Search arXivSearch

arXiv · 2407.20723

Design of High-speed readout electronics for the DarkSHINE electromagnetic calorimeter

Abstract

The DarkSHINE experiment aims to search for dark photons by measuring the energy loss of the electrons recoiled from fixed-target. Its electromagnetic calorimeter is primarily responsible for accurately reconstructing the energy of the recoil electrons and bremsstrahlung photons. The performance of the electromagnetic calorimeter is crucial, as its energy measurement precision directly determines the sensitivity to the search for dark photons. The DarkSHINE electromagnetic calorimeter uses LYSO crystals to form a fully absorptive electromagnetic calorimeter. It utilizes SiPMs to detect scintillation light in the crystals, and its readout electronics system deduces the deposited energy in the crystals by measuring the number of photoelectric signals generated by the SiPMs. The DarkSHINE electromagnetic calorimeter aims to operate at an event rate of 1-10 MHz, detecting energies ranging from 1 MeV to 1 GeV. To meet the requirements of high energy measurement precision, high event rate, and large dynamic range, we have researched and designed a readout electronics system based on dual-channel high-speed ADCs and a customized DAQ. The front-end amplification part of this system uses low-noise trans-impedance amplifiers to achieve high-precision waveform amplification. It successfully achieves a dynamic range up to a thousandfold through a double-gain readout scheme. The digital part uses 1 GSPS high-speed ADCs to achieve non-dead-time, high-precision waveform digitization. The DAQ part uses JESD204B high-speed serial protocol to read out the signal from ADC, and transmit it to PC software for processing and storage. Test results show a signal-to-noise ratio greater than 66 dBFS and an ENOB greater than 10.6 bits. Energy spectra measurements have been conducted using LYSO crystals and SiPMs, and an energy resolution of 5.96% at the 2.6 MeV gamma peak of Th-232 has been achieved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yihan Guo, Shu Li, Kun Liu, Yang Liu, Yongqi Tan, Jiannan Tang, Weihao Wu, Haijun Yang, Zhiyu Zhao, Wei Zhi, Zhizhen Zhou. 2024-07-30. Design of High-speed readout electronics for the DarkSHINE electromagnetic calorimeter. https://arxiv.org/abs/2407.20723

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mortality of ultra-thin LGADs and PiN diodes from high energy deposition

Low Gain Avalanche Diodes are prime candidates for high-resolution timing applications in High Energy Physics, Nuclear science, and several other fields. Operating these devices in high-radiation environments presents various hazards, including the risk of their permanent degradation or destruction caused by effects such as Single Event Burnout. Studies using minimum ionizing particles found a greatly reduced Single Event Burnout risk by operating below a bias voltage corresponding to an average electric field of 12 V/$μ$m - however, as high energy particle colliders produce a wide energy spectrum of radiation, it is crucial to understand this phenomenon and other possible damage mechanisms at energy deposition levels greater than those of minimum ionizing particles. This was achieved by pre-irradiating LGADs and PiN diodes with active thicknesses of 20, 30, and 50 $μ$m up to 1.5 $\times$ 10$^{15}$ $\mathrm{n_{eq}/cm^2}$, and exposing them to beams of protons and heavy ions (C, O, Fe, Au) at the BNL Tandem van de Graaff accelerator. Several mortality categories were observed, defined by different electrical and mechanical damage signatures. This furthers our understanding of permanent radiation damage of silicon devices, crucial towards mitigating Single Event Burnout and other damage mechanisms to safely operate future detectors.

physics.ins-det

Small but Tubby: A Magnetic Loop Antenna Made from 100 mm Copper Tubing

This paper presents the electrical model, key equations, and practical construction of a small transmitting magnetic loop antenna built from unusually large 100 mm diameter copper tubing. The large conductor surface area and wide-area transitions to the vacuum capacitors were designed to minimize resistive losses. The frequency range from 1.8 MHz to 31 MHz is unusually wide. Frequency, impedance matching, and azimuth are all adjusted automatically by servo motors. Indoor losses originate predominantly from near-field coupling to the environment rather than from the antenna itself. Temperature-rise measurements confirm that the bulk of the dissipated power is absorbed by the environment, not by the antenna components. The conducted H-field measurements demonstrate good agreement between the measured H-field and the theoretical free-space H-field calculated from the antenna geometry and an estimated loop current. The loop current was estimated from the measured antenna bandwidth and the applied transmit power. The antenna was developed for indoor operation where outdoor installation is not possible.

physics.ins-det

Construction and characterisation of the DarkSide-20k veto silicon photo-multiplier tiles

Silicon photo-multipliers (SiPMs) are state-of-the-art sensors capable of detecting a single photoelectron under cryogenic conditions, with potentially lower radioactivity than widely used photomultiplier tubes. The DarkSide-20k experiment, designed to perform direct dark matter searches using liquid argon as the target material, employs SiPM technology to detect interactions in the active detector volumes, including the central dual-phase Time Projection Chamber and the Inner and Outer Veto volumes. The vetoes are designed to discriminate against radiogenic neutron and cosmic muon backgrounds associated with the dark matter search. This paper describes the completed production and test protocols for the "Veto Tiles" (called vTiles, arrays of 24 SiPMs integrated on a printed circuit board providing the power distribution and signal amplification); 16 vTiles are grouped into "Veto Photo-Detector Units" to instrument the Inner Veto volume. Each vTile underwent detailed testing at room and cryogenic temperatures, confirming stable operation, high signal-to-noise ratio, and low radioactive contamination, demonstrating the robustness of the proposed design for cryogenic conditions. The final production yield exceeded 87%, surpassing the 80% requirement and corresponding to 1920 Veto Tiles to populate 120 Veto Photo-Detector Units, plus an additional 6% as spares.