Search arXiv⌕ Search

arXiv subjects

Zablon Ombiro

Publications and source records attributed to Zablon Ombiro.

2 recordsLinked to original sources

Benchmarking Classical Machine Learning Models for Shading-Fault Detection in Rooftop Photovoltaic Systems Using Real Sensor Data

Most published comparisons of machine-learning classifiers for photovoltaic (PV) fault detection are validated on simulated faults. We compare seven classical and ensemble-tree classifiers on the Réunion dataset, a 4 kW domestic rooftop plant on which shading faults were physically staged and logged. Readings within a staged episode are near-duplicates, so every train/test split is grouped by episode. A 20,800-row subsample that retains all 17 fault episodes was evaluated with three repeats of five-fold group-aware nested cross-validation, with synthetic minority oversampling (SMOTE) applied inside the training folds. Random Forest and XGBoost gave the highest mean accuracy (0.838 and 0.831) and Matthews correlation coefficient (MCC; 0.526 and 0.522). After Holm correction across the 21 pairwise Wilcoxon tests, only Random Forest's accuracy advantage over k-nearest neighbours and the multi-layer perceptron remained significant. Logistic Regression and the Decision Tree (accuracy 0.820) could be separated neither from the ensembles nor from the weakest models. SMOTE lowered binary MCC for six of the seven classifiers. Errors were concentrated in whole episodes: the Random Forest almost entirely missed four of the 17 fault episodes, including one of two uniform-shading and two of five intermittent-shading episodes. A post-hoc diagnostic shows that the no-fault rows were sampled over a wider range of times of day and output levels than the fault rows. Clock time alone reaches an MCC of 0.44, and PV-side voltage alone 0.72. The reported scores therefore reflect operating-condition differences as well as shading signatures. We release the pipeline and the diagnostics, and identify matched no-fault sampling as the step needed before the classifier ranking can be generalised.

cs.LG↗

What matters in classical machine learning for non-intrusive load monitoring? A factorial benchmark on REFIT with validation on unseen houses

Published classical machine-learning results for appliance ON/OFF classification in nonintrusive load monitoring (NILM) range from F1-type scores of 0.53 to 0.98, and the sources of this spread have not been separated. This study separates them with a factorial benchmark on REFIT: seven models, two feature sets and four class-imbalance strategies for five appliances (270 fitted configurations), each evaluated by pooled nested cross-validation and on houses unseen during training, with robustness checks. An analysis of variance shows that the appliance explains 38% of the variance in F1, the feature set 13% and the model only 8%. Engineered rolling-window features raised the mean F1 score by 52% under both protocols. Other conclusions changed on unseen houses: the support-weighted F1 score of the best pooled configurations fell from 0.548 to 0.447, the differences between the models selected by pooled validation were no longer significant, and the benefit of class weighting over no correction rose from 32% to 69%. In a nested comparison, house-grouped selection on the training houses improved F1 on unseen houses for three of five appliances, by up to 0.110, and was within 0.007 for the other two. These findings held across four house partitions and without the solar-affected houses. A same-protocol convolutional network reached a weighted F1 score of 0.50, about 0.05 above the classical models (0.45) and far below the published deep-learning scores of 0.78 to 0.91, which were obtained under a different protocol. The results support low-cost appliance monitoring in buildings and yield a NILM reporting checklist.

cs.LG↗