Search arXivSearch

arXiv · 2402.01544

Pre-Flight Calibration of PIXL for X-ray Fluorescence Elemental Quantification

Abstract

The Planetary Instrument for X-ray Lithochemistry (PIXL) is a rasterable focused-beam X-ray fluorescence (XRF) spectrometer mounted on the arm of National Aeronautics and Space Administration's (NASA) Mars 2020 Perseverance rover. To ensure that PIXL would be capable of performing accurate in-flight compositional analysis of martian targets, in situ, an elemental calibration was performed pre-flight on the PIXL flight instrument in a simulated martian environment. The details of this calibration, and implications for measuring unknown materials on Mars are the subjects of this paper. The major goals of this calibration were both to align the spectrometer to perform accurate elemental analysis and, to derive a matrix of uncertainties that are applied to XRF measurements of all elements in unknown materials. A small set of pure element and pure compound targets and geologically relevant reference materials were measured with the flight hardware in a simulated martian environment. Elemental calibration and quantifications were carried out using PIXL's XRF quantification software (PIQUANT). Uncertainties generated were implemented into the PIQUANT software version employed by the PIXL's data visualization software (PIXLISE). We outline in this work, a list of factors that impact micro-XRF accuracy, the methodology and steps involved in the calibration, details on the fabrication of the uncertainty matrix, instructions on the use and interpretations of the uncertainties applied to unknowns and an assessment on the limitations and areas open to future improvement as part of subsequent calibration efforts.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christopher M. Heirwegh, William Timothy Elam, Yang Liu, Anusheela Das, Christopher Hummel, Bret Naylor, Lawrence A. Wade, Abigail C. Allwood, Joel A. Hurowitz, Les G. Armstrong, Naomi Bacop, Lauren P. O'Neil, Kimberly P. Sinclair, Michael E. Sondheim, Robert W. Denise, Peter R. Lawson, Rogelio Rosas, Jonathan H. Kawamura, Mitchell H. Au, Amarit Kitiyakara, Marc C. Foote, Raul A. Romero, Mark S. Anderson, George R. Rossman, Benton C. Clark III. 2024-02-02. Pre-Flight Calibration of PIXL for X-ray Fluorescence Elemental Quantification. https://arxiv.org/abs/2402.01544

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph

A Green's-function method for vertical thermal boundary conductance in anisotropic multilayers

Vertical thermal interfaces occur in both engineered and natural materials. Their vertical thermal boundary conductance can differ from the horizontal counterpart, requiring dedicated characterization. Yet current thermal metrology resolves vertical thermal boundary conductance only in restricted geometries such as two bulk media, for lack of an efficient forward solution that admits anisotropy, multilayers, and depth-dependent vertical thermal boundary conductance together. We present a Green's-function boundary integral equation (GBIE) method that couples transfer-matrix Green's functions to an interface-only integral equation for depth-dependent $G_v(z)$, supporting dissimilar orthotropic multilayers ($k_x\neq k_y\neq k_z$) on either side and horizontal conductance $G_h$. For anisotropic film-on-substrate multilayers with films from $1~μ\mathrm{m}$ to $100~\mathrm{nm}$, the GBIE agrees with three-dimensional finite element method (FEM) predictions to within one percent mean normalized phase and amplitude error, while running $29\text{--}210\times$ faster and reducing peak memory by factors of $120\text{--}450$ in single-core tests; a JIT-compiled JAX implementation reaches up to $4100\times$ on a matched 16-core comparison. The GBIE further reproduces a continuous film over a buried interface, representative of a thermoreflectance measurement, and a finite-depth interface with depth-dependent $G_v(z)$. The GBIE accommodates lateral-to-film-thickness ratios above $10^{5}$, where volumetric FEM can become computationally prohibitive. These results establish an efficient forward solution for vertical-interface heat transport in systems ranging from microelectronic device sidewalls to grain boundaries in polycrystalline solids.

physics.app-ph