model for Chest X-ray Interpretation

Chest X-rays (CXRs) are among the most frequently performed imaging examinations worldwide, yet rising imaging volumes increase radiologist workload and the risk of diagnostic errors. Although artificial intelligence (AI) systems have shown promise for CXR interpretation, most generate only final predictions, without making explicit how visual evidence is translated into radiographic findings and diagnostic predictions. We present CheXOne, a reasoning-enabled vision-language model for CXR interpretation. CheXOne jointly generates diagnostic predictions and explicit, clinically grounded reasoning traces that connect visual evidence, radiographic findings, and these predictions. The model is trained on 14.7 million instruction and reasoning samples curated from 30 public datasets spanning 36 CXR interpretation tasks, using a two-stage framework that combines instruction tuning with reinforcement learning to improve reasoning quality. We evaluate CheXOne in zero-shot settings across visual question answering, report generation, visual grounding and reasoning assessment, covering 17 evaluation settings. CheXOne outperforms existing medical and general-domain foundation models and achieves strong performance on independent public benchmarks. A clinical reader study demonstrates that CheXOne-drafted reports are comparable to or better than resident-written reports in 55% of cases, while effectively addressing clinical indications and enhancing both report writing and CXR interpretation efficiency. Further analyses involving radiologists reveal that the generated reasoning traces show high clinical factuality and provide causal support for the final predictions, offering a plausible explanation for the performance gains. These results suggest that explicit reasoning can improve model performance, interpretability and clinical utility in AI-assisted CXR interpretation.

cs.CV

Activation Matters: Test-time Activated Negative Labels for OOD Detection with Vision-Language Models

Out-of-distribution (OOD) detection aims to identify samples that deviate from in-distribution (ID). One popular pipeline addresses this by introducing negative labels distant from ID classes and detecting OOD based on their distance to these labels. However, such labels may present poor activation on OOD samples, failing to capture the OOD characteristics. To address this, we propose \underline{T}est-time \underline{A}ctivated \underline{N}egative \underline{L}abels (TANL) by dynamically evaluating activation levels across the corpus dataset and mining candidate labels with high activation responses during the testing process. Specifically, TANL identifies high-confidence test images online and accumulates their assignment probabilities over the corpus to construct a label activation metric. Such a metric leverages historical test samples to adaptively align with the test distribution, enabling the selection of distribution-adaptive activated negative labels. By further exploring the activation information within the current testing batch, we introduce a more fine-grained, batch-adaptive variant. To fully utilize label activation knowledge, we propose an activation-aware score function that emphasizes negative labels with stronger activations, boosting performance and enhancing its robustness to the label number. Our TANL is training-free, test-efficient, and grounded in theoretical justification. Experiments on diverse backbones and wide task settings validate its effectiveness. Notably, on the large-scale ImageNet benchmark, TANL significantly reduces the FPR95 from 17.5\% to 9.8\%. Codes are available at \href{https://github.com/YBZh/OpenOOD-VLM}{YBZh/OpenOOD-VLM}.

cs.CV

Learning Generalizable 3D Medical Image Representations from Mask-Guided Self-Supervision

Foundation models have transformed vision and language by learning general-purpose representations from large-scale unlabeled data, yet 3D medical imaging lacks analogous approaches. Existing self-supervised methods rely on low-level reconstruction or contrastive objectives that fail to capture the anatomical semantics critical for medical image analysis, limiting transfer to downstream tasks. We present MASS (MAsk-guided Self-Supervised learning), which treats in-context segmentation as the pretext task for learning general-purpose medical imaging representations. MASS's key insight is that automatically generated class-agnostic masks provide sufficient structural supervision for learning semantically rich representations. By training on thousands of diverse mask proposals spanning anatomical structures and pathological findings, MASS learns what semantically defines medical structures: the holistic combination of appearance, shape, spatial context, and anatomical relationships. We demonstrate effectiveness across data regimes: from small-scale pretraining on individual datasets (20-200 scans) to large-scale multi-modal pretraining on 5K CT, MRI, and PET volumes, all without annotations. MASS demonstrates: (i) few-shot segmentation on novel structures, (ii) matching full supervision with only 20-40\% labeled data while outperforming self-supervised baselines by over 20 in Dice score in low-data regimes, and (iii) frozen-encoder classification on unseen pathologies that matches full supervised training with thousands of samples. Mask-guided self-supervised pretraining captures broadly generalizable knowledge, opening a path toward 3D medical imaging foundation models without expert annotations. Code is available: https://github.com/Stanford-AIMI/MASS.

cs.CV

Merlin: A Computed Tomography Vision-Language Foundation Model and Dataset

The large volume of abdominal computed tomography (CT) scans coupled with the shortage of radiologists have intensified the need for automated medical image analysis tools. Previous state-of-the-art approaches for automated analysis leverage vision-language models (VLMs) that jointly model images and radiology reports. However, current medical VLMs are generally limited to 2D images and short reports. Here to overcome these shortcomings for abdominal CT interpretation, we introduce Merlin, a 3D VLM that learns from volumetric CT scans, electronic health record data and radiology reports. This approach is enabled by a multistage pretraining framework that does not require additional manual annotations. We trained Merlin using a high-quality clinical dataset of paired CT scans (>6 million images from 15,331 CT scans), diagnosis codes (>1.8 million codes) and radiology reports (>6 million tokens). We comprehensively evaluated Merlin on 6 task types and 752 individual tasks that covered diagnostic, prognostic and quality-related tasks. The non-adapted (off-the-shelf) tasks included zero-shot classification of findings (30 findings), phenotype classification (692 phenotypes) and zero-shot cross-modal retrieval (image-to-findings and image-to-impression). The model-adapted tasks included 5-year chronic disease prediction (6 diseases), radiology report generation and 3D semantic segmentation (20 organs). We validated Merlin at scale, with internal testing on 5,137 CT scans and external testing on 44,098 CT scans from 3 independent sites and 2 public datasets. The results demonstrated high generalization across institutions and anatomies. Merlin outperformed 2D VLMs, CT foundation models and off-the-shelf radiology models. We also release our trained models, code, and dataset, available at: https://github.com/StanfordMIMI/Merlin.

cs.CV

A data- and compute-efficient chest X-ray foundation model beyond aggressive scaling

Foundation models for medical imaging are typically pretrained on increasingly large datasets, following a "scale-at-all-costs" paradigm. However, this strategy faces two critical challenges: large-scale medical datasets often contain substantial redundancy and severe class imbalance that bias representation learning toward over-represented patterns, and indiscriminate training regardless of heterogeneity in data quality incurs considerable computational inefficiency. Here we demonstrate that active, principled data curation during pretraining can serve as a viable, cost-effective alternative to brute-force dataset enlargement. We introduce CheXficient, a chest X-ray (CXR) foundation model that selectively prioritizes informative training samples. CheXficient is pretrained on only 22.7% of 1,235,004 paired CXR images and reports while consuming under 27.3% of the total compute budget, yet achieving comparable or superior performance to its full-data counterpart and other large-scale pretrained models. We assess CheXficient across 20 individual benchmarks spanning 5 task types, including non-adapted off-the-shelf evaluations (zero-shot findings classification and crossmodal retrieval) and adapted downstream tasks (disease prediction, semantic segmentation, and radiology report generation). Further analyses show that CheXficient systematically prioritizes under-represented training samples, improving generalizability on long-tailed or rare conditions. Overall, our work offers practical insights into the data and computation demands for efficient pretraining and downstream adaptation of medical vision-language foundation models.

cs.CV

MedVAL: Toward Expert-Level Medical Text Validation with Language Models

With the growing use of language models (LMs) in clinical environments, there is an immediate need to evaluate the accuracy and safety of LM-generated medical text. Currently, such evaluation relies solely on manual physician review. However, detecting errors in LM-generated text is challenging because 1) manual review is costly and 2) expert-composed reference outputs are often unavailable in real-world settings. While the "LLM-as-a-judge" paradigm offers scalable evaluation, even frontier LMs can miss subtle but clinically significant errors. We propose MedVAL, a novel, self-supervised, data-efficient distillation method that leverages synthetic data to train evaluator LMs to assess whether LM-generated medical outputs are factually consistent with inputs, without requiring physician labels or reference outputs. To evaluate LM performance, we introduce MedVAL-Bench, a dataset of 840 physician-annotated outputs across 6 diverse medical tasks capturing real-world challenges. Across 10 state-of-the-art LMs spanning open-source and proprietary models, MedVAL distillation significantly improves (p < 0.001) alignment with physicians across seen and unseen tasks, increasing average F1 scores from 66% to 83%. Despite strong baseline performance, MedVAL improves the best-performing proprietary LM (GPT-4o) by 8% without training on physician-labeled data, demonstrating a performance statistically non-inferior to a single human expert on a subset annotated by multiple physicians (p < 0.001). To support a scalable, risk-aware pathway towards clinical integration, we open-source: 1) Codebase (https://github.com/StanfordMIMI/MedVAL), 2) MedVAL-Bench (https://huggingface.co/datasets/stanfordmimi/MedVAL-Bench), 3) MedVAL-4B (https://huggingface.co/stanfordmimi/MedVAL-4B). Our benchmark provides evidence of LMs approaching expert-level ability in validating AI-generated medical text.

cs.CL

SMMILE: An Expert-Driven Benchmark for Multimodal Medical In-Context Learning

Multimodal in-context learning (ICL) remains underexplored despite significant potential for domains such as medicine. Clinicians routinely encounter diverse, specialized tasks requiring adaptation from limited examples, such as drawing insights from a few relevant prior cases or considering a constrained set of differential diagnoses. While multimodal large language models (MLLMs) have shown advances in medical visual question answering (VQA), their ability to learn multimodal tasks from context is largely unknown. We introduce SMMILE, the first expert-driven multimodal ICL benchmark for medical tasks. Eleven medical experts curated problems, each including a multimodal query and multimodal in-context examples as task demonstrations. SMMILE encompasses 111 problems (517 question-image-answer triplets) covering 6 medical specialties and 13 imaging modalities. We further introduce SMMILE++, an augmented variant with 1038 permuted problems. A comprehensive evaluation of 15 MLLMs demonstrates that most models exhibit moderate to poor multimodal ICL ability in medical tasks. In open-ended evaluations, ICL contributes only an 8% average improvement over zero-shot on SMMILE and 9.4% on SMMILE++. We observe a susceptibility for irrelevant in-context examples: even a single noisy or irrelevant example can degrade performance by up to 9.5%. Moreover, we observe that MLLMs are affected by a recency bias, where placing the most relevant example last can lead to substantial performance improvements of up to 71%. Our findings highlight critical limitations and biases in current MLLMs when learning multimodal medical tasks from context. SMMILE is available at https://smmile-benchmark.github.io.

cs.LG

RadDiff: Describing Differences in Radiology Image Sets with Natural Language

Understanding how two radiology image sets differ is critical for generating clinical insights and for interpreting medical AI systems. We introduce RadDiff, a multimodal agentic system that performs radiologist-style comparative reasoning to describe clinically meaningful differences between paired radiology studies. RadDiff builds on a proposer-ranker framework from VisDiff, and incorporates four innovations inspired by real diagnostic workflows: (1) medical knowledge injection through domain-adapted vision-language models; (2) multimodal reasoning that integrates images with their clinical reports; (3) iterative hypothesis refinement across multiple reasoning rounds; and (4) targeted visual search that localizes and zooms in on salient regions to capture subtle findings. To evaluate RadDiff, we construct RadDiffBench, a challenging benchmark comprising 57 expert-validated radiology study pairs with ground-truth difference descriptions. On RadDiffBench, RadDiff achieves 47% accuracy, and 50% accuracy when guided by ground-truth reports, significantly outperforming the general-domain VisDiff baseline. We further demonstrate RadDiff's versatility across diverse clinical tasks, including COVID-19 phenotype comparison, racial subgroup analysis, and discovery of survival-related imaging features. Together, RadDiff and RadDiffBench provide the first method-and-benchmark foundation for systematically uncovering meaningful differences in radiological data.

cs.CV

TRoVe: Discovering Error-Inducing Static Feature Biases in Temporal Vision-Language Models

Vision-language models (VLMs) have made great strides in addressing temporal understanding tasks, which involve characterizing visual changes across a sequence of images. However, recent works have suggested that when making predictions, VLMs may rely on static feature biases, such as background or object features, rather than dynamic visual changes. Static feature biases are a type of shortcut and can contribute to systematic prediction errors on downstream tasks; as a result, identifying and characterizing error-inducing static feature biases is critical prior to real-world model deployment. In this work, we introduce TRoVe, an automated approach for discovering error-inducing static feature biases learned by temporal VLMs. Given a trained VLM and an annotated validation dataset associated with a downstream classification task, TRoVe extracts candidate static features from the dataset and scores each feature by (i) the effect of the feature on classification errors as well as (ii) the extent to which the VLM relies on the feature when making predictions. In order to quantitatively evaluate TRoVe, we introduce an evaluation framework consisting of 101 trained temporal VLMs paired with ground-truth annotations for learned static feature biases. We use this framework to demonstrate that TRoVe can accurately identify error-inducing static feature biases in VLMs, achieving a 28.6% improvement over the closest baseline. Finally, we apply TRoVe to 7 off-the-shelf VLMs and 2 temporal understanding tasks, surfacing previously-unknown static feature biases and demonstrating that knowledge of learned biases can aid in improving model performance at test time. Our code is available at https://github.com/Stanford-AIMI/TRoVe.

cs.CV

Process Reward Models for Sentence-Level Verification of LVLM Radiology Reports

Automating radiology report generation with Large Vision-Language Models (LVLMs) holds great potential, yet these models often produce clinically critical hallucinations, posing serious risks. Existing hallucination detection methods frequently lack the necessary sentence-level granularity or robust generalization across different LVLM generators. We introduce a novel approach: a sentence-level Process Reward Model (PRM) adapted for this vision-language task. Our PRM predicts the factual correctness of each generated sentence, conditioned on clinical context and preceding text. When fine-tuned on MIMIC-CXR with weakly-supervised labels, a lightweight 0.5B-parameter PRM outperforms existing verification techniques, demonstrating, for instance, relative improvements of 7.5% in Matthews Correlation Coefficient and 1.8% in AUROC over strong white-box baselines on outputs from one LVLM. Unlike methods reliant on internal model states, our PRM demonstrates strong generalization to an unseen LVLM. We further show its practical utility: PRM scores effectively filter low-quality reports, improving F1-CheXbert scores by 4.5% (when discarding the worst 10% of reports). Moreover, when guiding a novel weighted best-of-N selection process on the MIMIC-CXR test set, our PRM show relative improvements in clinical metrics of 7.4% for F1-CheXbert and 0.6% for BERTScore. These results demonstrate that a lightweight, context-aware PRM provides a model-agnostic safety layer for clinical LVLMs without access to internal activations

cs.CL

From Detection to Mitigation: Addressing Bias in Deep Learning Models for Chest X-Ray Diagnosis

Deep learning models have shown promise in improving diagnostic accuracy from chest X-rays, but they also risk perpetuating healthcare disparities when performance varies across demographic groups. In this work, we present a comprehensive bias detection and mitigation framework targeting sex, age, and race-based disparities when performing diagnostic tasks with chest X-rays. We extend a recent CNN-XGBoost pipeline to support multi-label classification and evaluate its performance across four medical conditions. We show that replacing the final layer of CNN with an eXtreme Gradient Boosting classifier improves the fairness of the subgroup while maintaining or improving the overall predictive performance. To validate its generalizability, we apply the method to different backbones, namely DenseNet-121 and ResNet-50, and achieve similarly strong performance and fairness outcomes, confirming its model-agnostic design. We further compare this lightweight adapter training method with traditional full-model training bias mitigation techniques, including adversarial training, reweighting, data augmentation, and active learning, and find that our approach offers competitive or superior bias reduction at a fraction of the computational cost. Finally, we show that combining eXtreme Gradient Boosting retraining with active learning yields the largest reduction in bias across all demographic subgroups, both in and out of distribution on the CheXpert and MIMIC datasets, establishing a practical and effective path toward equitable deep learning deployment in clinical radiology.

cs.CV

LieRE: Lie Rotational Positional Encodings

Transformer architectures rely on position encodings to model the spatial structure of input data. Rotary Position Encoding (RoPE) is a widely used method in language models that encodes relative positions through fixed, block-diagonal, rotation matrices applied to key-query interactions. We hypothesize that this inductive bias limits their RoPE's effectiveness for modalities with high dimensional structure. Lie Relative Encodings (LieRE) introduce a principled generalization of RoPE, aimed at increasing the representational capacity of positional encodings in transformers. Instead of fixed 2D rotations, LieRE learns dense skew-symmetric matrices (Lie algebra elements), which are then differentiable mapped to form high-dimensional rotation matrices (Lie group elements). This results in richer, learnable, and continuous, encodings of both relative and absolute positional information. We demonstrate the effectiveness of LieRE on 2D and 3D vision tasks, showing that it generalizes well to higher input resolutions while maintaining computational efficiency. The code and checkpoints are publicly available at https://github.com/StanfordMIMI/LieRE.

cs.CV

CheXalign: Preference fine-tuning in chest X-ray interpretation models without human feedback

Radiologists play a crucial role in translating medical images into actionable reports. However, the field faces staffing shortages and increasing workloads. While automated approaches using vision-language models (VLMs) show promise as assistants, they require exceptionally high accuracy. Most current VLMs in radiology rely solely on supervised fine-tuning. Meanwhile, additional preference fine-tuning in the post-training pipeline has become standard practice in the general domain. The challenge in radiology lies in the prohibitive cost of obtaining radiologist feedback at scale. To address this challenge, we propose an automated pipeline for preference feedback, focusing on chest X-ray radiology report generation (RRG). Specifically, our method leverages publicly available datasets containing pairs of images and radiologist-written reference reports with reference-based metrics, or Judges, eliminating the need for additional radiologist feedback. We investigate reward overoptimization via length exploitation in this setting and introduce a length-controlled version of the GREEN score. Our best-performing setup achieves state-of-the-art CheXbert scores on the MIMIC-CXR dataset for the RRG task while on average maintaining robust performance across six additional image perception and reasoning tasks.

cs.CV

MedVAE: Efficient Automated Interpretation of Medical Images with Large-Scale Generalizable Autoencoders

Medical images are acquired at high resolutions with large fields of view in order to capture fine-grained features necessary for clinical decision-making. Consequently, training deep learning models on medical images can incur large computational costs. In this work, we address the challenge of downsizing medical images in order to improve downstream computational efficiency while preserving clinically-relevant features. We introduce MedVAE, a family of six large-scale 2D and 3D autoencoders capable of encoding medical images as downsized latent representations and decoding latent representations back to high-resolution images. We train MedVAE autoencoders using a novel two-stage training approach with 1,052,730 medical images. Across diverse tasks obtained from 20 medical image datasets, we demonstrate that (1) utilizing MedVAE latent representations in place of high-resolution images when training downstream models can lead to efficiency benefits (up to 70x improvement in throughput) while simultaneously preserving clinically-relevant features and (2) MedVAE can decode latent representations back to high-resolution images with high fidelity. Our work demonstrates that large-scale, generalizable autoencoders can help address critical efficiency challenges in the medical domain. Our code is available at https://github.com/StanfordMIMI/MedVAE.

eess.IV

Automated Structured Radiology Report Generation

Automated radiology report generation from chest X-ray (CXR) images has the potential to improve clinical efficiency and reduce radiologists' workload. However, most datasets, including the publicly available MIMIC-CXR and CheXpert Plus, consist entirely of free-form reports, which are inherently variable and unstructured. This variability poses challenges for both generation and evaluation: existing models struggle to produce consistent, clinically meaningful reports, and standard evaluation metrics fail to capture the nuances of radiological interpretation. To address this, we introduce Structured Radiology Report Generation (SRRG), a new task that reformulates free-text radiology reports into a standardized format, ensuring clarity, consistency, and structured clinical reporting. We create a novel dataset by restructuring reports using large language models (LLMs) following strict structured reporting desiderata. Additionally, we introduce SRR-BERT, a fine-grained disease classification model trained on 55 labels, enabling more precise and clinically informed evaluation of structured reports. To assess report quality, we propose F1-SRR-BERT, a metric that leverages SRR-BERT's hierarchical disease taxonomy to bridge the gap between free-text variability and structured clinical reporting. We validate our dataset through a reader study conducted by five board-certified radiologists and extensive benchmarking experiments.

cs.CL