Search arXiv⌕ Search

arXiv subjects

Zachary Shah

Publications and source records attributed to Zachary Shah.

6 recordsLinked to original sources

A closed-loop agentic research environment for MRI development within Siemens IDEA platform

Motivation: Testing new ideas in MRI can require substantial effort to learn sequence programming and reconstruction tools and to debug implementations before the scientific question can be addressed. Goals: Reduce the implementation and debugging burden of testing MRI ideas while retaining researcher control of scientific decisions. Approach: We developed an environment where LLM agents develop sequences in the native Siemens IDEA platform, evaluate them through Bloch simulation and reconstruction, and further iteratively refine them using scanner feedback. Results: As test cases, the agentic environment was used to implement and validate a GIRF-based gradient-calibration sequence and reconstruction in approximately 4 hours, and to develop and optimize a rapid 3-second multichannel calibration scan in approximately 12 hours of researcher-guided iteration.

eess.SP↗

FESTiVE: Self-calibrated Spatial-temporal Gradient Characterization for Non-cartesian Imaging on High Performance Systems

Gradient imperfections disrupt the encoding benefits of long-readout imaging applications on high-performance systems. Currently, external field monitoring hardware provides the only reliable solution for general spatial-temporal gradient characterization. We present FESTiVE, a data-driven alternative to higher-order field monitoring. FESTiVE leverages parallel imaging to both implicitly model and explicitly recover field imperfections. Using a fast k-t mapping calibration scan, FESTiVE formulates a time-varying GRAPPA problem which maps k-space data corrupted by a time-varying gradient imperfection against a clean reference. This mapping is represented compactly with an implicit neural representation, from which the spatial-temporal fields are recovered in image space using coil sensitivities. In phantom, FESTiVE produces comparable field measurements to a Skope field camera across multiple non-cartesian 2D acquisition strategies and gradient specifications. In vivo, FESTiVE achieves state-of-the-art image quality for a high-performance diffusion spiral protocol on the head-only MAGNUS 3T, where higher-order phase imperfections are significant. At 7T, on the head-only Siemens TerraX system, FESTiVE enables 300μm spiral imaging where conventional field camera-based approaches fall below probe dephasing limits. In conclusion, FESTiVE enables robust high-resolution non-cartesian imaging on high-performance gradients, characterizing gradient imperfections using parallel imaging rather than field monitoring hardware.

eess.SP↗

Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTI

High-performance head-only gradient systems can substantially reduce echo spacing (ESP) in echo-planar imaging (EPI), but the resulting encoding speed is typically used to shorten readouts and reduce distortion. Here, we instead leverage the increased echo budget to enable denser k-space sampling and higher simultaneous-multislice (SMS) acceleration in SMS-EPI and SMS-EPTI. Fast k-space traversal with denser ky-kz sampling is achieved using peripheral nerve stimulation (PNS)-optimized gradient waveforms, while high-quality reconstruction is obtained using field-correcting GRAPPA (FCG). The resulting ESPs on MAGNUS 3T and Impulse 7T are approximately half those of high-performance whole-body systems, enabling approximately 2-fold higher multiband (MB) acceleration. This facilitates high-quality 2.5-mm isotropic whole-brain resting-state fMRI at 7T with MB28 and a repetition time (TR) of 123 ms.

eess.SP↗

Accelerating MRI with Longitudinally-informed Latent Posterior Sampling

Purpose: To accelerate MRI acquisition by incorporating the previous scans of a subject during reconstruction. Although longitudinal imaging constitutes much of clinical MRI, leveraging previous scans is challenging due to the complex relationship between scan sessions, potentially involving substantial anatomical or pathological changes, and the lack of open-access datasets with both longitudinal pairs and raw k-space needed for training deep learning-based reconstruction models. Methods: We propose a diffusion-model-based reconstruction framework that eliminates the need for longitudinally paired training data. During training, we treat all scan timepoints as samples from the same distribution, therefore requiring only standalone images. At inference, our framework integrates a subject's prior scan in magnitude DICOM format, which is readily available in clinical workflows, to guide reconstruction of the follow-up. To support future development, we introduce an open-access clinical dataset containing multi-session pairs including prior DICOMs and follow-up k-space. Results: Our method consistently outperforms both longitudinal and non-longitudinal baseline reconstruction methods across various accelerated Cartesian acquisition strategies. In imaging regions highly similar to the prior scan, we observe up to 10\% higher SSIM and 2 dB higher PSNR, without degradation in dissimilar areas. Compared to longitudinal reconstruction baselines, our method demonstrates robustness to varying degrees of anatomical change and misregistration. Conclusion: We demonstrate that prior scans can be effectively integrated with state-of-the-art diffusion-based reconstruction methods to improve image quality and enable greater scan acceleration, without requiring an extensive longitudinally-paired training dataset.

eess.IV↗

Subtractive Training for Music Stem Insertion using Latent Diffusion Models

We present Subtractive Training, a simple and novel method for synthesizing individual musical instrument stems given other instruments as context. This method pairs a dataset of complete music mixes with 1) a variant of the dataset lacking a specific stem, and 2) LLM-generated instructions describing how the missing stem should be reintroduced. We then fine-tune a pretrained text-to-audio diffusion model to generate the missing instrument stem, guided by both the existing stems and the text instruction. Our results demonstrate Subtractive Training's efficacy in creating authentic drum stems that seamlessly blend with the existing tracks. We also show that we can use the text instruction to control the generation of the inserted stem in terms of rhythm, dynamics, and genre, allowing us to modify the style of a single instrument in a full song while keeping the remaining instruments the same. Lastly, we extend this technique to MIDI formats, successfully generating compatible bass, drum, and guitar parts for incomplete arrangements.

cs.SD↗

ACE-Net: AutofoCus-Enhanced Convolutional Network for Field Imperfection Estimation with application to high b-value spiral Diffusion MRI

Spatiotemporal magnetic field variations from B0-inhomogeneity and diffusion-encoding-induced eddy-currents can be detrimental to rapid image-encoding schemes such as spiral, EPI and 3D-cones, resulting in undesirable image artifacts. In this work, a data driven approach for automatic estimation of these field imperfections is developed by combining autofocus metrics with deep learning, and by leveraging a compact basis representation of the expected field imperfections. The method was applied to single-shot spiral diffusion MRI at high b-values where accurate estimation of B0 and eddy were obtained, resulting in high quality image reconstruction without need for additional external calibrations.

physics.med-ph↗