Search arXiv⌕ Search

arXiv subjects

Mijin Yun

Publications and source records attributed to Mijin Yun.

2 recordsLinked to original sources

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

cs.CV↗

Slice-Consistent 3D Volumetric Brain CT-to-MRI Translation with 2D Brownian Bridge Diffusion Model

In neuroimaging, generally, brain CT is more cost-effective and accessible imaging option compared to MRI. Nevertheless, CT exhibits inferior soft-tissue contrast and higher noise levels, yielding less precise structural clarity. In response, leveraging more readily available CT to construct its counterpart MRI, namely, medical image-to-image translation (I2I), serves as a promising solution. Particularly, while diffusion models (DMs) have recently risen as a powerhouse, they also come with a few practical caveats for medical I2I. First, DMs' inherent stochasticity from random noise sampling cannot guarantee consistent MRI generation that faithfully reflects its CT. Second, for 3D volumetric images which are prevalent in medical imaging, naively using 2D DMs leads to slice inconsistency, e.g., abnormal structural and brightness changes. While 3D DMs do exist, significant training costs and data dependency bring hesitation. As a solution, we propose novel style key conditioning (SKC) and inter-slice trajectory alignment (ISTA) sampling for the 2D Brownian bridge diffusion model. Specifically, SKC ensures a consistent imaging style (e.g., contrast) across slices, and ISTA interconnects the independent sampling of each slice, deterministically achieving style and shape consistent 3D CT-to-MRI translation. To the best of our knowledge, this study is the first to achieve high-quality 3D medical I2I based only on a 2D DM with no extra architectural models. Our experimental results show superior 3D medical I2I than existing 2D and 3D baselines, using in-house CT-MRI dataset and BraTS2023 FLAIR-T1 MRI dataset.

eess.IV↗