Search arXivSearch

arXiv · 0811.3201

Fabrication and Test of Pixelated CZT Detectors with Different Pixel Pitches and Thicknesses

Abstract

The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High Pressure Bridgman (HPB) processes, respectively. In this contribution, the readout system based on two 32-channel NCI-ASICs for pixellated CZT detector arrays has been developed and tested. The CZT detectors supplied by Orbotech (MHB) and eV products (HPB) are tested by NCI-ASIC readout system. The CZT detectors have an array of 8x8 or 11x11 pixel anodes fabricated on the anode surface with the area up to 2 cm x2 cm and the thickness of CZT detectors ranges from 0.5 cm to 1 cm. Energy spectra resolution and electron mobility-lifetime products of 8x8 pixels CZT detector with different thicknesses have been investigated.

Explore related subjects

Keep this discovery

BibTeXRIS

Q. Li, A. Garson, P. Dowkontt, J. Martin, M. Beilicke, I. Jung, M. Groza, A. Burger, G. De Geronimo, H. Krawczynski, .. 2008-11-19. Fabrication and Test of Pixelated CZT Detectors with Different Pixel Pitches and Thicknesses. https://arxiv.org/abs/0811.3201

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

HX-POL - A Balloon-Borne Hard X-Ray Polarimeter

We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.

astro-ph

Quintessence models with an oscillating equation of state and their potentials

In this paper, we investigate the quintessence models with an oscillating equation of state (EoS) and their potentials. From the constructed potentials, which have the EoS of $ω_ϕ=ω_0+ω_1\sin z$, we find they are all the oscillating functions of the field $ϕ$, and the oscillating amplitudes are decreasing (or increasing) with $ϕ$. From the evolutive equation of the field $ϕ$, we find this is caused by the expansion of the universe. This also makes that it is very difficult to build a model whose EoS oscillates forever. However one can build a model with EoS oscillating for a period. Then we discuss three quintessence models, which are the combinations of the invert power law functions and the oscillating functions of the field $ϕ$. We find they all follow the oscillating EoS.

astro-ph

Is "Spike" a Reliable Feature in Porb Distribution of AM HER Stars?

Orbital periods in AM Her stars (polars) are synchronized with spin periods of white dwarf by its high magnetic field. Since the last study of Porb distribution of these systems, the number of known objects of such type has more than doubled. This challenged us to compile a new updated catalogue of cataclysmic variables with highly magnetic white dwarfs (polars) and to study their Porb distribution. In this paper we also discus if "spike" is reliable feature in the distribution. ("Spike" is a concentration of polars in the distribution of their orbital periods near Porb = 114 min and was previously discussed by Ritter & Kolb (1992) and Shahbaz & Wood (1996).)

astro-ph