OptoCENTAL: a standardised, bench-testing platform based on phantoms for validating optical systems aimed at clinical monitoring of the placenta

Optical imaging and spectroscopy solutions, such as near-infrared spectroscopy (NIRS) and diffuse optical tomography (DOT), have the potential to provide compact, bedside monitoring of the placenta in the clinic, thanks to recent advancements in miniaturisation and wireless wearability. This would provide neonatologist with continuous assessment of the pregnancy status in real-time, as well as tools to possibly predict delivery outcomes. We present here OptoCENTAL, a standardized platform based on multiple optical phantoms, from digital, through solid to liquid, for a comprehensive bench-testing, characterisation and validation of any photonics solution and instrumentation that aims at in vivo, clinical monitoring of the human placenta. Results: Exemplary applications of the OptoCENTAL platform on different types of optical systems, from wearable, continuous-wave devices to broadband and time-domain NIRS systems, demonstrate the flexibility of its procedures to be implemented with any setup, allowing users to compare performances across different solutions. The results also show the capability of OptoCENTAL to provide quantitative assessment of the major features required by any photonic solution for providing effective and efficient monitoring of the placenta, including basic instrument performances, quantification of monitoring accuracy, as well as depth sensitivity. OptoCENTAL represent the first-of-a-kind effort in standardising bench-testing and validation of optical imaging and spectroscopy methods in the framework of placental clinical applications, further advancing the translation of such modalities into the hospitals, as well as towards future certification and commercialisation of such technologies.

physics.med-ph

A Novel Portable and Wearable Broadband Near-Infrared Spectroscopy Device for In-Vivo Oxygenation and Metabolism Measurements

Broadband NIRS (bNIRS) is an extension of fNIRS that provides the same assessment of oxygenation biomarkers along with a valuable marker for oxygen metabolism at a cellular level, the oxidation state of cytochrome-c-oxidase (oxCCO). bNIRS implements many (100s) NIR wavelengths in the full NIR spectrum to address this and provide insight to tissue energetics. To supply these many wavelengths of light, broadband sources are required, and spectrometers are employed to distinguish power per wavelength. Current multi-channel bNIRS instruments are bulky and only semi-portable due to technological limitations. We propose a design for a bNIRS device that has been miniaturized to allow for portable use. This design leverages the innovations in photonic devices that have created a new line of microspectrometers and broadband NIR high-power LEDs; the Hamamatsu SMD-type spectrometer C14384MA and the Ushio SMBBIR45-1100 LED. This first-of-itskind device, referred to as microCYRIL (after its two predecessors CYRIL and miniCYRIL), has been developed for oxygenation and metabolism measurements with dual channel operation. To verify functionality, concentration changes in oxygenated (HbO2) and deoxygenated (HHb) haemoglobin and oxCCO were successfully tracked during a cuff-induced venous and arterial occlusion.

physics.med-ph