Search arXivSearch

arXiv · 1907.04432

A new scheme for fixed node diffusion quantum Monte Carlo with pseudopotentials: improving reproducibility and reducing the trial-wave-function bias

Abstract

Fixed node diffusion quantum Monte Carlo (FN-DMC) is an increasingly used computational approach for investigating the electronic structure of molecules, solids, and surfaces with controllable accuracy. It stands out among equally accurate electronic structure approaches for its favorable cubic scaling with system size, which often makes FN-DMC the only computationally affordable high-quality method in large condensed phase systems with more than 100 atoms. In such systems FN-DMC deploys pseudopotentials to substantially improve efficiency. In order to deal with non-local terms of pseudopotentials, the FN-DMC algorithm must use an additional approximation, leading to the so-called localization error. However, the two available approximations, the locality approximation (LA) and the T-move approximation (TM), have certain disadvantages and can make DMC calculations difficult to reproduce. Here we introduce a third approach, called the determinant localization approximation (DLA). DLA eliminates reproducibility issues and systematically provides good quality results and stable simulations that are slightly more efficient than LA and TM. When calculating energy differences -- such as interaction and ionization energies -- DLA is also more accurate than the LA and TM approaches. We believe that DLA paves the way to the automization of FN-DMC and its much easier application in large systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrea Zen, Jan Gerit Brandenburg, Angelos Michaelides, Dario Alfè. 2019-09-12. A new scheme for fixed node diffusion quantum Monte Carlo with pseudopotentials: improving reproducibility and reducing the trial-wave-function bias. https://doi.org/10.1063/1.5119729

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

A subcell-refined entropy-residual-driven limiting strategy for high-order discontinuous Galerkin methods

Fine-grained, subcell-level dissipation control is essential for achieving robust high-order discontinuous Galerkin (DG) simulations of nonlinear hyperbolic systems in under-resolved regimes while preserving accuracy. This paper proposes a subcell-refined entropy-residual-driven limiting strategy for DG on Legendre-Gauss-Lobatto nodes. The limiter introduces only nearest-neighbor pairwise dissipation within each element, with closed-form coefficients that supply the minimal dissipation required to restore the element entropy inequality. The strategy is a diagonal, locally stable approximation of classical entropy-stable methods, and a generalized subcell framework reveals split-form DG and residual-distribution-based entropy correction schemes as particular choices of the limiting coefficients. For the Euler equations, a physically consistent jump operator separately models thermal and shear entropy production while preserving velocity and pressure equilibrium; a subcell refinement of the Zhang-Shu positivity limiter ensures pointwise positivity. Extensive numerical tests confirm that the scheme maintains optimal high-order accuracy, strictly enforces entropy dissipation, and significantly reduces the difficulty of a posteriori positivity-preserving procedures.

physics.comp-ph

VNS Tokamak for Medical Isotope Production

The Volumetric Neutron Source (VNS) tokamak is a proposed fusion reactor for testing components under fusion neutron irradiation, and has potential use for radioisotope production. The VNS geometry is modeled in the Serpent 2.2.2 and OpenMC 0.15.2 neutronics codes. Coupled neutron-photon simulations compared fluxes, spectra, and selected reaction rates in the blanket and vacuum vessel. Good agreement was found overall, with the largest difference found in (n, 2n) reactions. On an HPC cluster, Serpent 2 was found to have shorter computation time in coupled simulations, while OpenMC was faster in neutron only simulations. Radioisotope production yields were simulated in Serpent 2.2.2 for capsule and Cobalt plate irradiation facilities. Results indicate potential for large volume production of 99Mo, 131I, 225Ac, 177Lu, 192Ir, 64Cu, 67Cu, 161Tb, and 153Sm while 203Pb indicates lower potential. 100Mo and LEU target heating was calculated, suggesting the LEU target mass or the cooling may need adjustment. Optimized 60Co production yielded 1.2 GBq/mg and 100,000 TBq after a 3-year irradiation period. Sensitivity to plant outage for 99Mo, 131I, 177Lu, and 60Co was simulated, suggesting irradiation can be restarted for the same isotope loading and demonstrated long-lived 60Co to be robust to long plant dwell-time.

physics.comp-ph

MadVfold: accelerating NLO event generation and reducing negative weights with SIMD vectorization and GPUs

NLO simulations are essential for LHC physics analyses but are expensive, as they are not only slow but also lead to negative weights, which imply the need to simulate much larger samples of events. Folding is a powerful technique to reduce negative weights but is itself expensive. In this paper I propose ``vectorized folding'' as a new idea to speed up these calculations using SIMD and GPUs, and I present its CUDACPP-based implementation for MG5aMC in MadVfold, including its extension for unfolded NLO event generation. Preliminary results show overall speedups around 6x to 9x with folding and 3x without it. This work is based on a test-centric, LLM-assisted software development process.

physics.comp-ph