Syndrome-Resolved Decoding of Qubit Readout Errors

Readout errors in superconducting qubits include incorrect state assignment, bit flips within the computational subspace, and leakage to non-computational states. These errors require different mitigation strategies, yet conventional measurement fidelity and repeatability metrics do not resolve their individual contributions. Previous repeated-readout studies have shown that temporal correlations reveal additional information about readout errors. Here we introduce the Readout Error Decoder (RED), which converts repeated thresholded binary records into a channel-resolved error budget. Controlled error injections validate the channel-specific response of the decoder. We demonstrate RED on both fluxonium and transmon qubits and across distinct leakage-lifetime regimes. RED identifies the error channels limiting readout performance without requiring dedicated discrimination of non-computational states, providing a basis for targeted readout optimization across different qubit modalities.

quant-ph↗

Raising the Cavity Frequency in cQED

The basic element of circuit quantum electrodynamics (cQED) is a cavity resonator strongly coupled to a superconducting qubit. Since the inception of the field, the choice of the cavity frequency was, with a few exceptions, been limited to a narrow range around 7 GHz due to a variety of fundamental and practical considerations. Here we report the first cQED implementation, where the qubit remains a regular transmon at about 5 GHz frequency, but the cavity's fundamental mode raises to 21 GHz. We demonstrate that (i) the dispersive shift remains in the conventional MHz range despite the large qubit-cavity detuning, (ii) the quantum efficiency of the qubit readout reaches 8%, (iii) the qubit's energy relaxation quality factor exceeds $10^7$, (iv) the qubit coherence time reproducibly exceeds $100~μ\rm{s}$ and can reach above $300~μ\rm{s}$ with a single echoing $π$-pulse correction. The readout error is currently limited by an accidental resonant excitation of a non-computational state, the elimination of which requires minor adjustments to the device parameters. Nevertheless, we were able to initialize the qubit in a repeated measurement by post-selection with $2\times 10^{-3}$ error and achieve $4\times 10^{-3}$ state assignment error. These results encourage in-depth explorations of potentially transformative advantages of high-frequency cavities without compromising existing qubit functionality.

quant-ph↗