Search arXivSearch

arXiv subjects

R. James Cotton

Publications and source records attributed to R. James Cotton.

2 recordsLinked to original sources

Cross-Model Distillation of a Human-Pose Foundation Model from Unannotated Infant Video for Markerless 3D Pose Estimation

Spontaneous movement is one of the earliest windows onto an infant's neuromotor health, and structured clinical instruments that score it are validated early predictors of cerebral-palsy risk. However, they require specially trained raters, are time-consuming, and carry inter-rater variability. This motivates automated, video-based markerless assessment, especially as marker-based motion capture is impractical in infants. Yet the foundation models that make markerless capture possible are trained almost entirely on adults: our recent multi-view infant study found that no single model is jointly best, with strong 2D keypoint accuracy and direct 3D body recovery split across different models. While that study identifies this trade-off, it does not resolve it. Here, we perform cross-model distillation from the Sapiens 2 pose model into the SAM 3D Body model, using unannotated infant video alone. A frozen teacher supplies dense pseudo-labels, and a differentiable renderer aligns the predicted mesh to them in the training loop. On eleven held-out infants (18 sessions, 173 recordings) under our prior study's multi-view protocol, fine-tuning improves same-view 2D keypoint agreement with the Sapiens reference (median body percentage of correct keypoints @ 10px 0.22 -> 0.42, face 0.22 -> 0.42) and Procrustes-aligned mean per joint 3D position error (25.5 -> 22.2 mm). This demonstrates how cross-model distillation improves SAM 3D Body model performance on infants.

cs.CV

Biomechanical 3D Body: Self-Supervised Distillation of Biomechanical Pose from a 3D Body Foundation Model

State-of-the-art monocular body recovery methods predict mesh vertices and angles on the corresponding kinematic tree, but their outputs lack biomechanically defined joint angles that downstream applications like clinical and biomechanical analyses require. We extend an existing foundation model, SAM-3D-Body, with an additional biomechanical prediction head that, from a single RGB image, regresses the joint angles and scales of a biomechanical model. Training this model presents a challenge, as there are limited datasets of paired images and biomechanical fits. To overcome this, we supervise biomechanical outputs with in-loop optimized targets from a Levenberg-Marquardt solver performing inverse kinematics fits against markers from the mesh predictions. This allows distilling the biomechanical head from the mesh head, even from unlabeled images. To make this work with GPU-optimized biomechanical models in MuJoCo, the entire model was implemented in JAX using Equinox. We trained this distilled output head on the publicly released SAM-3D-Body dataset. We then validated this model on biomechanical fits to two publicly available marker-based datasets, MoVi and BioCV, as well as movements from a clinical cohort captured with multiview markerless motion capture. The resulting model outperforms existing models for direct regression of biomechanics from images while only slightly underperforming the state-of-the-art monocular biomechanics method that performs more costly inference-time optimization of entire trajectories.

cs.CV