Search arXivSearch

arXiv · 1912.08739

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Abstract

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for "far detectors" of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D. L. Adams, M. Baird, G. Barr, N. Barros, A. Blake, E. Blaufuss, A. Booth, D. Brailsford, N. Buchanan, B. Carls, H. Chen, M. Convery, G. De Geronimo, T. Dealtry, R. Dharmapalan, Z. Djurcic, J. Fowler, S. Glavin, R. A. Gomes, M. C. Goodman, M. Graham, L. Greenler, A. Hahn, J. Hartnell, R. Herbst, A. Higuera, A. Himmel, J. Insler, J. Jacobsen, T. Junk, B. Kirby, J. Klein, V. A. Kudryavtsev, T. Kutter, Y. Li, X. Li, S. Lin, N. McConkey, C. A. Moura, S. Mufson, N. Nambiar, J. Nowak, M. Nunes, R. Paulos, X. Qian, O. Rodrigues, W. Sands, G. Santucci, R. Sharma, G. Sinev, N. J. C. Spooner, I. Stancu, D. Stefan, J. Stewart, J. Stock, T. Strauss, R. Sulej, Y. Sun, M. Thiesse, L. F. Thompson, Y. T. Tsai, R. Van Berg, T. Vieira, M. Wallbank, H. Wang, Y. Wang, T. K. Warburton, D. Wenman, D. Whittington, R. J. Wilson, M. Worcester, T. Yang, B. Yu, C. Zhang. 2020-03-02. Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors. https://doi.org/10.1088/1748-0221%2F15%2F03%2Fp03035

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det