Search arXivSearch

arXiv · 2207.08824

Energy-Motivated Equivariant Pretraining for 3D Molecular Graphs

Abstract

Pretraining molecular representation models without labels is fundamental to various applications. Conventional methods mainly process 2D molecular graphs and focus solely on 2D tasks, making their pretrained models incapable of characterizing 3D geometry and thus defective for downstream 3D tasks. In this work, we tackle 3D molecular pretraining in a complete and novel sense. In particular, we first propose to adopt an equivariant energy-based model as the backbone for pretraining, which enjoys the merits of fulfilling the symmetry of 3D space. Then we develop a node-level pretraining loss for force prediction, where we further exploit the Riemann-Gaussian distribution to ensure the loss to be E(3)-invariant, enabling more robustness. Moreover, a graph-level noise scale prediction task is also leveraged to further promote the eventual performance. We evaluate our model pretrained from a large-scale 3D dataset GEOM-QM9 on two challenging 3D benchmarks: MD17 and QM9. Experimental results demonstrate the efficacy of our method against current state-of-the-art pretraining approaches, and verify the validity of our design for each proposed component.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rui Jiao, Jiaqi Han, Wenbing Huang, Yu Rong, Yang Liu. 2022-11-29. Energy-Motivated Equivariant Pretraining for 3D Molecular Graphs. https://arxiv.org/abs/2207.08824

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

BreCol: Benchmarking Classical and Deep-Learning Methods for Microbiome-Based Cancer Detection

DNA sequencing of the gut microbial community shows promise for cancer detection, but questions remain about the generalizability of results across studies. We propose BreCol, a benchmark of 2,040 16S rRNA gene sequencing runs across 26 studies spanning breast cancer, colorectal cancer, and healthy cohorts. Train-test splits are made within pre-2023 studies, while holdout evaluation uses studies from 2023 onward, reflecting temporal separation from training data. Classical models reach test/holdout AUCs of 0.77/0.60 for cancer diagnosis and 1.00/0.83 for cancer type prediction. We train the models on both cancer types simultaneously and find that colorectal cancer is often easier to detect than breast cancer. We also evaluate two deep learning models: HyenaDNA, a long-range sequence model that pools hidden states for classification, and SetBERT, a transformer that produces contextualized embeddings over sets of reads. Both deep learning models underperform the best classical methods on holdout data, though tuning training set size and the classification head yields modest gains. Our classical pipeline uses unsupervised clustering to derive features from tetramer frequencies, preserving within-run compositional signal and achieving near state-of-the-art performance without relying on taxonomic assignments. BreCol data and associated code are publicly available.

q-bio.QM

Topological Inference for Organoids

The reproducibility of organ morphology and the extent to which computational models can predict morphogenesis remain difficult to quantify, particularly for organs with complex networks of fluid-filled lumina. Here, we combine Topological Data Analysis (TDA), biophysical simulation, and Bayesian inference to study lumen morphogenesis in pancreatic organoids. Lumen formation is governed by physical processes that are challenging to measure directly, including cell proliferation and luminal osmotic pressure. We simulate organoid development using a phase-field model and address the inverse problem of inferring these parameters from either time-lapse images or single morphological snapshots. Since lumen architectures vary substantially in size, structure, and connectivity, conventional geometric descriptors provide only a partial representation of their morphology. We therefore represent each organoid using SampEuler, a topological descriptor derived from the Euler Characteristic Transform (ECT). We first show that SampEuler captures morphological information encoded by established morphometrics. We then perform parameter inference using an approximate Bayesian computation (ABC) rejection framework with the SampEuler Wasserstein distance. Using synthetic organoids with known ground-truth parameters, our approach accurately recovers the osmotic pressure and the proliferation rate while revealing a compensatory trade-off between the two processes. Applied to experimental data from ten pancreatic organoids, the inferred posterior distributions are consistent with biological expectations. Together, these results establish a non-destructive, image-based pipeline for estimating otherwise inaccessible physical parameters governing lumen formation and highlight the potential of topological representations for linking complex biological morphology to mechanistic models.

q-bio.QM

Circadian Derived Features for Early Discrimination Across Insomnia Severity Levels: At Least 8 Weeks of Monitoring Are Needed for Clinically Meaningful Assessment

Background: Wearable devices provide continuous, objective measures of daily activity and offer promise for assessing sleep disorders. However, the minimum monitoring duration needed to differentiate insomnia severity remains unclear. We investigated when wearable-derived behavioral features become informative for distinguishing Insomnia Severity Index (ISI) categories and examined the contribution of Activity Count (AC) and circadian-derived features. Methods: We analyzed wearable data from 2,305 participants in the Advancing Understanding of Recovery after Trauma (AURORA) study. Separate binary classifiers were developed for four ISI categories across six follow-up periods using AC and circadian-derived feature sets. Performance was evaluated using accuracy, F1-score, precision, recall, and AUROC. Results: Classification improved with longer monitoring. Across ISI categories, approximately eight weeks was the earliest time point at which wearable-derived features consistently achieved informative discrimination, with modest improvements thereafter. Participants without clinically significant insomnia were easiest to identify, reaching an AUROC of 0.693. Circadian-derived features performed comparably to, and in several cases better than, AC features, suggesting that the temporal organization of daily activity provides information beyond overall activity volume. Conclusions: Approximately eight weeks of longitudinal wearable monitoring may represent a practical minimum for differentiating ISI-defined insomnia categories. Longer monitoring provided only incremental improvements. Circadian behavioral features show promise as digital biomarkers for objective insomnia assessment.

q-bio.QM