Search arXivSearch

arXiv subjects

M. Groza

Publications and source records attributed to M. Groza.

7 recordsLinked to original sources

Scintillation properties of SrI_2(Eu^2+) (Strontium iodide doped with europium) for high energy astrophysical detectors: Nonproportionality as a function of temperature and at high gamma-ray energies

Strontium iodide doped with europium is a new scintillator material being developed as an alternative to lanthanum bromide doped with cerium for use in high energy astrophysical detectors. As with all scintillators, the issue of nonproportionality is important because it affects the energy resolution of the detector. In this study, we investigate how the nonproportionality of strontium iodide doped with europium changes as a function of temperature 16 deg. C to 60 deg. C by heating the strontium iodide doped with europium scintillator separate from the photomultiplier tube. In a separate experiment, we also investigate the nonproportionality at high energies (up to 6 MeV) of strontium iodide doped with europium at a testing facility located at NASA Goddard Space Flight Center. We find that the nonproportionality increases nearly monotonically as the temperature of the strontium iodide doped with europium scintillator is increased, although there is evidence of non-monotonic behavior near 40 deg. C, perhaps due to electric charge carriers trapping in the material. We also find that within the energy range of 662 keV to 6.1 MeV, the change in the nonproportionality of the strontium iodide doped with europium is about 1.5 to 2 percent.

physics.ins-det

Fabrication and Test of Pixelated CZT Detectors with Different Pixel Pitches and Thicknesses

The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High Pressure Bridgman (HPB) processes, respectively. In this contribution, the readout system based on two 32-channel NCI-ASICs for pixellated CZT detector arrays has been developed and tested. The CZT detectors supplied by Orbotech (MHB) and eV products (HPB) are tested by NCI-ASIC readout system. The CZT detectors have an array of 8x8 or 11x11 pixel anodes fabricated on the anode surface with the area up to 2 cm x2 cm and the thickness of CZT detectors ranges from 0.5 cm to 1 cm. Energy spectra resolution and electron mobility-lifetime products of 8x8 pixels CZT detector with different thicknesses have been investigated.

astro-ph

Detailed Studies of Pixelated CZT Detectors Grown with the Modified Horizontal Bridgman Method

The detector material Cadmium Zinc Telluride (CZT), known for its high resolution over a broad energy range, is produced mainly by two methods: the Modified High-Pressure Bridgman (MHB) and the High-Pressure Bridgman (HPB) process. This study is based on MHB CZT substrates from the company Orbotech Medical Solutions Ltd. with a detector size of 2.0x2.0x0.5 cm^3, 8x8 pixels and a pitch of 2.46 mm. Former studies have emphasized only on the cathode material showing that high-work-function improve the energy resolution at lower energies. Therfore, we studied the influence of the anode material while keeping the cathode material constant. We used four different materials: Indium, Titanium, Chromium and Gold with work-functions between 4.1 eV and 5.1 eV. The low work-function materials Indium and Titanium achieved the best performance with energy resolutions: 2.0 keV (at 59 keV) and 1.9 keV (at 122 keV) for Titanium; 2.1 keV (at 59 keV) and 2.9 keV (at 122 keV) for Indium. These detectors are very competitive compared with the more expensive ones based on HPB material if one takes the large pixel pitch of 2.46 mm into account. We present a detailed comparison of our detector response with 3-D simulations, from which we determined the mobility-lifetime-products for electrons and holes. Finally, we evaluated the temperature dependency of the detector performance and mobility-lifetime-products, which is important for many applications. With decreasing temperature down to -30C the breakdown voltage increases and the electron mobility-lifetime-product decreases by about 30% over a range from 20C to -30C. This causes the energy resolution to deteriorate, but the concomitantly increasing breakdown voltage makes it possible to increase the applied bias voltage and restore the full performance.

astro-ph

Test of Thick Pixelated Orbotech Detectors with and without Steering Grids

We report here on the optimization of 0.5 cm thick pixelated Orbotech CZT detectors with regards to the best contacting materials and the use of steering grids. We evaluated the performance of different contacting materials. Our study differs from earlier ones in that we investigated the performance of different anode and cathode materials separately. We obtain the best performance with Au cathodes. For different anode materials Ti and In give the best energy resolutions. The detector (2.0 x 2.0 x 0.5 cm, 8 x 8 pixels) shows excellent 59 keV, 122 keV and 662 keV energy resolutions of 1.4 keV, 1.9 keV, and 7.4 keV, respectively. Furthermore, we report on using steering grids to improve on the performance of the pixelated detectors. Previously, the benefit of steering grids had been limited by additional electronic noise associated with currents between the negatively biased steering grids and the anode pixels. We are currently exploring the possibility to isolate the steering grid from the CZT substrates by a thin layer of Al$_2$O$_3$. We performed a series of measurements to determine by how much the isolation layer reduces the grid-pixel currents. Comparing the currents between two Au contacts before and after isolating one of the two contacts from the CZT with a 700 nm thick layer of Al2O3, we measure that the isolation layer reduces the currents by a factor of about 10 at 500 V. We present some results from a detector before and after deposition of an isolated steering grid. The grid indeed improves on the detectors energy resolution and detection efficiency. We show that simulations can be used to model the anode to cathode charge correlation in excellent agreement with the experimental results.

astro-ph

Thick Pixelated CZT Detectors With Isolated Steering Grids

We explore the possibility to improve the performance of 0.5 cm thick Cadmium Zinc Telluride (CZT) detectors with the help of steering grids on the anode side of the detectors. Steering grids can improve the energy resolution of CZT detectors by enhancing the small pixel effect; furthermore, they can increase their detection efficiency by steering electrons to the anode pixels which otherwise would drift to the area between pixels. Previously, the benefit of steering grids had been compromised by additional noise associated with currents between the steering grids and the anode pixels. We use thin film deposition techniques to isolate the steering grid from the CZT substrate by a 150 nm thick layer of the isolator Aluminiumoxide. While the thin layer does not affect the beneficial effect of the steering grid on the weighting potentials and the electric field inside the detector, it suppresses the currents between the steering grid and the anode pixels. In this contribution, we present first results from a 2 x 2 x 0.5 cm CZT detector with 8 x 8 pixels that we tested before and after deposition of an isolated steering grid. The steering grid improves the 662 keV energy resolution of the detector by a factor of 1.3 (from about 2% to about 1.5%), while not reducing the detection efficiency. To gain further insights into the detector response in the region between pixels, we measured energy spectra with a collimated Cs137 source. The collimator measurements can be used to enhance our understanding of energy spectra measured under flood illumination of the detectors.

astro-ph

Direct comparison of the performance of CZT detectors contacted with various metals

Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good energy resolution over the broad energy range from several keV into the MeV energy range. In this paper we present the results of a systematic study of the performance of CZT detectors manufacturered by Orbotech (before IMARAD) depending on surface preparation, contact materials and contact deposition. The standard Orbotech detectors have the dimension of 2.0 x 2.0 x 0.5 cm. They have a pixellated In anode with 8 x 8 pixels and a monolithic In cathode. Using the same CZT substrates several times, we have made a direct comparison of the performance of different contact materials by replacing the cathode and/or the anode contacts with several high-workfunction metals. We present the performance of the detectors and conclude with an overview over our ongoing detector optimization.

astro-ph

Thick CZT Detectors for Space-Borne X-ray Astronomy

Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to 600 keV. In this paper, we briefly review the historical development of detectors used in X-ray astronomy. Subsequently, we present an evaluation of CZT detectors from the company Imarad. The standard 2x2x0.5 cm detectors, contacted with 8x8 In pixels and an In cathode, exhibit FWHM energy resolutions of 7 keV at 59 keV, and 10 keV at 662 keV. A direct measurement of the 662 keV photopeak efficiency gives 67%. We have started a detailed study of the performance of Imarad detectors depending on surface preparation, contact materials, contact deposition, post-deposition detector annealing, and detector passivation techniques. We present first results from contacting detectors with Cr, Ag, Au, and Pt.

astro-ph