Search arXivSearch

arXiv · 2009.14696

Silicon carbide diodes for neutron detection

Abstract

In the last two decades we have assisted to a rush towards finding a He3-replacing technology capable of detecting neutrons emitted from fissile isotopes. The demand stems from applications like nuclear war-head screening or preventing illicit traffic of radiological materials. Semiconductor detectors stand among the stronger contenders, particularly those based on materials possessing a wide band gap like silicon carbide. We review the workings of SiC-based neutron detectors, along with several issues related to material properties, device fabrication and testing. The paper summarizes the experimental and theoretical work carried out within the E-SiCure project, co-funded by the NATO SPS Programme. Among the achievements, we have the development of successful Schottky barrier based detectors and the identification of the main carrier life-time-limiting defects in the SiC active areas, either already present in pristine devices or introduced upon exposure to radiation fields. The physical processes involved in neutron detection are described. Material properties as well as issues related to epitaxial growth and device fabrication are addressed. The presence of defects in as-grown material, as well as those introduced by ionizing radiation are reported. We finally describe several experiments carried out at the Jozef Stefan Institute TRIGA Mark II reactor (Ljubljana, Slovenia), where a set of SiC-based neutron detectors were tested, some of which being equipped with a thermal neutron converter layer. We show that despite the existence of large room for improvement, Schottky barrier diodes based on state-of-the-art 4H-SiC are closing the gap regarding the sensitivity offered by gas-based and that of semiconductor detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

José Coutinho, Vitor J. B. Torres, Ivana Capan, Tomislav Brodar, Zoran Ereš, Robert Bernat, Vladimir Radulović, Klemen Ambrožič, Luka Snoj, Željko Pastuović, Adam Sarbutt, Takeshi Ohshima, Yuichi Yamazaki, Takahiro Makino. 2020-10-30. Silicon carbide diodes for neutron detection. https://doi.org/10.1016/j.nima.2020.164793

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det