Search arXivSearch

arXiv subjects

R. Loos

Publications and source records attributed to R. Loos.

6 recordsLinked to original sources

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time of arrival and time over threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

physics.ins-det

Search for millicharged particles in proton-proton collisions at $\sqrt{s} = 13.6$ TeV

We report on a search for elementary particles with charges much smaller than the electron charge using a data sample of proton-proton collisions provided by the CERN Large Hadron Collider in 2023--24, corresponding to an integrated luminosity of 124.7~fb$^{-1}$ at a center-of-mass energy of 13.6~TeV. The analysis presented uses the completed Run 3 milliQan bar detector to set the most stringent constraints to date for particles with charges $\leq0.24~\rm{e}$ and masses $\geq0.45~\rm{GeV}$.

hep-ex

Electronics design and testing of the CMS Fast Beam Condition Monitor for HL-LHC

The high-luminosity upgrade of the LHC (HL-LHC) brings unprecedented requirements for precision bunch-by-bunch luminosity measurement and beam-induced background monitoring in real time. A key component of the CMS Beam Radiation Instrumentation and Luminosity detector system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is able to operate independently at all times with a triggerless asynchronous readout. FBCM utilizes a dedicated front-end ASIC to amplify the signals from CO$_2$-cooled silicon-pad sensors with 1 ns timing resolution. Front-end (FE) electronics are subject to high-radiation conditions, thus all components are radiation hardened: sensors, ASICs, transceivers, etc. The FBCM ASIC contains 6 channels, each outputting a high-speed binary signal carrying the time-of-arrival and time-over-threshold information. This signal is sent via a gigabit optical link to the back-end electronics for analysis. A dedicated test system is designed for the FBCM FE electronics with a modular setup for all testing needs of the project from initial ASIC validation test to system-level testing with the full read-out chain. The paper reports on the design, read-out architecture, and testing program for the FBCM electronics.

physics.ins-det

The CMS Fast Beam Condition Monitor for HL-LHC

The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and data acquisition services and able to operate at all times with a triggerless readout. FBCM utilizes a dedicated front-end application-specific integrated circuit (ASIC) to amplify the signals from CO$_2$-cooled silicon-pad sensors with a timing resolution of a few nanoseconds, which enables the measurement of the beam-induced background. FBCM uses a modular design with two half-disks of twelve modules at each end of CMS, with four service modules placed close to the outer edge to reduce radiation-induced aging. The electronics system design adapts several components from the CMS Tracker for power, control and read-out functionalities. The dedicated FBCM23 ASIC contains six channels and adjustable shaping time to optimize the noise with regards to sensor leakage current. Each ASIC channel outputs a single binary high-speed asynchronous signal carrying time-of-arrival and time-over-threshold information. The chip output signal is digitized, encoded and sent via a radiation-hard gigabit transceiver and an optical link to the back-end electronics for analysis. This paper reports on the updated design of the FBCM detector and the ongoing testing program.

physics.ins-det

Sensitivity to millicharged particles in future proton-proton collisions at the LHC

We report on the expected sensitivity of dedicated scintillator-based detectors at the LHC for elementary particles with charges much smaller than the electron charge. The dataset provided by a prototype scintillator-based detector is used to characterise the performance of the detector and provide an accurate background projection. Detector designs, including a novel slab detector configuration, are considered for the data taking period of the LHC to start in 2022 (Run 3) and for the high luminosity LHC. With the Run 3 dataset, the existence of new particles with masses between 10 MeV and 45 GeV could be excluded at 95% confidence level for charges between 0.003e and 0.3e, depending on their mass. With the high luminosity LHC dataset, the expected limits would reach between 10 MeV and 80 GeV for charges between 0.0018e and 0.3e, depending on their mass

hep-ex

Search for millicharged particles in proton-proton collisions at $\sqrt{s} = 13$ TeV

We report on a search for elementary particles with charges much smaller than the electron charge using a data sample of proton-proton collisions provided by the CERN Large Hadron Collider in 2018, corresponding to an integrated luminosity of 37.5 fb$^{-1}$ at a center-of-mass energy of 13 TeV. A prototype scintillator-based detector is deployed to conduct the first search at a hadron collider sensitive to particles with charges ${\leq}0.1e$. The existence of new particles with masses between 20 and 4700 MeV is excluded at 95% confidence level for charges between $0.006e$ and $0.3e$, depending on their mass. New sensitivity is achieved for masses larger than $700$ MeV.

hep-ex