Search arXivSearch

arXiv · 2310.17231

Bridgman-grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A comparison of suitability for X and gamma detectors

Abstract

This study explores the suitability of semi-insulating compounds, specifically (Cd,Mn)Te and (Cd,Mn)(Te,Se), as materials for room temperature X-ray and gamma-ray detectors. These compounds were grown using the Bridgman method, known for its efficient growth rate. The investigation aims to compare their crystal structure, mechanical properties, optical characteristics, and radiation detection capabilities. The addition of selenium to (Cd,Mn)Te increased the compound's hardness. However, (Cd,Mn)(Te,Se) exhibited one order of magnitude higher etch pit density compared to (Cd,Mn)Te. Photoluminescence analysis at low temperatures revealed the presence of defect states in both materials, characterized by shallow and deep donor-acceptor pair transitions (DAP). Annealing in cadmium vapors effectively eliminated DAP luminescence in (Cd,Mn)Te but not in (Cd,Mn)(Te,Se). Spectroscopic performance assessments indicated that the (Cd,Mn)Te detector outperformed the (Cd,Mn)(Te,Se) detector in responding to a Co-57 source. The reduced performance in the latter case may be attributed to either the presence of a deep trap related to deep DAP luminescence, minimally affected by annealing, or the dominant presence of block-like structures in the samples, as indicated by X-ray diffraction measurements. The block-like structures in (Cd,Mn)(Te,Se) showed ten times larger misorientation angles compared to the (Cd,Mn)Te crystals. (Cd,Mn)Te crystal revealed excellent single crystal properties, demonstrated by narrower omega scan widths. The study also highlights the influence of grain boundaries and twins on crystal structure quality. In our opinion, Bridgman-grown (Cd,Mn)Te shows greater promise as a material for X-ray and gamma-ray detectors compared to (Cd,Mn)(Te,Se).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Aneta Maslowska, Dominika M. Kochanowska, Adrian Sulich, Jaroslaw Z. Domagala, Marcin Dopierala, Michal Kochanski, Michal Szot, Witold Chrominski, Andrzej Mycielski. 2023-10-26. Bridgman-grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A comparison of suitability for X and gamma detectors. https://doi.org/10.3390/s24020345

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph

Pendellösung length-scale neutron and X-ray interferometry

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-ph