Search arXivSearch

arXiv · 2006.01999

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

Abstract

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100$\%$ fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 $μ$m width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. The experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Artur Apresyan, Wei Chen, Gabriele D'Amen, Karri Folan Di Petrillo, Gabriele Giacomini, Ryan Heller, Hakseong Lee, Sergey Los, Chang-Seong Moon, Alessandro Tricoli. 2020-11-06. Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam. https://doi.org/10.1088/1748-0221%2F15%2F09%2Fp09038

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det