Search arXivSearch

arXiv · 2312.09097

Advanced magnetocaloric microwires: What does the future hold?

Abstract

Magnetic refrigeration (MR) based on the magnetocaloric effect (MCE) is a promising alternative to conventional vapor compression refrigeration techniques. The cooling efficiency of a magnetic refrigerator depends on its refrigeration capacity and operation frequency. Existing refrigerators possess limited cooling efficiency due to the low operating frequency (around tens of Hz). Theory predicts that reducing geometrical effects can increase the operation frequency by reducing the relaxation time of a magnetic material. As compared to other shapes, magnetocaloric wires transfer heat most effectively to a surrounding environment, due to their enhanced surface area. The wire shape also yields a good mechanical response, reducing the relaxation time and consequently increasing the operation frequency of the cooling device. Experiments have validated the theoretical predictions. By assembling microwires with different magnetocaloric properties and Curie temperatures into a laminate structure, a table-like magnetocaloric bed can be created and used as an active cooling device for micro-electro-mechanical system (MEMS) and nano-electro-mechanical system (NEMS). This paper assesses recent progress in the development of magnetocaloric microwires and sheds light on the important factors affecting the magnetocaloric behavior and cooling efficiency in microwire systems. Challenges, opportunities, and strategies regarding the development of advanced magnetocaloric microwires are also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hongxian Shen, Nguyen Thi My Duc, Hillary Belliveau, Lin Luo, Yunfei Wang, Jianfei Sun, Faxiang Qin, Manh-Huong Phan. 2023-12-14. Advanced magnetocaloric microwires: What does the future hold?. https://doi.org/10.31276/vjste.65(4).14-24

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph

Pendellösung length-scale neutron and X-ray interferometry

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-ph