Search arXiv⌕ Search

arXiv subjects

Ming Chao

Publications and source records attributed to Ming Chao.

3 recordsLinked to original sources

Uncertainty-Aware Multimodal Deep Learning for Prediction of Radiation-Induced Xerostomia in Head and Neck Cancer

To develop and evaluate an uncertainty-aware multimodal learning framework for predicting radiation-induced xerostomia in patients receiving head-and-neck cancer radiotherapy. We developed a Bidirectional Attention-enhanced Diffusion Transformer (BA-DiT) that combines self-supervised multimodal representation learning with supervised Bayesian fine-tuning. The model integrates pretreatment CT images and three-dimensional dose distributions, focusing on bilateral parotid glands while incorporating surrounding anatomical and dosimetric information. During pretraining, bidirectional cross-attention integrates anatomical and dosimetric features, while a latent Diffusion Transformer learns joint representations through diffusion-based learning, feature reconstruction, and contrastive alignment. Supervised fine-tuning employs a Bayesian classifier to predict individualized xerostomia risk and quantify predictive uncertainty, with a learnable label-transition model accounting for potential toxicity label uncertainty. BA-DiT was developed using four independent cohorts (Moffitt, Emory, MSHS, and TCIA) and evaluated against baseline and ablation models. Evaluation included predictive performance, calibration, uncertainty quantification, decision curve analysis, and patient-level case studies. In independent MSHS and Emory cohorts, BA-DiT achieved AUCs of 0.83 and 0.80, respectively, outperforming baseline models. Predictive uncertainty peaked near the decision boundary, with aleatoric uncertainty being the predominant component. Uncertainty-based selective prediction generally improved net benefit among retained patients, with greater gains at lower prediction coverage. BA-DiT enables individualized xerostomia risk prediction while providing complementary uncertainty estimates, potentially supporting informed clinical decision-making and personalized toxicity management.

eess.IV↗

Multimodal Deep Learning for Uncertainty-Aware Radiation Pneumonitis Risk Prediction

Radiation pneumonitis (RP) is a potentially serious complication of thoracic radiotherapy, making reliable risk prediction important for identifying high-risk patients and guiding effective toxicity management. Although deep learning models can predict RP risk, uncertainty quantification remains underdeveloped in radiation toxicity assessment. We developed a Multimodal Bayesian Diffusion Transformer (MM-DiT) that integrates pretreatment computed tomography (CT) and three-dimensional planning dose distributions for RP risk prediction and uncertainty quantification. MM-DiT combines self-supervised multimodal representation learning with Bayesian classification to estimate individual risk and characterize aleatoric, epistemic, and label uncertainty. In independent Mount Sinai Health System (MSHS) and RTOG cohorts, MM-DiT achieved areas under the receiver operating characteristic curve (AUCs) of $0.89$ and $0.86$, respectively, with expected calibration errors of $0.02$ and $0.03$. Incorporating post-treatment CT increased AUC to $0.95$ in MSHS and reduced aleatoric and epistemic uncertainty by approximately $40-45\%$ and $40\%$, respectively. These findings establish a framework for uncertainty-aware radiation toxicity prediction that complements risk estimates with information about predictive reliability. By integrating multimodal learning and uncertainty quantification, MM-DiT may advance more interpretable and trustworthy AI-assisted toxicity assessment and support individualized radiotherapy planning.

eess.IV↗

Impact of normal lung volume choices on radiation pneumonitis risk prediction in locally advanced NSCLC radiotherapy

This study is to evaluate the impact of lung volume choices on predicting radiation pneumonitis (RP) risk in patients with locally advanced NSCLC undergoing radiotherapy. Dosimetric variables V20, V5, and mean lung dose (MLD) were extracted from the treatment plans of 442 patients enrolled in the NRG Oncology RTOG 0617 trial. Three lung volumes were defined: total lung excluding gross-tumor-target (TL-GTV), total lung excluding clinical-target-volume (TL-CTV), and total lung excluding planning-target-volume (TL-PTV). Patients were grouped as no-RP2 (N = 377, grade <= 1 RP) and RP2 (N = 65, grade >= 2 RP). Statistical analyses were performed to assess the effect on lung volume definition on RP2 prediction. Three supervised machine learning (ML) models: logistic regression (LR), k-Nearest Neighbor (kNN), and eXtreme Gradient Boosting (XGB), were used to evaluate predictive performance. Model performance was quantified using the area under the receiver operating characteristic curve (AUC), and statistical significance was tested via a bootstrap analysis. Shapley Additive Explanations (SHAP) were applied to interpret feature contributions to model predictions. Statistical analyses showed that V20 and MLD were significantly associated with RP2, while differences among volume definitions were not statistically significant. Both kNN and XGB classifiers consistently yielded higher AUC values for the TL-PTV definition compared to the other definitions, a finding supported by bootstrap analysis. SHAP analysis further indicated that V20 and MLD were the most influential predictors of RP2. Both statistical analysis and SHAP confirmed that V20 and MLD were associated with RP2. The ML models indicated that defining normal lung volume as total lung excluding PTV yielded the highest predictive performance for RP2 risk. Further validation using external datasets is warranted to confirm these findings.

physics.med-ph↗